The series MGG guided cylinder is ideally suited for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional cylinder, linear motion guide, and non-rotation device. Features include built-in shock absorbers, finite stroke adjustment, bumpers, and switch capability. Other features include: Slide or ball bushing bearings available
The MGC guide cylinder is ideal for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional linear cylinder, and a non-rotation device. Features include standard air cushions, grease nipple, and switch capability. Other features include, slide or ball bushing bearings, compact design, adjustable air cushion, and lightweight guided
Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum operating pressure: 200PSI Operating temperature range: 15 - 150°F Auto switch capable, Compact Cylinder, NCQ8, COMPACT CYLINDER, E46, 1068.77700 lb
In general, 80 to 100 mesh (150 to 180 m) filters are recommended. When transferring a coagulable liquid, take measures to prevent it from coagulating in the pump. Precautions to observe when transferring slurry Basically, it is not recommended to transfer slurry because this will result in seating failure and wearing of the check valve and accumulation of particles.
When the "move distance" setting as 150 mm. Example: if is pressed, the actuator moves to 150 mm position. Current Position if is pressed, the actuator moves to the Origin end(100mm). Origin end Opp. end 0mm 100mm 200mm 16 No. JXC#-OMA1006-B 6.3 Drive test It is possible to do the drive test in the e-Act setup tool. -Button Explanation Servo : Turn the motor servo ON or OFF.
Round cutting pliers Nominal: 125 or 150 Tightening torque: 1.4 0.1 Nm 10) Mount the bowl assembly. Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. Refer to the Check item for referential tightening torque. Actuators Modular F.R.L.
Impact/Vibration resistance (m/s2) Note) 150/50 Enclosure Dustproof Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal ON and OFF.
1 5 Port Air Operated Valve Series VZA2000 Specifications SA Fluid Air VA Operating pressure range (MPa) 0.1 to 1.0 VZA2121, 2141 2 3 4 2 3 4 VZA2 21, 2 41 0 to 1.0 SA Pilot pressure range (MPa) 0.1 to 1.0 Impact/Vibration resistance (m/s2) 150/50 Note) Base mounted VA Operating pressure Pilot pressure Note) Impact resistance: No malfunction from test using drop impact tester, to axis and
/ 200 mm, Width: 4.75 in / 121 mm, Height: 5.89 in / 150 mm, Net Weight: 8.3 lbs. / 3.8 Kg Series Configured Datasheet.
in / 150 mm, Width: 3.43 in / 87 mm, Height: 2.44 in / 62 mm, Net Weight: 1.87 lbs. / .85 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Vacuum Pump Flow Rate: 2.13 CFM / 60 LPM , 2.13 CFM / 60 LPM, Max Vacuum: 24.1 in HgV / -817 mbar , 24.1 in HgV / -817 mbar, Voltage (DC): 12, Item Dimensions: Length: 7.88 in / 200 mm Width: 4.75 in / 121 mm Height: 5.89 in / 150 mm , Length: 7.88 in / 200 mm, Width: 4.75 in / 121 mm, Height: 5.89 in / 150 mm, Net Weight: 6.5
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Oil-less Diaphragm Vacuum Pump Flow Rate: 6.5 LPM , 6.5 LPM, Max Vacuum: 26.9 in HgV / -912 mbar , 26.9 in HgV / -912 mbar, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 5.91 in / 150 mm Width: 3.43 in / 87 mm Height: 2.44 in / 62 mm , Length: 5.91 in / 150 mm, Width: 3.43 in / 87 mm, Height: 2.44 in / 62 mm, Net Weight: 1.87
in / 150 mm, Width: 3.43 in / 87 mm, Height: 2.44 in / 62 mm, Net Weight: 1.87 lbs. / .85 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
/ 200 mm, Width: 4.75 in / 121 mm, Height: 5.89 in / 150 mm, Net Weight: 6.5 lbs. / 2.9 Kg Internal Code: G0279623 Billing Code: 4XL33 Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net
, Length: 8.07 in / 205 mm, Width: 5.98 in / 152 mm, Height: 5.91 in / 150 mm, Net Weight: 14.33 lbs. / 6.5 Kg Series Configured Datasheet.
Thomas Rotary Vane Pump Max Flow: 8.5 LPM , 8.5 LPM, Max Intermittent Pressure: 450 mbar , 450 mbar, Max Continuous Pressure: 150 mbar , 150 mbar, Max Intermittent Vacuum: 50% , 50%, Max Continuous Vacuum: 15% , 15%, Motor Type: Brushless DC , Brushless DC, Nominal Voltage: 12 V DC , 12 V DC, Min.