Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 420, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: B54, Lead Wire Length(m): 3,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Speed, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.025~1.0, Specification: Built-in magnet, Port thread type
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B54, Lead Wire Length
Magnet: Built-in, Mounting: Front Flange, Cushion: Non-lube Air Cushion, Bore Size: 40mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B54, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B54, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 440, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B54, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B54, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B54, Lead Wire Length
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Bearing Style: L (Ball Bush Bearing), Mounting: B (Basic), Bore Size: 40mm, Thread: Rc, Stroke: 200mm, Lock Position: H (Rear Locking), Release of Manual: L (Locking), Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bearing Style: L (Ball Bush Bearing), Mounting: B (Basic), Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Lock Position: H (Rear Locking), Release of Manual: L (Locking), Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bearing Style: L (Ball Bush Bearing), Mounting: B (Basic), Bore Size: 32mm, Thread: Rc, Stroke: 250mm, Lock Position: H (Rear Locking), Release of Manual: L (Locking), Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bearing Style: L (Ball Bush Bearing), Mounting: B (Basic), Bore Size: 40mm, Thread: Rc, Stroke: 250mm, Lock Position: H (Rear Locking), Release of Manual: N (Non-locking Type), Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)