Nominal filtration rating: 0.01 m [Filtration efficiency: 99.9%] Oil mist density at outlet: Max. 0.01 mg/m3 (ANR) [0.008 ppm] Cleanliness at outlet: Not more than 35 particles of size 0.3 m or larger/10 l (100 particles or less/ft3) 3/8, 1/2 1,000 Piping support type 450C AME 1/2, 3/4 2,000 550C 3/4, 1 3,700 1, 1 1/2 650 6,000 1 1/2, 2 850 12,000 AME150C to 550C AME650/850 150C 1/8, 1/4
(2-color indication) Yes 12 V 24 V 2-wire Grommet Water resistant (2-color indication) With diagnostic output (2-color indication) Magnetic field resistant (2-color indication) IC circuit 5 V, 12 V 4-wire (NPN) P5DW 2-wire Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto
(Value in the initial stage) Solenoid Specifications Internal pilot VZ SYJ712 4 SYJ72 2 4 (A) 2 (A) 2 VS 1 (P) 3 (R) 1 (P) 3 (R) External pilot Grommet (G) (H), L plug connector (L), M plug connector (M) Electrical entry SYJ71 R 2 4 SYJ72 R 2 4 Coil rated voltage (V) DC 24, 12, 6, 5, 3 100, 110, 200, 220 (A) 2 (A) 2 AC50/60Hz X X Allowable voltage 10% rated voltage 0.5 (With light: 0.55)
75E IDUmE-m-L With a motor type auto drain*2 IDF4E to 75E IDFmE-m-M p. 30 IDF190D, 240D IDFmD-m(-m)-M IDU3E to 75E IDUmE-m-M With a metal name plate IDF100F to 150F IDFmF-m-P p. 30 IDF4E to 75E IDFmE-m-R Refrigerant R407C (HFC) IDF D p. 31 IDF100F to 150F IDFmF-m-R With an earth leakage breaker IDF190D to 370D IDFmD-3-R IDU3E to 75E IDUmE-m-R Power supply terminal block connection IDF1E
Common/VX31 4, 32 4, 33 4 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 Grommet: G Conduit: C DIN connector: D Conduit terminal: T VX VNl VQ B Measurement for connection H J K L M L M L M L M N N Grommet Conduit DIN connector Conduit terminal Electrical entry Port size P Rc(PT) A C D E F Model 22.5 B1 B2 18 21 21 20 20 20 74.5 90 98 30 35 40 19 25 25 20 23 25.5 29 32 32 14.5 17 17 6 7.5 7.5 23 25.5 28 46.5
Standard Type: CXS Vertical mounting L L Mounting orientation m m up to 300 up to 400 up to 700 ( up to 800) up to 200 up to 600 up to 100 Max. speed (mm/s) Stroke (mm) All strokes 1 2 6 10 15 Selection graph 3 4 5 6 20 25 32 Horizontal mounting L Mounting orientation m m Refer to the caution notes below.
2 @1 @3 e u o t @2 !8 @0 @0 @3 !2 !9 e @0 @1 o t u !8 @0 @2 !1 !4 q w r y !5 !6 i w i !
(M) -45D (M) x 110L 110 135 x 135L -50D (M) -50D (M) x 115L 115 140 x 140L -75D (M) -75D (M) x 140L 140 165 x 165L -100D (M) -100D (M) CHQWB100-10D (M) x 165L 165 190 x 190L CHQWB40-5D (M) CQ-M5 x 75L CQ-M10 x 105L 75 105 -15D (M) -10D (M) x 80L 80 x 110L 110 -20D (M) -15D (M) x 85L 85 x 115L 115 -25D (M) -20D (M) x 90L 90 x 120L 120 -30D (M) -25D (M) x 95L 95 x 125L 125 -35D (M) -30D (M
0 . 8 , M 6 x 1 Nr4 x 0.7, N,ls x 0.8 s1O-s16 M 5 x 0 . 8 , M 6 x 1 Mls x 0.8, M6 x 1 a20-a32 M6 x 1, M8 x 1 M5 x 0.8, M6 x 1, M8 x 1.25 ..aAO=s5O', M 6 x 1 , M B x 1 M 6 x 1 , M 8 x 1 . 2 5 \4q,r'tirc How to Order ) ZPY Pad dia.
