Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb
ms) (2)Weight (g) 1 4/2 (P A/B)4/2 5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
(ms) (2)Weight (g) 1 4/2 (P A/B)4/2 5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
Note 2) Specify the wiring so that the maximum number of solenoids is not exceeded. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P double solenoids.) Note 3) When specifying the negative common specifications of the L kit, suffix N to the kit symbol. 578
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Note 2) (Nominal size) is not needed as the part number starting with the AL-H is a dedicated number. Note 3) The material of seals (AL-128H-V to AL-137H-V) is EPDM-70. 503 A
Outside Diameter Actual Size 1/8 27 NPT 1/4 18 NPT 3/8 18 NPT 1/2 14 NPT 3/4 14 NPT 1/16 27 NPT 0.313 Diameter 0.453 Diameter 0.540 Diameter 0.666 Diameter 0.840 Diameter 1.050 Diameter 2
VEA 5 (R1) 4 (A) 1 (P) 2 (B) VY2 OFF state VBA VBAT F1 < F2 condition: See figure q. 2 (B) 3 (R2) AP100 4 (A) ON state Immediately after turning on F1 > F2: See figure e. Thereafter F1 = F2: See figure w. 4 (A) 1 (P) 2 (B) 3 (R2) Inw, port 3(R) is half open. 705
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: LT (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C, Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: LT (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2 (PFA, M6), Option: 2 (Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2 (PFA, M6), Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)