Minimum operating pressure differential 2) Install an air filter. Install an air filter close to the valve on the upstream side. A filtration degree of 5 m or less should be selected.
Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized.
Connector with cable or without cable may be selected when placing an order for the power supply cable. When only an e-con is required, place an order for it as a part.
If the operating fluid is ultra-dry air, consult SMC. 2.Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5m or smaller. 3.Therefore, take appropriate measures to ensure good air quality, such as providing an after cooler, air dryer, or water separator.
An EXH block base ass'y is used in the blocking position when ordering an EXH spacer incorporated with a manifold No. However, do not order an EXH block base ass'y because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base ass'y because it is not attached to the spacer.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized. 3.
However, never use in an atmosphere with an explosive gas since this may cause a serious explosion. 1) Secure and tighten switch mounting screws. wDo not use in an area where a magnetic field is generated. If screws become loose or the mounting position is dislocated, retighten them after readjusting the mounting position.
(Use a hexagon wrench.) (3) Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. (4) After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the auto switch. (5) When changing the detecting position, carry out in the state of 3.
Precautions Insert and pull out the connector in a straight line so that it does not tilt at an angle.
Select the proper size of cable according to an actual condition.
For connection with a load having an external support/guide mechanism, select an appropriate connection method and perform careful alignment.
If the product is used in an area with a higher voltage rating (220 or 240 VAC), select IZG10-m02 without AC power cable, and use an AC cable with an IEC 60320-C13 ground terminal connector, suitable for the power supply voltage. Power supply cable type IZG10-m03 Connect the user equipment for the power supply and external switch input according to Power Supply Cable Wiring table.
Caution Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 0.3m or smaller. Take measures to ensure air quality, such as installing an aftercooler, air dryer, or water separator. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
When the valve is open, an orange marker appears in the center of the name plate.
Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.
If resetting fails, an investigation by SMC Corporation will be required. Displayed in the case of an internal data error.