AMR3000 AMR4000 AMR5000 AMR6000 Model Model name Bracket 13576 13556 13587 13568 (5)(6) G36-1001 G46-1002 Pressure gauge 1.0 MPa Accessory (Option)/Part No.
B C D E F G H I J K L M N O P Symbol Model A ITVH ARM2500 ARM3000 6 17 44 56 42 126.5 58 45 17 21 38 42 29 48 68 33.5 ITVX 7 21 54 68 55 153.5 70 53 23.5 27.5 48.5 55 35 59 85.5 42.5 PVQ Manifold stations Dimensions by the Number of Stations 10 Model Symbol VY1 9 8 7 6 5 4 3 2 L1 454 412 370 328 286 244 202 160 118 VBA VBAT ARM2500 L2 442 400 358 316 274 232 190 148 106 L3 420 378 336 294
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.)
For Flow Control Equipment Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on the SMC website, http://www.smcworld.com Tubing O.D. 6, 8, 10 6 8, 10 8 10, 12 10 12 C values: Sonic conductance dm3/(sbar) Free flow 0.6 1.1 1.2 1.6 2.2 4.2 4.4 Controlled flow 0.7 1.1 1.3 2.2 2.6 4.4 4.8 Free flow 0.2 0.3 0.3 0.2 0.2 0.3 0.3 b values: Critical pressure ratio
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 7) : For thread type, NPT only.
Two switch spacers are included with the product with built-in magnet. 906 Rotary Actuator 11-CRA1-Z Dimensions: Basic Type, 11-CRA1S30 Size: 30 Single shaft Double shaft 75 10 8 6 0 0.2 8 (g6) 7.8 0 0.2 28 Auto switch 8 x M5 x 0.8 depth 6 (Opposite side 4 locations) 28 40 4 x 6 (Mounting hole) 9 16 0 0.1 8g6 9.2 14 3 M5 x 0.8 (Vacuum suction port) 0 0.025 3 2 x Cushion valve (Width across
Use within the operating temperature range. 6. The actuating piston chamber and the bellows chamber are directly connected to atmosphere. Use in an environment where dust emissions will not cause problems. (Please consult with SMC if the release of dust must be avoided.) 7.
6 with a torque of 0.3 Ncm. XSA XVD XVD Remarks 1: The feeding of the main air supply is carried out with the initial air supply pilot valve port S !9 in a pressurized state. 2: Increasing the initial air supply amount in the mechanism will cause a decrease in the range of the main air supply amount.
[MPa] ZH30-X185 ZH40-X185 ---7 ---7 3,500 5,000 Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] 4,500 ---6 ---6 3,000 Discharge flow rate 4,000 Discharge flow rate Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure Vacuum
Example of Selection from Minimum Operating Flow 100 Example) Vacuum saving valve used: ZP2V-A8-05 From Table 1, Q2 can be calculated as 5.0 l/min (ANR). 90 31 {l/min (ANR)} 5 {l/min (ANR)} 80 N = 6 (unit) Vacuum pressure (kPa) 70 Q2 = 5.0 l/min (ANR) 60 Table 1.
Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, pages 14-14-6 to 8 for Precautions on every series, and pages 14-20-62 to 64 for more detailed precautions on every series. Misc.
Option Bracket J: With drain guide (Option) female thread T: With element service indicatior Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35
6 7 7 139 152 158 184 190 13 13 16 16 19 55 66 72 92 98 63 76 76 90 90 63 76 76 90 90 10 10 10 10 10 1 4 3 8 , AMF250 1 2 3 8 1 2 , AMF350 3 4 14-20-46 6 Odor Removal Filter Series AMF Dimensions AMF450 to AMF850 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket
6 7 7 9 9 9 11 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 10 10 10 10 10 10 10 10 10 1 8 1 4 3 8 AMG150 , , 1 4 3 8 , AMG250 1 2 3 8 1 2 , AMG350 3 4 1 2 3 4 , AMG450 1 1 1 1 AMG550 AMG650 3 4 1 2 , , 14-20-6 5 Water Separator Series AMG Dimensions
6 !7 @0 !8 @1 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CS2Y. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) CS2Y125A-PS 125 140 160 CS2Y125A-PS CS2Y140A-PS CS2Y160A-PS !6 !7 !8 19 @0 21 Without cushion Consists of component part numbers !6, !
Cylinder with Lock/Double Acting, Single Rod Series CNS 125, 140, 160 Replacement Procedure is P.356 Construction $6 %1 $9 %4 %7 $7 $9 %3 %6 %2 %0 $8 %5 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CNS. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no.
6 !7 !4 !9 !3 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series MY1H. *BLUE links will lead to purchase pages. Call or email us at sales@smcpneumatics.com for request. Replacement Parts: Seal Kit Description Qty. Note MY1H10 No. 13 Seal belt MY10-16AStroke 1 14 !6 !7 !8 !9 Dust seal band MY10-16BStroke 1 13 and 14 are not included in the seal kit.
6, Outer Diameter (3rd Core): 6, Outer Diameter (4th Core): 6, Outer Diameter (5th Core): -, Inner Diameter (2nd Core): 4, Inner Diameter (3rd Core): 4, Inner Diameter (4th Core): 4, Inner Diameter (5th Core): -, Coil Winding Length(m): 10, Specification: Made-to-Order Product, Maximum operating pressure(MPa): 0.8 (at 20°C), Operating Temperature(°C): -20 to +60
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter: 2mm , Power-saving circuit available, 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter: 2mm , Power-saving circuit available, 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm