Refer to page 8 to 10. Please note that the graph should only be used as a guide as there is a tolerance of about 10% in the clamp cylinder body.
6.7.4 Force Outputs On/Off. 6-10 6.7.5 Inactive Functions during Monitor Mode . 6-10 6.7.6 Exiting the Monitor Mode. 6-10 viii PneuAlpha 7.
Ionizer Additional air blow Air blow Ionized air 497 ZVB Series Dimensions C B D A C B A D F E [ZVB20] F E [ZVB40] Model A B C D D Note 1) E F F Note 2) ZVB20 211 202 212 310 351 210 297 341 ZVB40 248 392 298 349 390 400 384 428 Note 1) Dimension D is the overall height including the knob of the regulator.
A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .
IO-Link communication and power supply connector layout (Port Class B) BUS IN: M12 5-pin plug, A-coded No.
Cross-recessed and flat head machine screw Tightening torque M(D)HR3-10 0.2Nm M(D)HR3-15 0.3Nm Anaerobic adhesive Cover Cover Guide holder B (Cover thickness) C (screw depth) A (Screw size) D (Counterbore) E (P.C.D.)
No.EX-OMO0030-E PRODUCT NAME SI unit for PROFINET MODEL / Series / Product Number EX260 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 Configuration 16 Troubleshooting and Maintenance 26 Specifications 31 Specifications 31 Dimensions 33 Accessories
No.EX-OME0003-H PRODUCT NAME SI unit for DeviceNet MODEL / Series / Product Number EX250-SDN1 EX250-SDN1-X102 Table of Contents Safety Instructions 2 Product Summary 8 Model indication and How to Order 9 Summary of Product parts 9 Mounting and Installation 10 Installation 10 Wiring 11 Indication and Settings 17 DeviceNet objects 23 Maintenance 33 Troubleshooting 34 Specification 42 Specifications
Sets output ratio of cooling to heating to compensate difference of gain between them. 10 to 999% 6 Heating/Cooling Ensure the power supply and ground connections are made correctly. Be sure to provide the grounding.
It same for mounting bracket {Refer to Table 10 (P30)} Short Long Table 8. Tightening torqueA 1 3 5 Bore size Width across flats Tightening torque[Nm] 32,40 6 5.1 50,63 8 11.0 80,100 10 25.0 2 4 125 12 30.1 Tie rod tightening order. 26 3-2-2. Removal of seals 1) Rod seal Insert a precision screwdriver from the front of the cover to pull out the seal as shown in Fig. 10.
IN ZFC100-04 Cover B Element Cover A 1 ZFC100-06 ZFC200-06 Replacement Parts ZFC200-08 0.1 1 10 100 Description Part no.
Cold resistant cylinder (40 to 70C) w/o auto switch only Low-speed cylinder (10 to 50 mm/s) Standard Strokes Intermediate stroke (Exclusive body type) Pneumatic type Intermediate stroke (Spacer-installed type) (mm) Bore size 12, 16 20, 25 32, 40 50 to 100 Standard stroke Long stroke (Air-hydro type only) 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35
(Valve) SYJ300-10-1A .1 pc. (Blank plate ass'y) SS3YJ3-42R-03-C4 .1 pc. (Manifold base) SYJ314R-5G .2 pcs. (Valve) SYJ300-10-2A .1 pc.
How to Order 100 TAU1065 B Length per roll Indication of tube model Symbol Roll size Color indication Symbol Color 20 20m roll B Black 100 100m roll 2.4-10
Option [Actuator cable] LE CP 1 B S Cable type Cable length Nil S Robotic cable Standard cable 1.5 m 3 m 5 m 8 m 10 m 15 m 20 m 1 3 5 8 A B C Motor option Nil B Without lock With lock Produced upon receipt of order (Robotic cable only) [I/O cable] Pin no.
Stations Common supply and exhaust M a i n t e n a n c e a n d a d j u s t m e n t i s p o s s i b l e w i t h o u t d i s a s s e m b l y o f the manifold H O W T O O R D E R NZM V A C U U M E J E C T O R M A N I F O L D (N)ZZM B NUMBER OF STATIONS 01 ... 1 Station 02 ... 2 Stations to 10 ... 10 Stations EXHAUST PORT 04 ... 1/2 06 ... 3/4 PORT THREAD Nil ...PT* Remove (N) when ordering
(mm) 4 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7 Burst Pressure Characteristics Curve and Operating Pressure Tubing I.D.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
Minimum operating pressure Without auto switch: 10 to 70C Ambient and fluid temperature (With no freezing) With auto switch: 10 to 60C Piston speed 50 to 500 mm/s Same dimensions as those of the standard cylinder (Series CA2) Cushion Interchangeable Thread tolerance JIS class 2 To 250 st : 251 to 1000 st : 1001 to 1500 st : +1.0 0 +1.4 0 +1.8 0 Stroke length tolerance Lubrication Not required
Contamination and wear of emitters b. Loosening and damage of nozzles c. Twists or crushing of connected tubes d. Hardness and deterioration of connected tubes e. Air leakage 192