Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Without
.· Operating temperature: 200°C (varies depending on the conditions).· Maximum operating pressure 2.3 MPa or less (at 20°C) (varies by size).· Complies with the FDA (Food and Drug Administration) §177-1550 dissolution test.
.· Maximum operating pressure (at 20°C): 1.0 MPa.· Operating temperature: 0 to 200°C.· The reducer method allows tubing size changes without replacing the body.
.· Maximum operating pressure (at 20°C): 1.0 MPa.· Operating temperature: 0 to 200°C.· The reducer method allows tubing size changes without replacing the body.
Features · With a high temperature stability of ±0.1°C due to a precise temperature control method that uses an expansion valve and a temperature sensor.· With a compact tank.· Power supply: Single-phase 200 to 230 V AC.· Set temperature range: 5 to 40°C.· HRS-0□□-A: Air-cooled refrigeration type.· HRS-0□□-W: Water-cooled refrigeration type.
to 62 or less; Ambient & fluid temperature: metal seal -10 to 50°C;rubber seal -5 to 50°C; Optional IP65 enclosure
Cooling capacity: 600 W, 1200 W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 200 ~ 220 VAC, 50/60Hz ; Circulating fluid: Clear water or fluorinated fluid ; Standards: CE
to 62 or less; Ambient & fluid temperature: metal seal -10 to 50°C; rubber seal -5 to 50°C; Optional IP65 enclosure
to 75 or less; Ambient & fluid temperature: metal seal -10 to 50°C;rubber seal -5 to 50°C
to 75 or less; Ambient & fluid temperature: metal seal -10 to 50°C;rubber seal -5 to 50°C
.: Ø 4 to Ø 12 mm; Operating temperature: -20 to 200 °C for air and 0 to 100 °C for water.
The TIL series is also compatible with maximum fluid temperatures of up to 200°C. Applicable tubing O.D.: 1/8" to 1"; Max. operating temperature: 260 °C; Colour: translucent.
Inverter compressor, fan, and pump for efficient power consumption ; Cooling capacity: 9.5kW (Air), 11kW (Water) ; Temperature range setting: 5 to 40° C ; Temperature stability: ±0.1° C ; Standards: CE (400V only), RoHS ; Circulating fluid: Tap water, deionized water, or 15% ethylene glycol solution
Cooling capacities: 9kw (air cooled), 10.5kW (water cooled); Temperature range setting: 5 to 35°C; Temperature stability: ±0.5°C; Power supply requirements: 3-phase 200VAC; 50Hz; 200~230VAC 60Hz; 380~415VAC 50/60Hz; 460~480VAC 60Hz; Refrigerant: R410A HFC; Circulating fluid: tap or deionized water or 15% ethylene glycol solution
Cooling capacity: 600 W, 1200 W ; Temperature range setting: 10 to 60°C ; Temperature stability: ±0.03°C or better depending on load stability ; Power supply requirement: single phase 200 ~ 220 VAC, 50/60Hz ; Circulating fluid: Clear water or fluorinated fluid ; Standards: CE
Inverter compressor, fan, and pump for efficient power consumption ; Cooling capacity: 9.5kW (Air), 11kW (Water) ; Temperature range setting: 5 to 40° C ; Temperature stability: ±0.1° C ; Standards: CE (400V only), RoHS ; Circulating fluid: Tap water, deionized water, or 15% ethylene glycol solution