Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: C6H (ΓΈ6 One-touch Fitting, Straight Type)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread
+ 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: DIN rail weight) Note 1) In cases such as when many valves are operated simultaneously, supply pressure to port P on both sides and exhaust from port R on both sides, using "stations B (SUP/EXH block both sides)".
S070 M 5 B G 32 Port size Symbol 32 40 Connection Applicable tubing 3.18/2 4/2.5 Body type Barb fitting Body type Body ported stacking manifold type Symbol M Electrical entry G C Grommet Plug lead with light/surge voltage suppressor Coil voltage 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Power consumption Pressure specification Flow rate Power consumption (W) Maximum operating pressure
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., HIGH PRECISION DIGITAL PPRESSURE SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, VACUUM SWITCH, ZSE30, ZSE30A, N63, 51 lb
Temperature setting (without writing EEPROM) No 02 31 32 35 30 30 03 3F 38 0D 06 0D Set at 25.0 deg.C 31 32 Reading internal sensor No 05 32 33 32 0D 02 32 32 35 30 32 03 3F 3B 0D Answer 25.02 deg.C 33 Reading external sensor No 05 33 33 33 0D 02 33 33 30 30 32 03 3F 38 0D Answer 30.02 deg.C 34 Reading alarm status No 05 34 33 34 0D 02 34 30 38 30 03 3C 3C 0D Answer ERR11 Answer -1.52 deg.C
A1 L1 R1 U1 NDH10 U(H8) E1 MM NX Applicable bore size (mm) Applicable bore size (mm) I-02 I-03 I-04 IA-04 Part no.
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 54.00000 lb. N63.
Specifications 0.01m (95% filtered particle diameter) Outlet air filtration degree Max. 0.1mg/m (ANR) (0.08ppm) Note 1) Outlet air oil mist concentration (prior to oil saturation 0.01mg/m (ANR) or less (0.008ppm or less) Note 1) With inlet air oil mist concentration of 30mg/m (ANR) (24ppm) Applicable models IDG3V to IDG50V (standard dew point 20C) (4F)) IDG3HV to IDG50HV (standard dew point
[Tightening torque: 0.90.1N m (0.670.07ftlb] 3 Attach brackets to the manifold bases. {when equipped with brackets} [Tightening torque: 0.90.1N m (0.670.07ftlb] Note) Manifold station additions can be made in units of 2 or 3 stations.
HRS Series 6.1 Option J [Automatic fluid filling] 6-1 HRX-OM-O021 Chapter 6 OptionOptional Accessories 6.2 Option M [DI water (Pure water) piping] 6.2.1 Option M [DI water (Pure water) piping] This option is for customers who use DI water (pure water) as circulating fluid.
3585RH() CERoHS M12 3 m 02 R1/4M5x0.8 C3604+ Al2O3(96) FKM M12 103 g M12 191 g AWG23 0.72 mm 1.14 mm 4 -13No.PS-OMT0005CN-A [mA] [V] A B PSE575 02 MPa 0 2MPa PSE576 05 MPa 0 5MPa PSE577 010 MPa 0 10MPa -14No.PS-OMT0005CN-A M12 ZS-37-A 1 2 4 3 M12 ZS-37-B 3 4 2 1 M12 ZS-31-X175 -15No.PS-OMT0005CN-A Revision history A 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel:
XB13 CXT Standard part number M L Microspeed cylinder Specifications Guide cylinder
Do not drop, bump, or apply excessive impact (PSE540: 980 m/s2, PSE560: 500 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2. The tensile strength of the cord is 50 N. Applying a greater pulling force to it can cause malfunction.
5 Port Air Operated Valve Series VFRA3000 Model Configuration Port size Rc(PT) Effective area (mm2) (Cv) Pilot port size Rc(PT) Weight (kg) Valve model 1 4 3 8 37.8 (2.1) 41.4 (2.3) VFRA3111-03 VFRA3211-02 2 position double 0.71 1 8 VFRA3111-02 2 position single 0.61 1 8 1 4 3 8 37.8 (2.1) 41.4 (2.3) VFRA3211-03 VFRA3311-02 3 position closed center 0.72 1 8 1 4 3 8 34.2 (1.9) 36 (2.0) PA,