SP112X-012E P: PZ P.G.Information (Specialized Product) SMC CORPORATION 4-14-1,SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL http://www.smcworld.com Power Clamp Cylinder25 CKZT25-*-DC* Features: * Force amplification with a toggle system/ Max. clamp moment: 33Nm (Supply pressure: 0.5MPa) * The self lock functions in case of air exhaust. * Spatter proof construction Specifications How
101 kPa?1.3 to ?80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?
100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, 5 port solenoid valve, 4/5 PORT SOLENOID VALVE, VVD, 101
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 101 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 101 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, 5 PORT SOLENOID VALVE, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
Double vane type i, Actuator, Rotary, Vane Type, ROTARY ACTUATOR, 517, 101 lb
The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted., VALVE, 2POS/DBL UL CONFORMING, 4/5 PORT SOLENOID VALVE, VVD, 101 lb
101 kPa500 kPaAir/Non-corrosive, non-flammable gas12 to 24 VDC ?10%, Ripple (P-P) 10% or less (With power supply polarity protection)17 mA or less at 24 VDC5 ms or less?1% F.S. or lessEnclosureOperating temperature rangeOperating humidity rangeVibration resistanceImpact resistance?3% F.S. or less1000 VAC for 1 min.
The settings of the master pressur, 2-Color Hi Precision Dig Pres Switch, PRESSURE SWITCH, ISE40, ISE40A, 841, 101 lb
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 140, 160 , Standard stroke (mm): 10 through 300 , Through hole mount, Auto switch capable, PISTON ASSEMBLY, COMPACT CYLINDER, 493, 101 lb
10Max. 14MPaFH540-10FH541-101 1/432 (1 1/4B)120
ModelPort size Note)Rated flow rate (l/min) INLETOUTLETFH990-101 1/2B1 1/4B150
101 kPa?1.3 to ?80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type)
System: P (Vacuum Pump System, Single Unit), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: None, Pump System PE Port Female Thread: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum