278 7 0.073 0.293 1.17 4.68 18.7 42.2 75.0 117 168 230 300 9 0.083 0.331 1.32 5.30 21.2 47.7 84.7 132 191 260 339 12 0.095 0.379 1.52 6.07 24.3 54.6 97.0 152 218 297 388 15 0.105 0.420 1.68 6.72 26.9 60.5 108 168 242 329 430 20 0.123 0.491 1.96 7.86 31.4 70.7 126 196 283 385 503 25 0.140 0.562 2.25 8.98 35.9 80.9 144 225 323 440 575 30 0.158 0.633 2.53 10.1 40.5 91.1 162 253 365 496 648 35
Refer to page 3-13-4.) 20 or less 35 or less 10 3 2 position single Operating pressure range (MPa) 2 position double 3 position Ambient and fluid temperature (C) Response time (ms) (1) (at the pressure of 0.5 MPa) 2 position single, double 3 position 2 position single, double 3 position Max. operating frequency (Hz) Effective area Refer to the table below.
Refer to page 3-13-4.) 20 or less 35 or less 10 3 2 position single Operating pressure range (MPa) 2 position double 3 position Ambient and fluid temperature (C) Response time (ms) (1) (at the pressure of 0.5 MPa) 2 position single, double 3 position 2 position single, double 3 position Max. operating frequency (Hz) Effective area Refer to the table below.
(mm) Connection thread R 10 D1 Note) D2 Model L1 L2 FR soft nylon FR double layer KRK06-02S KRK06-01S 1 8 12 10 33 13 21 35 25 26 36 33 MS 20.5 24.5 26.5 22 26 28 24 27 29 33 27.5 29.5 33.5 10 18 36.5 35 1 4 19 3.4 14 17 12 14 17 6 12.8 6.9 KRK06-03S 37 19.7 3 8 1 8 Applicable tubing T KRK08-01S KRK08-02S KRK08-03S KRK10-01S KRK10-02S KRK10-03S 1 4 3 8 1 8 1 4 3 8 39 41 42 43.5 45 15.2 12
(For details, refer to "Specific Product Precautions 1" on page 849) +50 0 3000 VEF VEP (30.9) 35 15 Body VER 4 8.7 9.9 VEA Cable connector (4 cores) Straight type (Option) 7 14 VY1 Cable connector (4 cores) Right angle type (Option) VBA VBAT AP100 (21.8) Minimum bending radius 80 (24) Body SMC (24) SMC M8 10 4 200050 (45) (15) 811 Series ITV0 Dimensions Single unit for manifold 50 ERR PWR
bracket mounting screws (M5 x 35). 2 Accuracy 3% (Full span) 554 Precision Regulator Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 i i q o q o i !
35 P 47 47 AL30 AL40 AL40-06 AL50 AL60 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 324 333 333 332 335 38 40 38 41 45 53 70 75 90 95 14-2-65
+ 30 (n 2) 10 35 100 Note) For cylinders with two D-A93/M9/M9W auto switches.
Status LEDs 24 VDC 10% Power supply voltage Current consumption 35 mA or less Enclosure IP40 0 to 50C (with no freezing and condensation) Operating fluid temperature Operating: 0 to 50C Stored: 10 to 60C (with no freezing and condensation) Operating temperature range Operating humidity range Operating, Stored: 35 to 85%R.H.
(mm) Bore size (mm) A B C D E FA FB G H I J K L M N O1 O P Q RA RB RR RH T W Z 32 100.5 82.5 14 22.4 45 33 12.5 9 M8 x 1.25 60 4.5 17 18 34 5.5 M6 x 1.0 9 Rc 1/8 24.5 14 10 5.5 7 4.5 49.5 14 40 110 92 28 14 M10 x 1.5 26 57 16 52 35 9 69 5 24 18 40 5.5 M6 x 1.0 9 Rc 1/8 14 10 5.5 7 4.5 14 50 118.5 96.5 M8 x 1.25 35 14 M10 x 1.5 30 71 16 64 37 12 86 7 30 22 50 6.6 11 Rc 1/4 17 14 3 8 5.5 19
Pressure characteristics 5%F.S. max. (0.35 MPa reference) Temperature characteristics 2%F.S. max. (15 to 35 C) 5%F.S. max. (0 to 15 C, 35 to 50 C) Rated pressure range -70 to 750 kPa Proof pressure 1 MPa Switch output NPN or PNP open collector output Max. load current 80 mA Max. load voltage 28 VDC (NPN output) Internal voltage drop NPN output: 1 V (at 80 mA), PNP output: 1.5 V or less (at
40 45 0 5 10 15 20 25 30 35 40 45 [50 Hz] Circulating fluid temperature [C] [60 Hz] Circulating fluid temperature [C] 012 018 024 A W HRS -20 (Single-phase 200 to 230 VAC) 1000 1000 Ambient 40C Ambient 32C Ambient 25C Ambient 40C 800 800 600 600 Ambient 32C 400 400 Ambient 5C Ambient 20C Ambient 25C Ambient 5C Ambient 20C 200 200 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 [50
auto switch Solid state auto switch (2-wire, 3-wire) 2-color indication solid state auto switch (2-wire, 3-wire) MXS MXQ +1 0 mm Stroke length tolerance Extension end 5 mm/Retraction end 5 mm Stroke adjustment range MXF MXW IN MXJ OUT Theoretical Output (N) MXP Operating pressure (MPa) Bore size (mm) Rod size (mm) Piston area (mm2) Operating direction 0.7 0.6 0.5 0.4 0.3 0.2 MXY OUT 50 35
25 (12) (12) 35 20.5 15.5 18.5 29 24 50 (12) (12) 28.5 16.5 12.5 14.5 23 19 75 3 (12) 24 14 10.5 12.5 10.5 20 16 100 (12) 21.5 12 9 11 9 17.5 14 125 19 11 8 9.5 8.5 11 15.5 12.5 150 The data in ( ) are limited by max. stroke length.
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.
Controller Operation Examples. 31 6.1 Basic Settings, I/O Configuration . 31 6.2 Step Data Configuration . 31 6.3 Operation Data Acquisition . 32 6.4 Operation Instruction Method . 32 6.5 Program Examples . 33 (1) Basic Settings . 33 (2) Communication check . 33 (3) Step Data Configuration Examples . 33 (4) Return to Origin . 34 2 (5) Positioning Operation (Step Data Operation) Example . 35
Mounting with panel mount adapter Panel mount adapter (Model: ZS-35-C/ZS-35-D) Panel mount adapter + Front protective cover (Model: ZS-35-F/ZS-35-G) Troubleshooting Warning Error indication function This function is to display error location and content when a problem or an error occurs. Panel Do not disassemble, modify (including changing the printed circuit board) or repair.
(Tensile force 35 N or less) Hold the body when handling to avoid the damage of the Pressure switch which lead to cause the failure and malfunction. For piping of the Pressure switch, hold the piping with a spanner on the metal part of the piping (Piping attachment). Holding other part with spanner leads to damage the Pressure switch.
Model: ZS-35-C Bottom piping ... Model: ZS-35-B Panel mount adapter + Front protective cover Rear piping ... Model: ZS-35-F Bottom piping ... Model: ZS-35-E
General specifications Item Specification Enclosure IP20 Ambient operating temperature -10 to +50oC Ambient storage temperature -20 to +60oC Ambient humidity 35 to 85% RH (no condensation) Withstand voltage 500 VAC 1.0 min.