Magnet: Built-in, Mounting: Basic, Cushion: Air Cushion, Bore Size: 1", Stroke: 16", Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Basic, Cushion: Rubber Bumper, Bore Size: 2 1/2", Stroke: 16", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 3/8", Suffix: Required Selection w/Speed Control
Magnet: Built-in, Mounting: Foot, Bore Size: 125mm, Port Thread: NPT, Stroke: 1600mm, Rod Boot: None, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: 5m, Number: -
Type: Standard Type, Bar Length: 1600mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: 3m, One-Touch Fitting: ø1/4", Bracket: Bracket, Sensor: -, Option: -
Type: Standard Type, Bar Length: 1600mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: 3m, One-Touch Fitting: ø3/8", Bracket: -, Sensor: -, Option: -
Type: Standard Type, Bar Length: 1600mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: 3m, One-Touch Fitting: ø1/4", Bracket: -, Sensor: -, Option: -
Type: Feedback Sensor Type, Bar Length: 1600mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: 3m, One-Touch Fitting: ø5/16", Bracket: Bracket, Sensor: -, Option: -
Magnet: Built-in Magnet, Mounting: Foot, Bore Size: 160mm, Thread: NPT, Stroke: 1600mm, Rod Boot: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel, w/Hand Chrome Plated Piston Rod
Style: Standard Type-Air Cushion, Bore Size: 32mm, Port Thread: Rc: ø25, ø40, ø50, ø63/M Thread: ø16, ø20, Stroke: 1600mm, Stroke Adjusting Unit: -, Auto Switch: -
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 3 1/4", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9NW, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9PWV, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: APC, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9PW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 3 1/4", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 3 1/4", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 3 1/4", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 16", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Custom-made Specifications: None