Magnet: Built-in, Mounting: Rear Trunnion, Cushion: Rubber Bumper, Bore Size: 2", Stroke A: 4", +: +, Stroke B: 4", Stroke Adjustment: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Cushion: Rubber Bumper, Bore Size: 1 1/2", Stroke A: 12", +: +, Stroke B: 12", Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Foot, Cushion: Rubber Bumper, Bore Size: 1", Stroke A: 3", +: +, Stroke B: 3", Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Cushion: Rubber Bumper, Bore Size: 2 1/2", Stroke A: 12", +: +, Stroke B: 12", Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 3/4", Stroke A: 3", Stroke B: 3", Auto Switch: G59--Solid State, Gen. Purpose,3 Wire NPN, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 3/4", Stroke A: 4", Stroke B: 2", Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1", Stroke A: 4", Stroke B: 5", Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1", Stroke A: 5", Stroke B: 5", Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1", Stroke A: 7", Stroke B: 1", Auto Switch: G59--Solid State, Gen. Purpose,3 Wire NPN, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/4", Stroke A: 6", Stroke B: 6", Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 3", Stroke B: 8", Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 4", Stroke B: 8", Auto Switch: G5PW--Solid State, 2-color Indication, 3 Wire PNP, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 6", Stroke B: 3", Auto Switch: G59--Solid State, Gen. Purpose,3 Wire NPN, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 6", Stroke B: 3", Auto Switch: G59--Solid State, Gen. Purpose,3 Wire NPN, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 6", Stroke B: 6", Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 8", Stroke B: 1", Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2", Stroke A: 3", Stroke B: 3", Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 4", Stroke B: 4", Auto Switch: G5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 3m, Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 4", Stroke B: 4", Auto Switch: G59--Solid State, Gen. Purpose,3 Wire NPN, Lead Wire or Prewired Connector: 3m, Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 6", Stroke B: 10", Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 4 pcs., Stroke Options: Dual Stroke, Double Rod