Note 2) V, S and R specifications are 45T or 45T1 only.
[1] Power supply input terminals, L1, L2: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor input terminal (U, V, W) to the driver power terminal (U, V, W).
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
/N.C.), 3rd Selection Vacuum V Port: 8 (Vacuum, V Port: Ø8), 3rd Selection Quantity: 4
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?
/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 1, /: /, 2nd Nominal Nozzle Size: ø0.7, 2nd Selection Supply Valve and Release Valve: N.C.
/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 2, /: /, 2nd Nominal Nozzle Size: ø1.0, 2nd Selection Supply Valve and Release Valve: N.C.
or less (With load current of 80 mA) (PF2D300, PF2W300, PF2W330) Maximum applied voltage: 30 V 2 outputs Environmental resistance Note 4) Output specifications Switch output PNP open collector Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D301, PF2W301, PF2W331) 2 outputs NPN open collector or PNP open collector (Same as switch output) Accumulated
V J Rod Cross Sectioo Rod Cover Head Cover Head Cover uNrT rNcH (MM) 4srrc SERIES NCJ2K Non-rotating Piston Rod Type: Double Acting/Singte Rod I Rod Side Flange Type (F) nc.,zxrl6G!
200 V, Other voltage (Option) Coil rated voltage (V) VNB Pressure VNC2 24 V, Other voltage (Option) 15% to +10% of rated voltage External pilot air 0.1 + 0.25 x (Operating pressure) to 0.7 MPa Refer to Graph (1).
Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-12HC1Power supply: 200/220(V)AC 10% Compatible
Output mode Hysteresis, Window comparator, Error output, Output OFF Switch operation Normal output, Reversed output Maximum load current 80 mA Switch output (SIO mode) Maximum applied voltage 30 V (NPN output) Internal voltage drop (Residual voltage) 1.5 V or less (at load current of 80 mA) Delay time*1 1.5 ms or less, variable from 0 to 60 s/0.01 s increments Hysteresis Hysteresis mode Variable
Note Accessory/Option CB-50H Petroleum, Water-glycol, Emulsion Differential pressure indicator CB-50H-V Phosphoric ester CB-51H Petroleum, Water-glycol, Emulsion Differential pressure indication switch (N.C. and N.O. common) CB-51H-V Phosphoric ester AG-12H Petroleum Blanking cap (for differential pressure indication part) AG-12H-W Water-glycol, Emulsion AG-12H-V Phosphoric ester 517 A FH100
Hydraulic fluid 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. Replacement Element Part No.
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes 24 V 100 V Relay, PLC M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes 24 V Relay, PLC M9B 2-wire 12 V Lead wire length symbols 0.5 mNil
Please contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit specifications. 1080 A 1021-AW-B Filter Regulator Dimensions J J D M N T AW20-B 1021Bracket (Option) S U Panel fitting dimension F Y R Applicable tubing 6/4 W C Q V BB IN OUT OUT K H IN Z P2 Plate thickness 10-/21-AW20-B: Max. 3.5 Pressure gauge (Option) (Pressure gauge port size) B 2 x P1 (Port