SMC Corporation of America
Elite Part Number Search
Search Results "PVQ31-6G-16-01F"

Table inside and outside diameters For alignment of rotation center and work piece High precision type: MSQA H8/h8 Positioning pin hole Hollow axis Accommodates wiring and piping for equipment mounted on the table Positioning pin hole For position of rotation direction Rolling bearing Hollow axis Basic type MSQB Size Hollow axis 1 3.5 2 3.8 3 5 7 6 Size Hollow axis 10 5 20 9 30 9 50 10 70 16

Rc 1/16 gauge port 2-4.5 Mounting hole Connection mark All types are the same in terms of connection.

1 q t i 16-11-40 5 Series PF2D Digital Flow Switch For Deionized Water and Chemicals Dimensions: Separate Type Sensor Unit PF2D504-11/520-13 Internal circuit and wiring example 60 70 176 z to , are terminal numbers.

Panel mount adapter + Front protective cover Note) These options are unassembled in the factory, but are included with the shipment. 16-3-36 5 Series PSE300 Controller Specifications Conforms to CE marking and UL (CSA) standards.

(Refer to Precautions on page 16-2-24 for details.)

SE1-ll-16, -17 I Z PFor swich type "-16" or "-17", rotating SET1 will adjust ON setting for OUT1 (Black lead wire, Red LED) and SET2 will adjust ON setting for OUT2 (White lead wire, Green LED).

16 13 11 15 16 25 mm2 VQD P A P B A EA B EB VFS Air exhaust side eff area S (P2=0.5MPa) 18 mm2 VS Note 1) Maximum operating pressure of solenoid valve is 0.9 MPa.

stations) 1 to 12 stations (16 stations) 24 1 to 12 stations (16 stations) 24 1 to 12 stations (16 stations) 24 1 to 10 stations (16 stations) 20 EX250-SPR1 EX250-SDN1 Note 2) T kit 1 to 12 stations (16 stations) 24 EX250-SDN1-X102 Note 3) 1 to 4 stations (8 stations) 1 to 2 stations (4 stations) 1 to 4 stations (8 stations) 1 to 2 stations (4 stations) 8 4 8 4 EX250-SAS3 EX250-SAS5

N.C. 3 2 1 19 2 x 3.5 Mounting hole (16) 11 24.5 21 12 Plug IN port 5 (Lead wire length) 27 LVM10R4 36 300 16 13 UL1007 AWG22 1 2 3 N.C. N.O. (16) (16) 11 OUT port IN port 10 Push type Manual override 73.5 LVM10R6 N.O. N.C. 3 2 1 25.5 (16) N.O.

16-Bit) and output pressure> Set pressure 0x0 0x0FFF Output pressure 0% 100% Input data shall be entered from Bit 0 to Bit 12 of the 16-Bit process data (2 BYTE). (When F_1=0%F.S. and F_2=100%F.S.) (Ex.) When the output pressure is 100%, the set pressure value is 0x0FFF.

Contents 10 MXP10-PS 12 2 pieces of No.19 MXP12-PS 16 MXP16-PS MXPJ6 Description Material Note Parts list No.

I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10 15.5 1.5 1.6 13 23 14 25 36 16 25 37 16 24 36 32 40 65 31 39 64

O.D. 6 KFE06-02 KFE08U-03 KFE08N-03 KFE10U-03 KFE10N-03 KFE12U-03 KFE12N-03 4 5 6 6.5 7.5 8 9 1 4 41 49 50 63 62 93 91 37.5 17 12 17 44.2 16 15.2 3 4 5 5.5 6.5 7 8 M10 x 1 11 6 11 17 21 30 35 45 13 8 M12 x 1 3 8 17 46.2 39.5 16.2 19 14 19 3 8 M15 x 1 16 10 17 48.8 41.5 18.8 19 17 22 Connection thread Applicable tubing Mounting plate thickness 4 mm or less 18 12 3 8 17 51.3 44.5 19.3 22 19

Torque/Allowable Number of Rotations 5 32 1 4 5 16 3 8 Applicable tubing O.D

130 16 180 16 Maximum pump head [m] 50 49 55 49 68 49 Settable pressure range5 [MPa] 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55 0.10 to 0.49 0.10 to 0.68 0.10 to 0.49 Minimum operating flow rate6 [L/min] 20 2 25 2 40 2 Tank capacity [L] 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric conductivity setting range [S/cm] 0.5 to 45.0 0.5 to 45.0 0.5 to 45.0 Circulating fluid system

Flow Rate and Effective Area AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values

TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0

Weight (g) D-A53 D-A54 D-A56 D-A64 D-A67 Auto switch model 0.5 m (Nil) 3 m (L) 5 m (Z) 24 48 96 24 48 24 48 Lead wire length Dimensions (mm) 6 14 6 4.5 5 12 22 Indicator light 12 33 D-A64/A67 without indicator light DD4 16 11 16 Most sensitive position 1639 Reed Auto Switch Tie-rod Mounting Style D-A33C/D-A34C/D-A44C Refer to SMC website for the details of the products conforming to the

For details, refer to page 10-20-40. 10-12-16 16 10-12-17 17 Stroke Reading Cylinder Series CE1 12, 20, 32, 40, 50, 63 How to Order CE1 32 200 L J79W Number of auto switches Mounting style Auto switch B L F G D Both ends tapped style (Standard) Bore size Nil Without auto switch Nil 2 pcs.

O-ring 16 NBR For 90 (Top view from long shaft side) For 100 (Top view from long shaft side) A port B port A port B port (Long shaft side) Component Parts Parallel key for size 40 Note Description Material No.