bit 0,1 3 RESET bit 0,1 15 4 SETUP bit 0,1 5 bit 0 6 bit 0 7 bit 0 LECP6 LECA6 37 - Bit/Byte / Q_Address ID No. 0 1 16 1 063 1ABS 17 1 2INC() 18 H 2 065500 mm/s 19 L 20 3 21 2 4 2147483647 0.01mm 22 1 23 0 ID1 24 H 2 065500 mm/s2 25 L 26 H 2 065500 mm/s2 27 L 28 1 030 10% 29 1 030 10% 30 1 0255 mm/s 31 1 030 10% 32 H 2 065500 0.01mm 33 L ID2 3453 ID1 ID3 5473 ID1 ID4 7493 ID1
L 0.5m 1 1m 2 Branch connector LEC-CGD The junction cable to connect the gateway and the controller. 3 Cable between branches LEC-CG2Cable to connect the branch connector.
min(ANR) Outlet air flow rate L/min(ANR) Standard Performance conditions Purge air flow rate L/min(ANR) Inlet air pressure MPa *Note 3 0.7 25 25 Inlet air temperature oC Inlet air saturation temperature oC 1 L/min (ANR) {In the case of inlet air pressure 0.7MPa} 25 Ambient temperature oC Dew point indicator purge air flow rate Regulator construction (about Type V) Relief type Port size 3/
ZQ-OM00801-D Circuit Diagram Specifications of a Single Unit Ejector System L a L a L a t t t c h c h c h i i i L a L a L a n g n g n g 32 t t t t t t c c c y y y h h h Doc. no. ZQ-OM00801-D Pump system 33 - Doc. no. ZQ-OM00801-D Manifold Specifications Ejector System ZZQ1-BSB ZZQ1-BSC Pump system ZZQ1-OB ZZQ1-OC 34 - Doc. no. ZQ-OM00801-D Mass Ejector System Pump system 35 - Doc. no.
L L L L Fig. 7 MY1B series MY1BZ series MY1M/MY1MW series MY1C/MY1CW series MY1H/MY1HZ series MY1HT series Fig. 8 -10- When using the product that has a stroke that exceeds the stroke fine adjustment range, use an intermediate fixing spacer. Refer to the table below for the stroke fine adjustment range and the stroke adjustment range when using the intermediate fixing spacer.
Bore size(mm) Cylinder stroke(mm) 180 1569 200 998 250 813 320 495 How to order CS2 L 160 300 JR Mounting B Basic Additional symbol to cylinder L Foot J Nylon tarpaulin Boot F Rod side flange K Heat resistant tarpaulin G Head side flange Nil Cushion With cushion on both sides.
(Recommended flatness: 0.1 or less) M M M L L L L Fig. 6 Fig. 7 When using the product that has a stroke that exceeds the stroke fine adjustment range, use an intermediate fixing spacer. Refer to the table below for the stroke fine adjustment range and the stroke adjustment range when using the intermediate fixing spacer.
Keep the fluid level between H and L of the level indicator.
Basic style Rod seal Piston seal NBR CQSB12-PS CQSB16-PS CQSB20-PS CQSB25-PS 12 16 20 25 CQSB12-PS CQSB16-PS CQSB20-PS CQSB25-PS Tube gasket Long stroke CQSB12-L-PS CQSB16-L-PS 12 16 20 25 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS Set of left nos. !5, !6, !7. CQSB25-L-PS CQSB20-L-PS Seal kit includes !5, !6, !7. Order the seal kit, based on each bore size.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93
L D-M9P (Example) Nil Lead wire length 0.5 m 3 m L 5 m Z A contact protection box should be used in any of the above situations. The lifetime of the contact may be shortened. D-A72 (H) must be used with the contact protection box regardless of load styles and lead wire length. None N Applicable for the connector style (D-C) only.
("L" and "+" open) ("L" and "+" shorted) Light enters Light enters Light blocked Light blocked Lighted indicator light (Red) Lighted indicator light (Red) Light ON Light ON Light Off Light Off Time chart ON ON Output Transistor Output Transistor OFF OFF Operate Operate Load 1 (Relay) Load 1 (Relay) Return Return H H Load 2 Load 2 L L 319
rotations Number of needle rotations OUT-Exhaust Flow IN-OUT Flow OUT-Exhaust Flow Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Effective area (mm 2) Number of needle rotations Number of needle rotations Inlet pressure (MPa) IN-OUT Flow OUT-Exhaust Flow Inlet pressure: 0.5 MPa Effective area (mm 2) Flow rate (l/min
Maintenance Caution Model Connection (Flange) 2B 8B C 2B/3B/4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 X l 400 Anchor bolt M20 X l 500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 q It is not possible to indicate a definite replacement interval for the element because it varies with the odor concentration of the compressed air.
JIS symbol 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM 18mm2=1Cv Note 1) Flow rate values are at a pressure of 0.5MPa (72.5psi) and temperature of 20C (68F).
min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area mm Effective area mm Effective area mm 300 06 1.0 2 4 200 50 100 0.5 1 2 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle revolutions Number of needle revolutions Number of needle revolutions ASD530FG ASD630FG 1500 1000 14 20 12 Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area mm Effective area mm 12 10, 11 1000
A80CN 1) Lead wire symbols 0.5m: 3m: L 5m: Z : N 2) This rotary cylinder is not an improved product in water resistant ability.
tapped) l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 5 M4 x 0.7 2.5 7 M4 x 0.7 2.5 9.5 Top Mounting l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 4.8 M4 x 0.7 2.5 6 M4 x 0.7 2.5 6 Axial Mounting (Body tapped) l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 5 M4 x 0.7 2.5 6 M4 x 0.7 2.5 6 Operating Direction
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-M3 x 0.5 depth 6 (Bracket mounting screw) 7 8 47.5 2-4.5 (Bracket mounting hole) 15.5 20 25 49 4 L3 7 7 L Dimension n: Stations n L 1 35 27 13 2 54 46 32 3 73 65 51 4 92 84 70 5 6 130 122 108 7 149 141 127 8 168 160 146 9 187 179 165 10 206 198 184
lead wire Option L, M plug connector is 220 VAC at the maximum.