Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Size: 30, Standard Dew Point: -20°C, Type: A, Thread: N (NPT), Port Size: 03 (3/8), Accessory: B (Bracket), Option: PR (Fitting for Purge Air Exhaust/Flow Right to Left)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 4 (220VAC 50/60HZ), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: YO [DIN Terminal w/o Connector (DIN 43650C)], Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: F (G)
Size: 50, Standard Dew Point: -20°C, Type: A, Thread: F (G(PF)), Port Size: 03 (3/8), Accessory: B (Bracket), Option: R (Flow Direction: Right->Left)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 5 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (3/8)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: 1RYZ (1 + R + Y + Z)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8), Thread: F (G), Control Unit: G (Filter Reg. w/Manual Drain,Blank Plates for Air Release Valve&Press. Switch)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Size: 30, Base Dew Point: L (-40°C), Type: A (Energy Saving Design), Equipment Connection: 4 (Modular Connection), Thread: N (NPT), Port Size: 03 (3/8), Draining: J (Drain Guide Port 1/4 w/o Valve)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WAO [M8 Connector w/o Connector (IEC60947-5-2)], Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 03 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: T (NPTF)
Size: 50, Base Dew Point: -20°C, Type: A (Energy Saving Design), Equipment Connection: 4 (Modular Connection), Thread: N (NPT), Port Size: 03 (3/8), Draining: C (N.C. Auto Drain), Option: R (Flow Direction: Right->Left)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)