SMC Corporation of America
Elite Part Number Search
Search Results "MHQJ2-20C-M9PVL"

(mm) 4 6 8 10 12 3.18 4.76 6.35 9.53 12.7 2.5 4 5 6.5 8 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst Pressure Characteristics Curve Yellow (Y) Green (G) Clear (C) Orange (YR) Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Specifications Fluid Air, Water Max. operating pressure 0.8MPa at 20C Refer to pressure characteristics curve.

AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C

temperature Round lock nut With seal, Round lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 230 105 20 1700 920 460 Flow rate L/min (ANR) Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.7 0.32 2.8 1.4 0.06 5.2 Critical pressure ratio Controlled flow 0.25 0.2 0.3 0.2 0.25 0.25 Free flow 0.4 0.3 0.2 0.4 0.3 0.2 Note 1) Flow rate values are measured at 0.5 MPa and 20C

210 210 250 200 230 320 385 335 380 210 240 200 230 170 200 175 210 165 195 165 195 165 195 165 195 165 195 50Hz 60Hz 50Hz 60Hz AC 100V AC 200V Power consumption (W) Note2) 50/60Hz Refrigerant Air connection Weight R134a 28 Rc3/8 23 Rc1/2 27 Rc3/4 28 Rc3/4 27 23 Rc1/2 22 18 Rc3/8 17 16 (kg) White1 (Munsell 10Y8/0.5) Coating color Note1)The data for l/min (ANR) is under the conditions of 20C

Air consumption Note 3) 18 L/min (ANR) or less (SUP = 0.5 MPa) Note 1) Specification values are given at normal temperature (20C). Note 2) Characteristics relating to accuracy differ depending on combination with other constituent loop equipment, such as positioners and actuators. Note 3) Air consumption is due to exhaust from nozzle. And (ANR) indicates JIS B0120 standard air.

Metric size 4 4 6 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C.

ANR: 20C atmospheric pressure, relative humidity 65% 200 300 1,000 1 4 3 8 1 4 3 4 1 2 , , 0.12 AMC-EL2 BE20 0.2 AMC-EL3 BE30 0.5 AMC-EL5 BE50 VEX How to Order AN 5 1 0 AMC 06 AMC Thread Body size Suffix Port size 1 4 std. 3 8 std. 3 4 1 std. std. 1 2 2 std. 2 std. 3 5 6 8 9 B With bracket 1 2 14 20 1 1 02 Female Female Male Female Female Male 1 Male thread 10 1 4 Male Male Male D Drain piping

Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less.

Burst pressure Burst pressure (MPa) Note) Min. bending radius (mm) 24 20C to 60C Operating temperature Material Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.

Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.

operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5 MPa and 20C

Critical pressure ratio AS420-02 AS420-03 AS420-04 AS500-06 AS600-10 AS800-12 AS900-14 AS900-20 1/4 3/8 1/2 3/4 1 1 1 2 10 13.3 18.6 22.5 47 107 132 169 3,600 4,800 6,700 8,100 16,900 38,500 47,500 60,800 6.9 13.9 18.3 28.1 42 98 144 161 2,500 5,000 6,600 10,100 15,100 35,400 52,000 57,800 0.34 0.33 0.32 0.36 0.7 1.4 3.3 3.3 0.45 0.25 1 4 1 2 Note) Flow rate values are measured at 0.5 MPa and 20C

(Coil temperature: 20C, pressure: 0.5 MPa, at rated voltage, with light and surge suppressor, value at operation excluding restart period) The period immediately after a restart may be delayed for about 1 msec depending on operating conditions. Note 2) Use dry air to prevent condensation when operating at low temperatures.

capacity (cm3) 55 135 7 25 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (With no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Option Standard Weight (kg) 0.47 0.24 1.13 0.07 0.20 0.52 1.06 Note 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

(mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 3.8 250 5.2 340 20, 25, 32, 40 115 12.3 810 12.3 32, 40, 50, 63 810 130 40, 50, 63 80, 100 25.5 1670 25.5 1670 225 Note) Flow rate values are measured at 0.5 MPa and 20C

of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C. * This is the calculated value by changing the fluid temperature only.

LLB Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) The accessories should be mounted by user.

Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) The accessories should be mounted by user.

JIS Symbol Proportional Solenoid Specifications Applicable power amplifier VEA250, VEA251 Max. current 1 A Coil resistance 13 (20C) VER2000 VER4000 Rated power consumption 13 W (20C, with maximum current) Class H or equivalent (180C) Coil insulation type 140C (With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Model VER2000 VER4000 Mounting screw

Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.