Configuration: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: R (External Pilot), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, 1: 1, Porting Specification: Side Ported, Port Size: 03 (3/8), Thread: T (NPTF)
Stations: 5 Stations, Port Size: 03 (Rc3/8), Thread Type: Rc, Kit Name: FD3 (D-sub Connector 25 Pin 5.0m)
Actuation Type: 3 (3 Position Closed Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8)
Function: 3 (3 Position Closed Center), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: N (NPT)
Stations: 5 Stations, Port Size: 03 (3/8), Thread: N (NPT), Kit Name: TD0
Function: 3 (3 Position Closed Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: B (Bottom), Port Size: 03 (Sub-plate 3/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Actuation Type: 3 (3 Position Closed Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: B (Locking Slotted Style), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 03 Station Manifold, Tie-Rod Base. 0.64 lb. VVM.
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: F (G)
Function: 4 (3 Position Exhaust Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping)
Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: R (Surge Suppressor Non-polar), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: T (NPTF)
Type of Actuation: 4 (3 Position Exhaust Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Stations: 5 Stations, Port Size: 03 (Rc3/8), Thread Type: Rc, Kit Type: 3 (5.0m Cable)
Stations: 5 Stations, Port Size: 03 (3/8), Thread: N (NPT), SI Unit: SNB (PROFIBUS DP - 16 Outputs - Connector M12), SI Unit COM: N (-COM)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Series: SV4000, Function: 1 (2 Position Single), Pilot: Internal Pilot, Voltage: 5 (24VDC), M12 Waterproof Connector: W1 (300), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Driver Operation Manual Button), Port Size: 03 (3/8)