.: 2 and 4) Max. load current 80 mA Max. impressed voltage 30 V (NPN output) Residual voltage 1 V or less (80 mA load current) Response time 2.5 ms (Chattering-proof function working: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms selectable) Short circuit protection Provided Repeatability 0.5%F.S.

(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 end 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.

Enclosure IP65 Operating temperature range 0 to 50 oC (No freezing and condensation) Environment Operating humidity range Operation, Storage: 35 to 85% R.H. ( No condensation) Withstand voltage 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.

Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -41No.EX-OMP0013-E Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.

0 are shipped as single units, a grease pack is included (10 g per 1000 strokes). Order with the following part number when only the grease pack is needed.

0 are shipped as single units, a grease pack is included (10 g per 1000 strokes). Order with the following part number when only the grease pack is needed.

Center Q1 = 0.019 + 0.040 + 0.019 + 0.040 = 0.118 L(ANR) End Center End Center Air consumed in the tubing is calculated using formula (2), as shown below. 0.5 0.1 Q2 = 12.6 x 1000 x x 10-6 = 0.063 L(ANR) An entire stroke includes two rotations from end to center where the air is consumed. Thus, the total air consumption Q of the rotary table and tubing is obtained as shown below.

Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series

The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

The maximum detectable piston speed is: Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Time load applied (ms) V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

A retaining mechanism prevents the cushion needle from slipping out; however, it may spring out during operation if it is rotated beyond the ranges shown above. 15.00 10.00 32 5.00 25 20 0.00 10 100 1000 Maximum speed (mm/s) 19 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SLOVENIA SMC Industrijska Avtomatika d.o.o. SPAIN/PORTUGAL SMC Espaa, S.A.

14 10,11 12 20 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 12 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-15 3 Series ASD Dimensions: Metric Size ASD330F/430F ASD530F/630F ASD230F Applicable tubing O.D. d Applicable tubing O.D. d L2 L3 M L2 L3 M D2 D2 L1 L1

14 Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 20 Flow rate (l/min (ANR)) 10 11,12,13 12 10,11 08,09 1000 10 15 8 500 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-10-2 3 Series ASP Speed Controller

Note 3) Not used for 10 and 12. 15-16-9 10 Series ASR/ASQ Flow Characteristics Pressure Valve: Series ASR (Inlet pressure: 0.5 MPa) ASR430F ASR530F ASR630F 20 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area mm2 Effective area mm2 Effective area mm2 400 6 12 1000 15 300 4 8 500 10 200 500 4 2 5 100 10 5 0 10 5 0 10 5 0 Number of needle rotations Number of needle

14 Effective area (mm2) Effective area (mm2) 20 12 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-85 12 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F02 Component Parts No.

Effective area (mm2) Effective area (mm2) 14 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 20 12 12 10,11 10, 11, 12 08, 09 1000 10 15 8 500 06, 07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-53 12 Series ASD-FG Construction ASD230FG ASD330FG/430FG ASD530FG/630FG ASD530FG-02 @1 !

Effective area (mm2) Effective area (mm2) 14 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 20 12 12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-101 11 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F-02 !

Graph (3) 20 x 9.8 x (0.07 + 0.05) x 10/1000 = 0.24 20 x 9.8 x (m1 + m2) x H/1000 0.24 Nm < Effective torque OK < Effective torque (Nm) Find the moment of inertia, "IR" for the load + attachments (2 pcs.) 7 IR = K x (a2 + b2 + 12h2) x (m1 + m2)/(12 x 106) IR = 2 x (202 + 302 + 12 x 102) x (0.07 + 0.05)/(12 x 106) = 0.05 kgm2 (K = 2: Safety factor) Kinetic energy 8 Confirm that the kinetic

Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model 1000 (35) 200 (7) 500 (17.5) Max. flow capacity l/min (ANR)(SCFM) 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 (2.54) 0.43 (0.95) 0.68 (1.50) Weight kg (lb) Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less (14.5 psi