How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
To reassemble, push button firmly into spring clip. 2 Series NVM MECHANICAL VALVES HOWTO ORDER DIMENSIONS NVM 100 HOW TO ORDER NVM 120 N01 065 -rr vatve series T = 2-way;2porls = 3-way;2ports 120 130 I lRoller Material (06 & 07 Only) | -: Nylon(Standard) I S : Steel I lActuator 00 = Valve Body Only 05 = Plunger 06 : Roller plunger Inline 07 = Roller Plunger, Set 90" 08 : Toggle 30 = Push
AC4000 06 1 8 AC50 AC5000 1 8 AC55 AC5500 1 8 X Better water removal and increased filter life !
(mm) Note) Weight (g) L2 A M L1 D1 D2 Urethane KJL23-04 KJL23-06 KJL04-06 1.1 1.2 1.4 Note) D1: Max. diameter 4 6 6 24.3 25.3 15.8 16 25.7 3.2 2.2 2.6 12.7 8.4 6 14.5 4 16.9 12.7 3.5 3.5 6 15.6 9.3 Applicable tubing Applicable fitting Extended Male Elbow: KJW H (width across flats) Applicable tubing O.D.
(Including bracket, screw, set screw) Cylinder series Applicable bore size (mm) 32 40 50 63 80 100 125 BT-08 140 160 180 200 MDB MDBB, MDNB CDA2, CDBA2 CDA2Q CDA2H CDA2Y, CDLA CDNA, CE2 CDV3, CDVS1 CDL1 CDS1, CDLS CDS2 CDNS BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 BT-04 BT-04 BT-06 BT-08 BT-08 BT-20 BT-18A BT-12 BT-12 BT-16 [Mounting screws set made of stainless steel] The following
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
BA-08 BA-10 BA -01 BA -02 BA -32 BM2 -020 BM2 -025 BM2 -032 BM2 -040 BA -04 BA -05 BA -06 BA -08 BA -10 BMA2-050 BMA2-063 BMA2 -020 BMA2 -025 BMA2 -032 BMA2 -040 BA01 BA02 BA32 BMA2-050 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available.
How to Order AD402 03 06 AD600 Metal bowl 2 Nil Option Thread type Thread type Nil N F Nil N F Rc NPT G Rc NPT G Port size Port size OUT IN Symbol OUT IN Symbol 06 3 4 3 4 1 1 3 8 3 8 02 1 4 3 8 10 04 03 1 2 3 8 73 Related Products: Auto Drain Valve Series AD402/600 Construction/Dimensions AD402 AD600 !
Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.
-D 157.6 155.9 151.5 156 171.5 176 -28- Revision history Size 40-06 added.
To reassemble, push button firmly into spring clip. 2 Series NVM MECHANICAL VALVES HOWTO ORDER DIMENSIONS NVM 100 HOW TO ORDER NVM 120 N01 065 -rr vatve series T = 2-way;2porls = 3-way;2ports 120 130 I lRoller Material (06 & 07 Only) | -: Nylon(Standard) I S : Steel I lActuator 00 = Valve Body Only 05 = Plunger 06 : Roller plunger Inline 07 = Roller Plunger, Set 90" 08 : Toggle 30 = Push
Olill3.0iltx5(fl{Sl 5.0 18.8{ 7 { t + 010/.0M 7 q l + 010/ m l . +.0050 /..010 r.50 .630 +.AN/-.0n0 3.881.50 1.50 L40 |.06 il/A .90 0Eltll3.()ilx6.5(.lt(S) 6.5 22.59 7 5 1 *.oi 7. ooo .t 5l + 0t0/.1 -h9^q {0 L + 00150 / 010 1.50 3.56 .630 +.020/-.000 3.88 1.501.501.40r.06 t.ii N/A .90 33.6 lbs.
How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.
Recommended piping port size Emitter cartridge Bar length mm One-touch Applicable tube type fitting symbol O.D. mm Single end piping Double ends piping 06 6 340 to 640 340 to 1300 08 8 340 to 1300 340 to 2500 10 10 340 to 2500 340 to 2500 06 6 340 to 1300 340 to 2500 08 8 340 to 2500 340 to 2500 10 10 340 to 2500 340 to 2500 06 6 340 to 2500 340 to 2500 08 8 340 to 2500 340 to 2500 10 10
AF-OMQ0004-C PRODUCT NAME AIR FILTER MODEL / Series / Product Number AF10-M5(C)(-2,6,R,Z)-A AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A AF50-(F,N)06(F,N)10(B)(-2,6,8,J,R,W,Z)-A AF60-(F,N)10(B)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2.
0 q 4 Series LVR Dimensions Integral ttings/LQ3 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Model A B C D E LVR20-Z07(06) 40 40 49.3 68 20.1 LVR40-Z11(10) 82.5 82.5 89 115 33 LVR40-Z13(12) 82.5 82.5 89 115 33 LVR50-Z19 100 100 117.5 135 45 Breathing port M5 x 0.8 IN Model F G H J LVR20-Z07(06) 8 27 56 88 LVR40-Z11(10) 14 64.5 100 150.5 LVR40-Z13(12) 14 64.5 100 159.5 LVR50-Z19
(Nominal size) Port size Hydraulic fluid Material 04 06 08 10 12 16 20 24 28 32 04 06 08 10 12 16 20 24 28 32 AL-128H AL-129H AL-131H AL-132H AL-134H AL-135H AL-136H AL-137H KA00813 (V120) AL-128H-V AL-129H-V AL-131H-V AL-132H-V AL-134H-V AL-135H-V AL-136H-V AL-137H-V KA00728 (V120) KA00815 (V85) KA00812 (V100) KA00813 (V120) KA00814 (V150) KA01800 (V175) KA00731 (V85) KA00727 (V100) KA00728
Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure
Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.