Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.

Never use in an atmosphere of explosive gases. The structure of switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Mount switches in locations without vibration (98m/s or less) or impact (490m/s or less). 3. Do not use in an area where surges are generated.

Add an asterisk () at the beginning of electro-pneumatic regulator part numbers to be mounted.

Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5m or finer. 19 - 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.

Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5m or finer. 18 - 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.

An application which could have negative effects on people, property, or animals requiring special safety analysis. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 2.2 Installation 2 2 IDF100F~150F-W IDX-OM-M051 Air Dryer 2.

The most typical is an increase in outlet pressure as the inlet pressure decays often stated as a given rise per a given drop in pressure. [Inboard leakage] Leakage rate from outside to inside of the products occurring when an internal pressure is less than the external pressure.

option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 195 Thermo-chiller Basic Type HRSE Series Circulating Fluid Temperature Controller Circulating Fluid Line Equipment Circulating Fluid Line Flow Switch Fittings and Tubing Circulating

Switching of valve is based on an electric signal from the connector. The valve coil is kept in a de-energized state even when there is an electric signal from the connector.

(Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.Options to select continuous monitoring or monitoring during operation are available. Also, the detection start time after the start of operation and the detection end time can be set.

Mixed single and double wiring is available as an option.

You have an option of either a red or gresn risinq pin on your indlcator. @ aDE IXITtENS|ONS HOW TO ORDER PART NO. suFFtx No.

If the power should not come back on, please contact SMC for an inspection.

Our pressure switches do not have an explosion proof rating. Never use it in the presence of an explosive gas as this may cause a serious explosion. Panel Caution Panel mounting adapter A Panel mounting adapter B 1. Do not use in an environment with spattering liquid of oil or solvent. 2.

Never use in an atmosphere of explosive gases. The switches do not have an explosion proof rating. Never use in the pressure of an explosive gas as this may cause a serious explosion. Maintenance Warning Mounting 1. Perform a periodical inspections for proper operation of the switch. Unexpected malfunctions may cause possible danger. 2.

N o t e 3 ) F.P. and S. kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. K I TE L E C T R I C A L E N T R YC A B L E L E N G T H Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 !

progrom is an impoftant pafi rl tltis suppllchain s-vstem. The progrant identiJies product series and options that are cornmonly used in the local market.

In addition, it can relay output as an alarm contact output when an alarm is generated. Alarm Alarm code Alarm description Operation status Main reason AL0 Memory error Stop There is an abnormality with the memory data in the controller due to a high level of noise. AL1 Controller error Stop There is an abnormality with the data in the controller due to a high level of noise.

Accessories Sold Separately/ International Standard The assembly consists of an A and B bracket and 2 mounting screws.