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
From this figure, subtract 1.63kg, the weight of the moving parts (refer to the weight table above), to obtain 9.37kg, which is the maximum load weight. ua M M+m 2 u=1.4ua u Ek= 2 Ek : Kinetic energy (J) M : Weight of driven object (kg) m : Weight of cylinder moving parts (kg) u : Max. speed (m/s) ua: Average speed (m/s) Note) In the case of horizontal applications, make sure that the load
0.34 0.25 0.50 0.25 0.50 0.34 0.53 0.34 B 0.66 0.41 Through screw clearance hole / NC(D)Q8N(Z)S T (Inch) Symbol Bore E 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.20 0.25 0.25 0.34 0.34 0.41 43 Series NCQ8 Dimension Both ends tapped NC(D)Q8A-(C)(M) NC(D)Q8WA-(C)(M) NC(D)Q8A-S(M) NC(D)Q8A-T(M) Both Ends Tapped (Inch) O1 R Bore size Remarks R R O1-Thread 056 (
0 . 8 , M 6 x 1 Nr4 x 0.7, N,ls x 0.8 s1O-s16 M 5 x 0 . 8 , M 6 x 1 Mls x 0.8, M6 x 1 a20-a32 M6 x 1, M8 x 1 M5 x 0.8, M6 x 1, M8 x 1.25 ..aAO=s5O', M 6 x 1 , M B x 1 M 6 x 1 , M 8 x 1 . 2 5 \4q,r'tirc How to Order ZPY Pad dia.
Example) Air filter + 2 port valve Hexagon socket Uni 1/8 to 1/2 2 port valve Modular adapter (E310-U02) Spacer with bracket (Y300T-A) Air filter (AF30-A) Front matter 5 Air Combination Air Filter + Regulator + Lubricator AC20-A to AC40-A JIS Symbol 2 1 L How to Order AC A 30 03 DG Option/Semi-standard: Select one each for a to m.
Obtain the actual moment of inertia ). ) = )1 + )2 m1, m2: Mass of load 1 and 2 r1, r2: Radius of load 1 and 2 L: Distance from the shaft to the center of gravity of load 2 Calculation Example m1 = 2.5 kg, m2 = 0.5 kg, r1 = 0.1 m, r2 = 0.02 m, L = 0.08 m 0.12 )1 = 2.5 x = 1.25 x 10-2 kgm2 2 0.022 )2 = 0.5 x + 0.5 x 0.082 = 0.33 x 10-2 kgm2 2 ) = (1.25 + 0.33) x 10-2 = 1.58 x 10-2 kgm2 Front
CN2 7 8 MX MXR 3 MR 2 4 MRR LG PE M (4) CN2L 7 8 MX2 MXR2 3 MR2 2 4 MRR2 LG 1. , 2. 3. 3.8.3 4.
4-16 Side entry Top entry Side entry U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable Without cable (2) Max. 16 stations (2) Max. 16 stations (2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J
Note 2) Not possible with bronze elements. 20 Port size Rc 2 Symbol Nominal filtration accuracy (m) Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 50 70 74 75 100 105 120 Symbol Element category X50 001 002 005 010 020 040 050 070 074 075 100 105 120 Material Element type 2 3 Bronze B S T G H P M L Sintered metal Stainless steel Polypropylene Glass fiber Cotton Cotton Stainless steel
Note 2) Not possible with bronze elements. 20 Port size Rc 2 Symbol Nominal filtration accuracy (m) Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 50 70 74 75 100 105 120 Symbol Element category X50 001 002 005 010 020 040 050 070 074 075 100 105 120 Material Element type 2 3 Bronze B S T G H P M L Sintered metal Stainless steel Polypropylene Glass fiber Cotton Cotton Stainless steel
The standard lead wire length of solid state switches with timer, water resistant 2-color indication type, wide range detection type or heat resistant 2-color indication type is 3 meters in length. (0.5 m is not available.) Lead wire lengths of 3 m and 5 m are standard for magnetic field resistant 2-color indicator type solid state switches. (0.5 m is not available.)