13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.

Auto switches When an auto switch is mounted or its set position is changed, refer to pages 12 to 17. C a u t i o n Use a specific mounting bracket (Table 2) and mount the product so that the band of the bracket will be perpendicular to the stroke of the product. Tighten mounting screws to the appropriate torque.

Consult SMC for any causes other than those in the table above (except life) since the product may require disassembling check. 17 Revision history A[Safety Instructions] Revision of sentences.

Piping . 17 4-6. Speed controller . 17 4-7. Finger open / close speed adjustment . 18 4-8. Connection of the auto switch and sensor harness. 19 5. Operating method or operation . 19 5-1. Precautions for Design . 19 5-2. Air supply . 19 5-3. Operating environment . 20 5-4. Lubrication . 20 6.

Refer to P. 17 for the product number of the speed controller. Caution 1. Speed controller is provided with a retaining mechanism. 2. Make sure that the push-lock handle (hereinafter referred to as handle) is locked. When the orange mark is visible, the speed controller is unlocked. Unlocked state Orange mark Locked state Handle 3.

Bore (mm) Description Mounting nut Rod end nut SNPS-006 NTP-006 SNPS-010 NTP-010 SNPS-015 NTP-015 6 10 15 1.2-9 Series CJP Recommended Mounting Hole Dimensions for Plug Mounting Style Machining dimensions for Mounting When plug mounted Bore (mm) Stroke A B G F C E D 5 16 12.5 10 6 10 23 3 19.5 8.5 M10 X 1.0 17 3.5 15 30 26.5 24 5 17 13.5 10.5 10 10 23.5 4 12 20 M15 X 1.5 3.5 17 15 30.5 27

Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) a = 3000 2000 m L1 0 10 20 30 Transfer load m (kg) L2 600 400 L2 (mm) Mer Rolling Yawing m 200 L2 Mer 10 20 30 0 Transfer load m (kg) m a =1000 4000 a = 2000 L3 (mm) L3 a = 3000 2000 m Mey a 10 20 30 0 Transfer load m (kg) Refer to page 183 for deflection data. 162 17

It may cause damage to the element. 4.6-17 Micro Mist Separator with Prefilter Series AMH Construction AMH850 AMH150 to AMH650 Component Parts q Description Aluminum die cast Aluminum die cast Material Note No.

(A) 2 0.5 (With indicator light: 0.55) (A) 2 0.9 (With indicator light: 1.0) 100 V 110 V [115 V] 1.0 (With indicator light: 1.1) [1.1 (With indicator light: 1.2)] 3 (R) 1 (P) 1 (R) 3 (P) Apparent power (VA) AC 1.8 (With indicator light: 1.9) 200 V 1.9 (With indicator light: 2.0) [2.2 (With indicator light: 2.3)] 220 V [230 V] Made to Order Specifications (For details, refer to page 4-3-17

15 17 Note) Weight (kg) Valve model Body size Function Port size Rc A/B EA/EB Pilot port size VA C [dm3/(sbar)] 13 16 13 16 13 16 13 17 b 0.24 0.32 0.24 0.32 0.26 0.25 0.18 0.30 Cv 3.3 4.2 3.3 4.2 3.2 4.2 3.0 4.3 b 0.15 0.31 0.15 0.31 0.22 0.27 0.18 0.39 Cv 3.0 4.1 3.0 4.1 3.5 4.2 3.6 4.6 1 2 VSA4140-04 VSA4140-06 VSA4240-04 VSA4240-06 VSA4340-04 VSA4340-06 VSA4440-04 VSA4440-06 1 8 Rc

21 15 17 21 16 18 22 16 18 21 2.5 Single VP4150 2 position 3 position 3.3 3.0 VP4250 Double 3.8 3.6 Closed center VP4350 4.4 3.6 VP4450 Exhaust center 4.4 ( ): Denotes the normal position.

A 15 3 3 4 5 6 7 8 9 10 11 12 13 Station 5 16 17 18 19 20 21 22 23 24 25 SOL. B 16 SOL. A 4 Station 6 SOL. B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL. A 6 Station 8 SOL.

B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 8 9.2 6 15.5 5 9.2 M5 x 0.8 4 10 20.5 10 8 8 9.2 8 16.5 6 11.5 M6 x 1.0 5 16 22.5 16 10 8 9.2 10 18.5 6 15 M8 x 1.25 5 20 24.5 20 13 10 11.5 12 22.5 11 19.6 M10 x 1.25 6 25 33.5 25 17 14 16 16 28.5 12 25.4 M14 x 1.5 8 30, 40 40.5 30, 40 22 Applicable bore size (mm) Part no.

A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

However, it must be conformed to other standards if the customer provides any. 17 Electric Actuator/Maintenance Guide 2 Be sure to read before handling. Motor/Belt Mounting Side mount motor Motor assembly instructions The tightening torque of bolt indicated in the procedure is that recommended by P/A.

/O.D. mm L2 Effective area mm Body size H1 Width H2 Width Weight g Minimum bore Model D L1 When M connected across flats across flats KKH3S-50N 14 14 5/8 32.4 12.2 45.1 13.7 42.6 4.5 18.2 KKH3S-60N 6/9 49.0 18.3 5.4 1/8 17 46.9 16.5 17 44.4 KKH3S-65N 6.5/10 46.7 19.2 5.9 KKH4S-50N 14 5/8 57.8 13.7 54.1 57.1 12.2 4.5 KKH4S-60N 6/9 70.6 20.4 5.4 17 16.5 56.8 60.5 KKH4S-65N 6.5/10 1/4 19 25.4

NAN200,400 NAN500 -900 4.21 11071 NAN120-X200 Port size (NPT) M5 (NOM 10-32) Noise reduction lvax. operating pressure I 45 PS(10.2kg7c.rf) 40140.F (s -60.C) Operating temprature range Effective orifice mm2 (Cv) 5 (0.27) 20 0.1) .12 (3.3) \4/eight oz (g) 0.69 (17) Dimensions In.

The accumulated flow display unit does not change in this case. 17 Series PFA Operation Clearing the accumulated value Press the UP button while pressing the DOWN button. The accumulated value clears when the buttons are pressed continuously for 5 seconds or more. Initializing the setting In the initial setting mode , press the UP button and DOWN button for 2 seconds or more.

Offline Selection (Parameters reference) . 17 5.1 Offline Operation Procedure . 17 5.1.1 When switching from Offline state to Online state .18 5.2 Reading Parameters from saved file (Offline) . 18 5.3 Saving Parameters (Offline) . 19 1 - LECY Series / Driver Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.