Part number Description Remarks ZS-37-A Lead wire with connector (Straight) Length: 3 m ZS-37-B Lead wire with connector (Right angle) Length: 3 m ZS-29-T Bracket (PF2W704/720) Mounting screw (3 x 12 Self tapping screw) 4 pcs. ZS-29-V Bracket (PF2W740/7T) Mounting screw (3 x 12 Self tapping screw) 4 pcs.

The programmed Key(s) will give an output signal for as long as the key is depressed.

A specied earth leakage breaker is installed for option B [With earth leakage breaker], B1 [With earth leakage breaker with handle] and S [Conforming to CE/UL standards]. Note 9) If the product is used at altitude of 1000 m or higher, refer to Operating Environment/Storage Environment (page 186) Item 13 * For altitude of 1000 m or higher.

*Vertical Horizontal Mounting position Ground ball screw (0.02mm) Rolled ball screw (0.05mm) Slide screw (0.1mm) Positioning repeatability 100 to1500mm 100 to 600mm Stroke to 60kg to 20kg Work load to 1000mm/s to 600mm/s Speed Tentative determination of actuator model Review of moment Confirmation of allowable moment NG OK Determination of actuator model When mounted in a vertical position

*Lead wire length symbols: 20in (0.5 m) . Nil (Example) M9N 118in (3 m) . L M9NL 197in (5 m) .

OUT2 Load White Load (41.5) LED Red Blue PFW7--67 (-M) Connector pin numbers 4 3 42 4 2 1 2-3.4 43 Pin description DC (+) OUT2 DC () OUT1 Pin no. 1 2 3 4 Flow direction Dimension L 100 106 Model PFW704 PFW720 PFW740 1.6 23 64 120 FLOW SWITCH U P S E T 34 60 50 OUT1 OUT2 DOWN FOR WATER 2-Port size 34 4-4.5 40 50 (41.5) 73 Flow direction 24 For Water Digital Flow Switch Series PFW Dimensions

Safety Instructions Be sure to read Precautions for Handling Pneumatic Devices (M-03-E3A) before using.

(EX245-EA2-1) No. 1 SI ON/OFF 2 IO-Link IO-Link 3 4 5 SI 6 . 1-1 12 No.EX-OMW0014CN-A 2. . 2-1 EX245 DC24 V 1 msec IP65(,) (IEC 60529 ) CE/UKCA UL(CSA) RoHS EN505812012 AC500 V1 FE 10 M -FE DC500 V -1050 -2060 35%85%RH 1057 Hz0.75 mm p-p 57150 Hz49 m/s 2 XYZ 2 (IEC60068-2-6) 147 m/s 2 XYZ 3 () (IEC60068-2-27) 13 No.EX-OMW0014CN-A 3. 3.1. 6 2M5( = 1.5 Nm

Please refer to "Fig.1 Allowable lateral load applied to rod end ". ( Page 10) Table 2 Allowable kinetic energy CG5 N A Formula E= ( m/ 2 )v2 Bore size( mm ) E max ( J ) E max ( J ) 20 0.28 0.42 E Kinetic energy ( J ) m : Load mass ( Kg ) v Max. piston speed ( m/s ) 25 0.41 0.65 32 0.66 0.91 40 1.2 1.8 50 2.0 3.4 EE max ( J ) Should be satisfied. 63 3.4 4.9 80 5.9 11.8 100 9.9 16.7 Warning

Zoom Choose from 200, 150, 100, 75, 50, 25, or 10% zoom factor 5.4 Insert Icons into Vacant Terminals Input S and Output S icons will be inserted into any vacant Input or Output Terminals, respectively. Insert New Object Insert a Display, OLE, or le into the System Sketch Window. Links... Edit links between the SMC VLS le and other documents.

s) Conditions: Piping length/30 m Steel tube, full pressure/0.5 MPa 17-4-21 2 Series VNC How to Order Thread type Seal material Bracket (Valve size: 1/2/3/4) Nil B Nil F N T A B Rc G NPT NPTF None With bracket (VN-16) is valve size NBR seals FKM seals Note 1) Valve size 1 comes with VN1A16 (with thread).

Only 1.5 m cables usable with open collector. 3 For the LECPMJ, only Nil, S and T are selectable since I/O cable is not included.

Symbol Stroke O.D. thread size 0604 0806 1007 1412 2015 2725 6 mm 4 mm 2 pcs. 1 pc. 8 mm 6 mm 3 pcs. 1 pc. 10 mm 7 mm 1 pc. 14 mm 12 mm Note) RJ0604: "Nil" or "N" only 20 mm 15 mm 27 mm 25 mm With cap Nil U Basic type Collision speed range With urethane cap H L 0.05 to 2 m/s 0.05 to 1 m/s Specifications RJ1007 RJ0604 RJ0806 RJ1412 RJ2015 RJ2725 Basic type RJ0806U RJ1007U RJ1412U RJ2015U

When connecting the drain piping, use the piping with I.D of 8 mm or more and the length should be within 5 m. Riser pipework should be avoided. (Back pressure is applied.) Drain cock is loosened. Tighten the drain cock to "S" side of the manual knob. Drain does not enter. Element is clogged. Remove the clogging by cleaning the element and blowing it with air. Or, replace the element.

Applicable standards Cord length Connector type JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 0.5m 1.0m 3.0m M83 pin M84 pin M124 pin S M L A B D Impact resistance 300m/s {30, 6G} Enclosure IP-67 (standard IEC529) Note) Series D-P5DW is available with type D only. Withstand voltage Note) L is available for series D-P5DW only.

Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.

. *2 With ejector 63, 80 Application Examples Robot handling Palletizing Automobile Case packer 254 Vacuum Pad with Ejector ZHP Series 63, 80 RoHS ZK2 How to Order ZQ ZHP 80 BM N B 00 Without ejector ZR ZB ZHP 80 BM N B 10 C6 S With ejector ZA Pad diameter Exhaust release ZX 63 63 80 80 S Silencer exhaust ZM Supply (P) port Pad form Symbol Type Port size C4 Metric 4 One-touch fitting C6 6

SRF 1 07 11 0 S S 1 With nut Body size 1 3 5 Fitting type Pilot port thread type Made to Order (Refer to page 887 for details.)

Two speed control ranges, M (1~50 mm/s) and C (50~150 mm/s); Push-lock and push-lock/indicator models available; Elbow/universal and in-line types; Imperial and metric variations

Two speed control ranges, M (1~50 mm/s) and C (50~150 mm/s); Push-lock and push-lock/indicator models available; Elbow/universal and in-line types; Imperial and metric variations