However, never use in an atmosphere with an explosive gas since this may cause a serious explosion. 1) Secure and tighten switch mounting screws. wDo not use in an area where a magnetic field is generated. If screws become loose or the mounting position is dislocated, retighten them after readjusting the mounting position.

(Use a hexagon wrench.) (3) Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. (4) After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the auto switch. (5) When changing the detecting position, carry out in the state of 3.

Precautions Insert and pull out the connector in a straight line so that it does not tilt at an angle.

For connection with a load having an external support/guide mechanism, select an appropriate connection method and perform careful alignment.

If the product is used in an area with a higher voltage rating (220 or 240 VAC), select IZG10-m02 without AC power cable, and use an AC cable with an IEC 60320-C13 ground terminal connector, suitable for the power supply voltage. Power supply cable type IZG10-m03 Connect the user equipment for the power supply and external switch input according to Power Supply Cable Wiring table.

Caution Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 0.3m or smaller. Take measures to ensure air quality, such as installing an aftercooler, air dryer, or water separator. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.

When the valve is open, an orange marker appears in the center of the name plate.

If resetting fails, an investigation by SMC Corporation will be required. Displayed in the case of an internal data error.

Option symbol Option symbol C R With an earth leakage breaker Anti-corrosive treatment fo copper tube An earth leakage breaker is installed in the air dryer. This saves additional electrical wiring at the time of installation. This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogensulfide or sulfurous acid gas.

Never use in an environment, where explosive gases are used. The switches do not have an explosion-proof rating. Never use in an environment, where explosive gases are used, as this may cause a serious explosion. 2. Mount a switch in such locations, where no vibration or shock (less than 98 m/s2) is affected. [For air] 3.

Furthermore, since valves and cylinders are not guaranteed for zero air leakage, it may not be possible to hold a stopped position for an extended length of time. Contact SMC if it is necessary to hold a stopped position for an extended time. 3.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as air grippers.

Do not apply strong impact or an excessive moment while mounting a workpiece. If an external force over the allowable moment is applied, it may cause play in the guide or an increase in the sliding resistance. LEJ LEL 8. Provide a flat surface for installing the actuator.

Otherwise, an injury or failure can result. Disassembly prohibited Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Please check the specifications before use. Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

Do not apply an impact load or strong vibration while the lock is activated. If an external impact load or strong vibration is applied to the product, the lock will lose its holding force and damage to the sliding part of the lock or reduced lifetime can result.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as air grippers.

Use it when you want to remove water but air as dry as that from an air dryer is not necessary, or when a power supply for an air dryer is not available, etc.

If an abnormal condition occurs, turn off the power supply and stop the flow of compressed air. If an abnormal condition occurs, such as smoke, a foul smell, or noise, immediately turn OFF the power supply and stop the flow of compressed air because there is a possible risk of electric shocks or fire. 2. Set the pressure of the compressed air to zero before an inspection.

After tightening by hand, tighten an additional 1/4 rotation for M3 and 1/6 rotation for M5 with a tool. However, when using a miniature fitting, tighten an additional 1/4 rotation with a tool after tightening by hand. Also, when there are 2 gaskets such as in case of a universal elbow or universal tee, tighten an additional 1/2 rotation.