capacity (cm3) 55 135 7 25 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (With no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Option Standard Weight (kg) 0.47 0.24 1.13 0.07 0.20 0.52 1.06 Note 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C
of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C. * This is the calculated value by changing the fluid temperature only.
LLB Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) The accessories should be mounted by user.
Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) The accessories should be mounted by user.
JIS Symbol Proportional Solenoid Specifications Applicable power amplifier VEA250, VEA251 Max. current 1 A Coil resistance 13 (20C) VER2000 VER4000 Rated power consumption 13 W (20C, with maximum current) Class H or equivalent (180C) Coil insulation type 140C (With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Model VER2000 VER4000 Mounting screw
Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.
size) ASV 4 6 6 10 8 4 Flow rate [L/min (ANR)] It may damage the body A or fittings. 100 130 230 290 660 920 AK Controlled flow Body A Free flow Sonic conductance [dm3/(sbar)] 0.28 0.36 0.64 0.8 1.8 2.6 VCHC Controlled flow Free flow 0.2 0.25 0.2 0.25 0.2 0.25 0.2 0.25 Caution Release from One-touch fitting Critical pressure ratio ASR ASQ Note) Flow rate values are measured at 0.5 MPa and 20C
10 12 4 JIS Symbol Tubing O.D. 1 8" 3 16" 1 4" 1 4" 5 16" 5 16" , 3 8" , 5 32" 3 16" 1 4" 5 16" 3 8" 3 8" " 1 2 Inch size 5 32" Flow rate (/min (ANR)) 260 390 660 790 920 1580 180 230 460 1710 Flow Direction Symbols on Body Controlled flow (Free flow) Meter-out type Meter-in type Effective area (mm2) 4 6 10 12 14 24 2.7 3.7 7 26 Symbol Note 1) Flow rate values are measured at 0.5 MPa and 20C
Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
1800 IR Bowl capacity (cm 3) 440 Recommended lubricant Turbine oil Class 1(With no additives), ISO VG32 VEX Ambient and fluid temperature 5 to 60C (No freezing) Bowl material Polycarbonate AMR Weight (kg) 1.62 1.67 Bowl guard Accessory (Standard) ITV Note) Conditions: Inlet pressure = 0.5 MPa, Number of drop = 5 drops/min, Turbine oil Class 1 (with no additives) ISO VG32, Temperature = 20C
Inch size 1/4" 5/32" 3/8" 5/16" 1/4" 3/8" 1/2" Symbol 290 0.81 920 2.6 230 0.64 660 1.8 130 0.36 20 0.06 390 1.1 920 2.6 1390 3.9 Flow rate (L/min (ANR)) Sonic conductance dm3/(sbar) Controlled flow Free flow 0.2 0.25 Controlled flow Free flow Critical pressure ratio Note) Flow rate values are measured at 0.5 MPa and 20C.
3,600 55 0.34 AS420-03 5,000 3/8 77 4,800 74 0.33 63, 80, 100, 125 AS420-04 6,600 1/2 100 6,700 102 0.32 AS500-06 10,100 3/4 154 8,100 123 140, 160, 180, 200 0.36 AS600-10 15,100 1 230 16,900 258 160, 180, 200, 250 0.7 AS800-12 1 4 35,400 1 540 38,500 586 1.4 AS900-14 1 2 52,000 1 792 47,500 724 300 3.3 AS900-20 57,800 2 880 60,800 926 3.3 Note) Flow rate values are measured at 0.5 MPa and 20C
JIS Symbol Proportional Solenoid Specifications 1 A VEA25 Applicable power amplifier Max. current 13 (Ambient temperature 20C) Coil resistance 4(A) 4(A) 5(R1) 1(P) 3(R2) 5(R1) 1(P) 3(R2) 13 W (Ambient temperature 20C, with maximum current) Rated power consumption 2 (B) 2 (B) Coil insulation type Class H or equivalent (180C) Max. temperature rise 140C (Ambient temperature 50C, with maximum
fluid temperature: CH1: 20C/CH2: 25C at the device outlet. *6 Fluid flow rate to maintain the cooling capacity.
At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 5%.
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" Flow rate l/min (ANR) 1000 680 440 480 420 210 150 INOUT Effective area mm 15.2 10.4 6.7 7.3 6.4 3.2 2.3 Note 1) Flow rate values are at a pressure of 0.5MPa and temperature of 20C.
12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C
1800 IR Bowl capacity (cm 3) 440 Recommended lubricant Turbine oil Class 1(With no additives), ISO VG32 VEX Ambient and fluid temperature 5 to 60C (No freezing) Bowl material Polycarbonate AMR Weight (kg) 1.62 1.67 Bowl guard Accessory (Standard) ITV Note) Conditions: Inlet pressure = 0.5 MPa, Number of drop = 5 drops/min, Turbine oil Class 1 (with no additives) ISO VG32, Temperature = 20C
How to Calculate Minimum Bending Radius Burst Pressure Characteristics Curve and Operating Pressure 4.0 2R 3.0 Fixed end Pressure (MPa) Burst pressure 2.0 1.0 Maximum operating pressure Bend the tube into U-form at the temperature of 20C. Fix one end and close loop gradually.
Capacity between levels 350) Turbine oil Class 1(With no additives), ISO VG32 5 to 60C (No freezing) Polycarbonate Bowl capacity (cm 3) Recommended lubricant Ambient and fluid temperature Bowl material 1.56 1.78 Weight (kg) Bowl guard Accessory (Standard) Note) Conditions: Inlet pressure = 0.5 MPa, Number of drop = 5 drops/min, Turbine oil Class 1 (with no additives) ISO VG32, Temperature = 20C