30, 35, 40, 45, 50, 75, 100 Note ) Consult with P/A regarding the manufacture of strokes other than the above.
Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.
Setting Position (mm) D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, A34 D-A44 D-B5 D-B6 D-H7l D-H7C D-G5NTL D-H7lW D-H7lF D-H7BAL D-B59W Bore size (mm) A B A B A B A B A B A B A B 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 25 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5 58.0 35.5 55.0 32.5 57.0 34.0 56.5 33.5 53.0
Symbol Bore size (mm) H A L1 H1 Y type double knuckle I type single knuckle 125 140 160 Y-12 110 50 100 156.5 I-12 Y-14 110 50 105 161.5 I-14 Y-16 120 56 110 170.5 I-16 L1 H1 A, H Dimensions When Mounting a Single/Double Knuckle Joint together with a Rod End Nut A H Bore size (mm) 125 140 160 65 125 65 125 76 140 Single knuckle joint and double knuckle joint should be used separately.
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact P/A regarding other voltages.
If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.
Applicable cylinder MY1B25 MY1B32 MY1B40 75 84 105 A B MY-S25 35 50 8 11.7 5 6 9.5 5.5 M6 x 1 MY1H A B MY-S32 45 64 11 6.6 M8 x 1.25 MY1 HT Side supports consist of a set of right and left supports. MY1 W Guide to Side Support Application MY2C For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load.
Connect the plug of the AC cord*1 to a commercial power outlet with a ground terminal (100 to 240 VAC, 50/60 Hz). Ensure the ground terminal is correctly connected. The ground terminal is connected to the frame ground (F.G.) of this product.
Symbol Bore size (mm) 125 140 160 H A L1 H1 3.5 Y type double knuckle I type single knuckle Y-12 110 50 100 156.5 I-12 Y-14 110 50 105 161.5 I-14 Y-16 120 56 110 170.5 I-16 L1 H1 A, H Dimensions When Mounting a Single/Double Knuckle Joint together with a Rod End Nut A H Bore size (mm) 125 140 160 65 125 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-
26 29.5 37.5 K 5 3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21 AC31 AC41 * Without relief valve option ** With relief valve option mm AC-A A* 90 117 154 AA** 140 181 238 B 160 220 239 C 73 86 92 E 30 38 F 45.5 58.5 75.5 G 40 55 80 J 26 29.5 37.5 K 5 3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21A AC31A AC41A * Without relief valve
M5 x 0.8 Port B 4-M4 x 0.7 depth 6 I N J E A D P A A M N 2 R SMC R E O P P T 6 A I R R G Y R A I 18 6 21 9 5 5 23 34 Side A Side B 12-11-13 14 Series MRHQ Dimensions MRHQ16 A B 41 50 66.5 4-M5 x 0.8 depth 8 30 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0 -0.062
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
/60 Hz) 4.2 A 10 A 180/200 W 50/60 Hz 220 W 0.01 m (99.9% filtration efficiency) Particles of 0.3 m or more: 3.5 particles/L [ANR] or less Heater operation, PID control Singlephase 200 VAC (50/60 Hz) 2.1 A 5 A Singlephase 230 VAC (50/60 Hz) 2.1 A 5 A Singlephase 100 VAC (50/60 Hz) 9.4 A 15 A Singlephase 200 VAC (50/60 Hz) 4.8 A 10 A Singlephase 230 VAC (50/60 Hz) 4.8 A 10 A Power supply Note
Auto switch model Bore size [mm] 20 25 32 40 D-M9m(V) D-M9mW(V) BM8-020 (A set of a, b, c, d) BM8-025 (A set of a, b, c, d) BM8-032 (A set of a, b, c, d) BM8-040 (A set of a, b, c, d) BM8-025S (A set of a, b, c, d) * S: Stainless steel set screw BM8-032S (A set of a, b, c, d) * S: Stainless steel set screw BM8-040S (A set of a, b, c, d) * S: Stainless steel set screw D-M9mA(V) BM8-020S (A
(Non-locking) 55.5 [62] 43.1 36.5 25.5 49 A A 19 9.5 21 (Pitch) n-Rc (PT)1/8 P=17 21 (A port) A A 19 9.5 18.5 (Pitch) n-M5 X 0.8 P=16 16 (A port) [ ] for AC Other dimensions are the same as the M5.
B A B A B A PB PB Double acting N.C. N.O. N.O. Double acting Double acting With flow rate adjustment PA PA B A PB B A N.C. Double acting With bypass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. B A PB B A Double acting N.C. Double acting With indicator PA N.C. B A N.C. Manifold (5 stations max.)
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
Y: 4.5 to 7 D: 6 to 8 50 37.5 2(A) 2(A) 11 (A port) Rc 1/4 Stations L L1 L2 Formula 2 83.5 68.5 3 111 96 5 166 151 7 221 206 9 276 261 4 6 8 10 : With light/surge voltage suppressor ( ): Dimensions for external pilot L1 = 27.5 x n + 28.5 138.5 193.5 248.5 303.5 L2 = 27.5 x n + 13.5 123.5 178.5 233.5 288.5 4-8-13 Dimensions: VV3P5 (For N.C.)
Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. 16-2-25 2 Pressure detection for a wide range of fluids.
of arm section) L1 = 50 [mm] L2 = 40 [mm] a m L2 Item Load factor n Note zLoad mass 1 = m/mmax = 0.5/5 = 0.1 Investigate m.