Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Note 1) CM2□M cylinders with stable lubrication function and CM2-XC92 cylinders have the same dimensions as those of the standard product.
Note 2) CQ2□M and CQS□M cylinders with stable lubrication function can only be selected for the type with a built-in magnet. In addition, the rubber bumper cannot be selected.
(a)(a) (b) (ZS-46-B) +(ZS-46-D) 90 -16No.PS-OMU0005CN-C (-M5) 1/6~1/4 1~1.5Nm (ZS-46-N) -01-N01 23 3~5 Nm -C4L-C6L 1/61/4 1~1.5Nm -17No.PS-OMU0005CN-C -18No.PS-OMU0005CN-C () TU0425( 42.5) -19No.PS-OMU0005CN-C FG -20No.PS-OMU0005CN-C Z/ISE20B(F)-S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -X () -S/-R () NPN 2 Max.28 V80
(max. 20 stations) 3 SX3000 5 SX5000 Connector mounting position Symbol Mounting position U U side D D side Valve stations A, B port size Note Symbol 02 Stations SX3000 SX5000 2 stations Port size 4 One-touch fitting 6 One-touch fitting Mixed Symbol Port size 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting Mixed Symbol C4 C6 M Double wiring specification C4 C6 C8 M 08 02 8 stations
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
Usable stroke by buckling strength Usablestroke by Mounting style buckling strength (cm) Pressure Symbol and sketch (MPa) Symbol of bracket Rod side Frang e F Head side flange 103 92 113 Foot: 79 70 86 L G 66 58 72 45 38 47 33 27 34 26 22 27 96 83 106 Center Clevis trunnion 71 61 76 CD T 59 50 62 135 119 147 101 89 111 84 74 91 Rod side Frang e F Head side flange 301
Rated Flow Range: 11 [2 to 100 (50) L/min], Port Size: Rc1/4, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V, Unit Specification: Fixed SI Unit, Operation Manual: Japanese and English, Calibration Certificate: None, Lead Wire: Lead Wire w/Connector, Rubber Cover, Option: Bracket
Rated Flow Range: 25 [0.5 to 25 (12.5) L/min], Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V, Unit Specification: Fixed SI Unit, Operation Manual: Japanese and English, Calibration Certificate: None, Lead Wire: Lead Wire w/Connector, Rubber Cover, Option: Bracket
Actuators 1 Cylinder inspection items Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters The following describes the general contents of the cylinder inspection items. Actually, add inspection items suitable for the customers specifications and perform
Actuators 2 Troubleshooting The following describes the general contents of the troubleshooting. [Cylinder] Cause Corrective action Trouble (Symptom) The operation is not smooth. The output drops. The cylinder does not operate. The grease of the sliding part runs out. Apply the grease. The following may be the cause of the trouble. As water content, such as drain enters, the grease flows
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
11.5Nm 2) RNPT 23 R,NPT Nm EXH.
How to order: EX500-AP 050 S How to order: EX500-AC 030 SSPS How to order: EX500-AC000-S 1 How to order: EX9-AC 010 1 How to order: EX9-AP 010 7 Cable length (L) Connector specification 003 0.3 [m] 005 0.5 [m] 010 1 [m] 030 3 [m] 050 5 [m] Cable length (L) Connector specification 010 1 [m] 050 5 [m] Cable length (L) 010 1 [m] 030 3 [m] 050 5 [m] Cable length(L) 010 030 1[m] 3[m] S Straight
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L ISE30 01 25 M For positive pressure ZSE30 01 25 M For vacuum/low pressure Option 2 Piping specifications Nil None Bracket R 1/8 (With M5 female thread) 01 NPT 1/8 (With M5 female thread) A T1 Straight type 4 One-touch