10 10 10.1 20.1 5.1 1.1 0.1 20.1 10.1 5.1 1.1 0.2 Speed (mm/s) Speed (mm/s) 50 50 2.1 4.1 1.1 0.3 0.1 4.1 2.1 1.1 0.3 0.1 100 100 1.1 2.1 0.6 0.2 0.1 2.1 1.1 0.6 0.2 0.1 For transfer load of 3kg Positioning time (sec) Positioning distance (mm) 100 50 10 1 200 10 10.1 5.1 1.1 0.2 20.1 Speed (mm/s) 50 2.1 1.1 0.3 0.1 4.1 100 1.1 0.6 0.2 0.1 2.1 Refer to page 302 for acceleration time. 223 16
" 1/4" 5/16" 5/16" 3/16" 5/16" 3/16" 5/16" 3/16" 3/16" 1/2" 3/16" 1/2" 3/16" 1/2" 12.7 NPT 1/8 23.4 27.4 39.8 45.8 17.6 14.3 NPT 1/4 25.4 31.4 39.8 45.8 17.6 12.7 NPT 1/8 26.7 30.7 45.3 52.8 24.4 14.3 NPT 1/4 28.7 34.7 45.3 52.8 24.4 17.5 NPT 3/8 30.4 36.7 45.3 52.8 24.4 17.5 NPT 1/4 33.8 39.8 49.6 55.6 30 17.5 NPT 3/8 35.5 41.8 49.6 55.6 30 22.2 NPT 1/2 37.6 45.8 49.6 55.6 30 15-13-4
L dimension 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 VZ 285.5 21 273 No.
Table inside and outside diameters For alignment of rotation center and work piece High precision type: MSQA H8/h8 Positioning pin hole Hollow axis Accommodates wiring and piping for equipment mounted on the table Positioning pin hole For position of rotation direction Rolling bearing Hollow axis Basic type MSQB Size Hollow axis 1 3.5 2 3.8 3 5 7 6 Size Hollow axis 10 5 20 9 30 9 50 10 70 16
Rc 1/16 gauge port 2-4.5 Mounting hole Connection mark All types are the same in terms of connection.
1 q t i 16-11-40 5 Series PF2D Digital Flow Switch For Deionized Water and Chemicals Dimensions: Separate Type Sensor Unit PF2D504-11/520-13 Internal circuit and wiring example 60 70 176 z to , are terminal numbers.
Panel mount adapter + Front protective cover Note) These options are unassembled in the factory, but are included with the shipment. 16-3-36 5 Series PSE300 Controller Specifications Conforms to CE marking and UL (CSA) standards.
(Refer to Precautions on page 16-2-24 for details.)
SE1-ll-16, -17 I Z PFor swich type "-16" or "-17", rotating SET1 will adjust ON setting for OUT1 (Black lead wire, Red LED) and SET2 will adjust ON setting for OUT2 (White lead wire, Green LED).
16 13 11 15 16 25 mm2 VQD P A P B A EA B EB VFS Air exhaust side eff area S (P2=0.5MPa) 18 mm2 VS Note 1) Maximum operating pressure of solenoid valve is 0.9 MPa.
stations) 1 to 12 stations (16 stations) 24 1 to 12 stations (16 stations) 24 1 to 12 stations (16 stations) 24 1 to 10 stations (16 stations) 20 EX250-SPR1 EX250-SDN1 Note 2) T kit 1 to 12 stations (16 stations) 24 EX250-SDN1-X102 Note 3) 1 to 4 stations (8 stations) 1 to 2 stations (4 stations) 1 to 4 stations (8 stations) 1 to 2 stations (4 stations) 8 4 8 4 EX250-SAS3 EX250-SAS5
N.C. 3 2 1 19 2 x 3.5 Mounting hole (16) 11 24.5 21 12 Plug IN port 5 (Lead wire length) 27 LVM10R4 36 300 16 13 UL1007 AWG22 1 2 3 N.C. N.O. (16) (16) 11 OUT port IN port 10 Push type Manual override 73.5 LVM10R6 N.O. N.C. 3 2 1 25.5 (16) N.O.
Contents 10 MXP10-PS 12 2 pieces of No.19 MXP12-PS 16 MXP16-PS MXPJ6 Description Material Note Parts list No.
I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10 15.5 1.5 1.6 13 23 14 25 36 16 25 37 16 24 36 32 40 65 31 39 64
O.D. 6 KFE06-02 KFE08U-03 KFE08N-03 KFE10U-03 KFE10N-03 KFE12U-03 KFE12N-03 4 5 6 6.5 7.5 8 9 1 4 41 49 50 63 62 93 91 37.5 17 12 17 44.2 16 15.2 3 4 5 5.5 6.5 7 8 M10 x 1 11 6 11 17 21 30 35 45 13 8 M12 x 1 3 8 17 46.2 39.5 16.2 19 14 19 3 8 M15 x 1 16 10 17 48.8 41.5 18.8 19 17 22 Connection thread Applicable tubing Mounting plate thickness 4 mm or less 18 12 3 8 17 51.3 44.5 19.3 22 19
Torque/Allowable Number of Rotations 5 32 1 4 5 16 3 8 Applicable tubing O.D
130 16 180 16 Maximum pump head [m] 50 49 55 49 68 49 Settable pressure range5 [MPa] 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55 0.10 to 0.49 0.10 to 0.68 0.10 to 0.49 Minimum operating flow rate6 [L/min] 20 2 25 2 40 2 Tank capacity [L] 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric conductivity setting range [S/cm] 0.5 to 45.0 0.5 to 45.0 0.5 to 45.0 Circulating fluid system
Flow Rate and Effective Area AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values