Enclosure IP65 Ambient temperature range Operation: -10 to 60 oC, Storage: -20 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 250 VAC, 1 minute, Between lead block and case Insulation resistance 50 M or more at 50 VDC Between lead block and case Temperature characteristic 2% F.S. or less (0 to
. -41No.EX-OME0003-H Specification Specifications General specification Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85% RH (no condensation) Storage temperature -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Enclosure IP67 Standard CE marked (EMC directive, RoHS directive), UL (CSA) Weight 250 g or
Power supply voltage effect 1%F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC Enclosure IP40 Ambient temperature range Operation: 0 to 50 oC, Storage: -10 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC, 50/60 Hz, 1 minute, between terminals and housing Insulation
Assembly and disassembly of the SI unit -31No.EX-OMW0016-A Specification Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure
Check the tubing outside diameter, and when the accuracy of the outside diameter is +0.07mm or larger for 2, and +0.15mm or larger for other sizes, re-insert it into the One-touch fitting without cutting the tube.When the tubing is re-inserted into the One-touch fitting, confirm that the tubing goes through the release button smoothly. tube tube tube 3.2 1/8 44 or more 35 or more 25 or more
Assembly and disassembly of the SI unit -28No.EX-OMN0009-G Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure
. -10 to +50 oC Operating ambient humidity 35 to 85%RH (No dew condensation) Storage ambient temp. -20 to +60 oC Withstand voltage 500 VAC for 1 min.
Enclosure IP40 Ambient temperature range Operation: 0 to 50 oC, Storage: -20 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC or more, 50/60 Hz, 1 minute, Between lead block and case Insulation resistance 50 M or more at 500 VDC Between lead block and case Temperature characteristic 2%F.S
Fault of the SI unit or input block -25No.EX-OMP0025-A Specifications Specifications General specification Item Specifications Ambient temperature 5 to 45 oC Ambient humidity 35 to 85%RH (no condensation) Storage temperature -20 to +60 oC Withstand voltage 500 VAC, 1 minute, Between whole external and FG Insulation resistance 500 VDC, 10 M or more, Between whole external and FG Operating
Fi l t rat i on rat i ng0. 01 m ( Fi l t rat i on ef f i ci ency99. 9% ) O ut l et cl eanl i ness: 100 or l ess /f t 3 of 0. 3 m or m ore of part i cl e ( 35 or l ess / 10L ( AN R) ) Fol l ow i ng envi ronm ent s l ead to cause breakage. B roken pi eces i nj uri ng i f broken.
Fi l t rat i on rat i ng0. 01 m ( Fi l t rat i on ef f i ci ency99. 9% ) O ut l et cl eanl i ness: 100 or l ess / f t 3 of 0. 3 m or m ore of part i cl e ( 35 or l ess / 10L ( AN R) ) To get t he best perf orm ance f rom your purchase, be sure t o read t hi s m anual caref ul l y bef ore use.
Indicator accuracy 0.5%F.S. 1 digit Display method 3 1/2 digits 7 segment display, two color (red/green) indication, sampling cycle: 5 times /1 s Indicator lamp OUT1: Turns on when ON (green), OUT2: Turns on when ON (red) Enclosure IP40 Environment Operating temp. range Operation: 0 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating humidity range Operation storage: 35
/CLEAR (set using DIP switch) Internal current consumption (unit) 0.1 A or less Enclosure EX120/121/122: IP20 EX124U/D: IP65 Environment Withstand voltage 1500 VAC for 1 minute (Between external terminals and case) Insulation resistance 2 M or more (500 VDC between external terminals and case) Ambient temperature Operating temperature: 0 to +55 oC Storage: -20 to +65 oC Ambient humidity 35
Specifications General specification Item Specification Model EX140-SCS1 EX140-SCS2 Operating temperature range Operating: 0 to 55C, Storage: -20 to +65C (No freezing or condensation) Storage temperature range 35 to 85%RH (No condensation) Withstand voltage 1500VAC for 1 minute, between external terminals and ground Insulation resistance 500VDC 2M or more, between external terminals and ground
(Between FG and external terminal) Environment Insulation resistance 10 M or more (500 VDC, Between FG and external terminal) Ambient temperature Working temperature: -10 to +50 oC Storage: -20 to +60 oC Ambient humidity 35 to 85%RH (Non condensing) Operating atmosphere No corrosive gas Standard UL/CSA (E209424), CE marked (EMC directive, RoHS directive) Weight 110 g or less (Including accessories
Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal block) Ambient temperature Operating: -10 to 50 oC Storage: -20 to 60 oC Ambient humidity 35
series Enclosure IP65 (front side only when the panel is mounted), IP40 for others 6 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: 0 to 50 oC, Storage: -10 to 60 oC (No condensation) Operating humidity range Operation and storage: 35
Store in an area that is shaded from direct sunlight and has a temperature and humidity within the specified range (10C to 60C and 35 to 85% no condensation or freezing). 3. Do not apply vibration or impact to the product during storage. 2.6 Maintenance Warning 1. Do not disassemble or repair the product. Fire or electric shock can result.
Ambient temperature 0 to 40oC (No freezing) Ambient humidity 35 to 65%Rh (No condensation) Material CasePBT EmitterTungsten Standard nozzle Bypass nozzle Weight (Body) 200g 250g Standard / Directive CE Note 1) Value measured with probe of 1,000M and 5pF.
Dimensions (Port size) Semi-standard specifications With element service indicator Clearance for maintenance Optional specifications With auto Standard specifications Model Bracket mount drain P A B C D E G J M N Q R S T U V B AFM20-D 1/8, 1/4 40 87.6 17.5 21 45 21 30 27 22 5.4 8.4 60 2.3 28 104.9 AFM30-D 1/4, 3/8 53 115.4 21.5 26.5 30 50 26.5 41 35 25 6.5 13 71 2.3 32 157.1 AFM40-D 1/4,