SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-L-02L-WK"

= 100 (1.0 kg) Wc: Rod L = 50 (0.5 kg) Wd: Workpiece (3.0 kg) [2] Load Blocking Mass and center of gravity of the load Y Center of gravity Load no.

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 33 25 10 10.5 10.5 12 8.5 13.75 4 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 30 10 18 11.6 19.5 23 20 29 53.2 9.1 14.1 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 34 14 22 15.6 23.1 27

Tube swaged J O int rTSJ) for use with Swagelok<l type fittings 1 Digital Pressure Switch Series ZSE6/ISE6 How to Order Vacuum pressure switch Positive pressure switch ZSE68 82 27 IL ISE68 Switch type L,.,., '",..

IFW5 10 03 N 1 1 PSE Z I SE3 Diaphragm style flow switch PS Light 0 None Z I SE1 2 1 With neon light (110 VAC, Red) 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting possible (1 l/min) 10 1 to 10 l/min 4 With neon light (220 VAC, Green) 20 10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from

(ANR)) 4B 1B B AMF250 AMF650 AMF1000 1 4 0.1 MPa 0.1 MPa 0.1 MPa Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) 2B AMF350 AMF800/801 B 3 8 0.1 MPa 0.1 MPa Pressure drop (MPa) Pressure drop (MPa) Max. flow line Air flow rate (m3/min (ANR)) Air flow rate (l /min

Auto switch CUJ cylinder Cylinder B Cylinder A Auto switch Magnetic substance Non-magnetic spacer of 2.5 mm or more Without Shielding Plate d Bore (mm) 10 L 6 8 L d 19 6 19 6 19.5 6 The space can be reduced by attaching shielding plates (steel plates 0.2 to 0.3 mm thick) to the sides of the cylinders facing each other.

Approx. 1 second M3 x 8 L Water proof seal (accesorys) Measurement mode 4 L/min 40 L/min 100 L/min 16 L/min 250 L/min Panel Be sure to select the correct sensor to be connected. Caution *: The panel mount adapter can be rotated through 90 degrees for mounting. *: The panel mount adapter should be fixed firmly with screws. Otherwise, fluids such as water may enter.

min 2.5 to 100 L/min 5 to 200 L/min Operating Fluid temperature *2 0 to 85oC (No condensation or freezing) Repeatability Analogue output: +/-1.5F.S.

C aution S tart & S top C onnect air piping to the port P1 P2 , and transported fluid piping to the suction port F L UID IN and the discharge port F L UID OUT respectively. S et pilot air pressure in the range of 0 .2 MPa and 0 .5 MPa by using regulator. K eep ball valve open on the discharge side.

Piping F or piping to the port F L UID IN or F L UID OUT , tighten it securely w ith tooling such as spanner. Use flexible tube, filtration of 0 .2 mm at least on IN port. L ife S pan and Replacement Diaphragm should be changed before the life indicated. If diaphragm should be damaged, transported fluid w ill leak into the pump and damage inner components.

Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 12 L/min. Since this is equivalent to 68% of the discharge rate for fresh water, 12 L/min 0.68 =17.6 L/min, indicating that a discharge rate of 17.6 L/min is required for fresh water. 3.

D-MS-A Mounting screw (M2.5 x 4 L, Steel (Black zinc chromate)) 1 pc. D-MS-AP Mounting screws (M2.5 x 4 L, Steel (Black zinc chromate)) 10 pcs. D-MS-B Mounting screw (M2.5 x 4 L, SUS) 1 pc. D-MS-BP Mounting screws (M2.5 x 4 L, SUS) 10 pcs. ISA-2-1 DIN rail (Width 35 mm x Length 105 mm) 1 pc. ISA-2-2 DIN rail (Width 35 mm x Length 140 mm) 1 pc.

(This detection is "H/L reference " only. "Pulse Input Method" cannot be detected.) When the first SVON input is ON during the pulse inputting, the H/L reference cannot be detected.

Checks and Maintenance 6.1 Specifications erature bowlItem Specification Outlet air pressure dew point 10 o C IDH410 IDH4 20 IDH A 423 Rated performance IDH6 10 ) release bushOutlet air temp IDH 6 20 IDHA 6 23 (2) Mounting of the bowl assembly Note 1 ) 2) ir flow capacity 400 L/min ANR Operating range Fluid Compressed air Amount of air processed 100 to 5 00L/min ( 600 L/min ANR Inlet

The allowable voltage fluctuation is -15% to +5% of the rated voltage for the 115 VAC or 230 VAC. *2 Type Y is a DIN terminal conforming to EN-175301-803C former DIN43650C. *3 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. -20- Manual operation AV L 2 0 A AV L 2 0 1 G A with solenoid valve Applicable size Symbol Description AVL AVL AVL AVL 2000 3000

AF-OMX0053-B PRODUCT NAME Mist Separator MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 14 Position for application of grease Table 9 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 28 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.14, ) Pay attention to the mounting direction of the seal.

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 12 Position for application of grease Table 9 Amount of grease A units: g Stroke 32 40 50 63 80 100 125 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 15 to 17 50st added 1 1 1 1.5 2 3 3 28 3-2-4.

Model D L M M M AKH03-00 AKH07-00 AKH09-00 AKH11-00 AKH13-00 3 6 10 17 24 2.8 6.5 14 24 34 5/32 1/4 5/16 3/8 1/2 9.3 12 15.2 18.5 21.7 33.5 39 53.3 63.6 70.2 12.7 13.6 18.5 21 22 L Male Connector Type: AKH Millimeter Size Connection thread R Applicable tube O.D.