2000 4400 4400 4400 9000 9000 14000 22000 22000 28000 55000 0.5 0.5 0.5 0.75 0.75 0.75 1 1 1.25 2 2 2 3 JA series Precautions 5 Be sure to read this before handling the products.
MPa Nil Without bracket B Flat bracket C L-bracket Port size Power supply voltage 0 24 VDC 1 1/8 (1000 type) 2 1/4 (1000, 2000, 3000 type) 3 3/8 (2000, 3000 type) 4 1/2 (3000 type) Communication model IO IO-Link Thread type Nil Rc N NPT T NPTF F G Refer to the Web Catalog for brackets and cables.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both stroke direction and a perpendicular direction to the stroke. (The test was performed with the actuator in the initial state.) Note 4) Allowable external resistance is the allowable resistance when flexible moving tube or similar is used.
80, 100, 125, 160, 200, 250, 320, 400, 500 1000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 1900 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 125 2000
4000 6000 00 00 5000 10 15000 2000 4000 6000 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AF60 Rc1 0.10 0.08 Pressure drop (MPa) P1 = 0.7 MPa P1 = 0.5 MPa P1 = 0.3 MPa 0.06 P1 = 0.1 MPa 0.04 0.02 0 0 5000 10 15000 Flow rate (l/min (ANR)) Specific Product Precautions Be sure to read before handling.
Applicable flow range [L/min] 1 2 0.2 0.5 5 10 20 25 50 100 150 200 300 500 600 1000 2000 2 200 5 500 10 1000 Compact, Space saving 500 L/1000 L type the volume of the current product (200 L type) Approx.1 3 200 L type 34 34 PFMB New PFMB New 73 44 73 18 30 45.2 Series PF2A (Current product) 70 116 Series PF2A (Current product) 70 116 Comparison with PFMB7201 and PF2A721-03 Comparison with
Lead wire length 46 -SCSJ3000For single solenoid: Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm 46 -DCSJ3000For double solenoid : Common specifications 46 47 For positive common For negative common For junction common How to Order Indicate the part no. of the connector assembly for the manifold and solenoid valve.
VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA SFD 1000 2 1 kVA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) LLB Singlephase 2 kVA 2000
(SCFM) FLOW AIR 3/32 *OIL FLOW (GPM) 4.0 200 1/16 3/32 3.0 150 1/16 3/64 100 2.0 3/64 1/32 1/32 50 1.0 0 3000 2000 1000 0 0 1000 2000 3000 0 (PSIG) PRESS . INLET PRESS . (PSI) *S.G. = .85 DROP OUTLET PRESS . = " O" PSI 31 SERIES 50 EW (5 WATTS AC & DC) MINIATURE HAZARDOUS LOCATION VALVES! Meet todays demands for economy of space and energy consumption.
CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000
No.PB19PB20 12 00 OFF PB03 0 PB04 FFC 100 100%1s 0 0 100 PB05 500 PB06 GD2 1(6.1.1)0100.0 No.PA0823 7.0 0 300.0 PB07 PG1 12 No.PA0803 24 rad/s 1 2000 5 14 5 No.
Stop position (positioning start address) Movement amount: 2000 Movement amount: 2000 Da.8 Command speed Set the command speed for positioning. (1) If the set command speed exceeds "Pr.8 Speed limit value", positioning will be carried out at the speed limit value. (2) If "-1" is set as the command speed, the current speed (speed set for previous positioning data No.) will be used for positioning
Stop position (positioning start address) Movement amount: 2000 Movement amount: 2000 Da.8 Command speed Set the command speed for positioning. (1) If the set command speed exceeds "Pr.8 Speed limit value", positioning will be carried out at the speed limit value. (2) If "-1" is set for the command speed, the current speed (speed set for previous positioning data No.) will be used for positioning
When the controller is turned ON next time, default value (January 1st, 2000. 00:00:00) will be set. Therefore, the date and time must be set again. [How to set the Date and Time] a) Mode change Change the mode to Remote mode in the main window.
Cable colour: Signal 1 Yellow : TD+ Connector M12 Straight M12 Straight 2 White : RD+ Cable O.D. 6.5 mm 3 Orange: TDNominal cross section AWG22 4 Blue : RDMin. bending radius (Fixed) 19.5 mm Fig. 9-4 EX9-ACxxxEN-PSPS -37No.EX-OMY0014-A (5) Cable with communication connector (M12 M12, Angle) Part number: EX9-AC 005 EN-PAPA Cable length (L) 005 500 [mm] 010 1000 [mm] 020 2000 [mm] 030 3000
-1.05 16.80 Psi 0 232.06 -15.2 243.7 (PD) 1000 5000 738 5200 ISE70 MPa (PD) PD [MPa] (PD)(ISE70 MPa) -62No.PS-OMV0003CN-G Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.002549 -2.549 ISE70 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa 0.0004 -0.4 kPa 0.4 -400 kgf/cm 2 0.004079 -4.079 ISE71 bar 0.004 -4 psi 0.05802 -58.02 [] (ISE70 MPaPD=2000
) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25[MPa] (ISE70GMPaPr=0.75[MPa]) (PD) = (Pr b) / a = [0.75 (-0.25)]/0.00025 = 4000 -66No.PS-OMV0008CN-E IO-Link IODD IODD(I/O Device Description) IODD logo IODD IODD 1 ISE70G SMC-ISE70G-ymmdd-IODD1.1 2 ISE75G SMC-ISE75G-ymmdd-IODD1.1 3 ISE76G SMC-ISE76G-ymmdd-IODD1.1 4 ISE77G SMC-ISE77G-ymmdd-IODD1.1 5 ISE78G SMC-ISE78G-ymmdd-IODD1.1 "ymmddy
value PD: Pressure gauge measurement value a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Inclination a Intercept b MPa 0.0125 -12.5 kgf/cm2 0.127475 -127.475 ISE79S bar 0.125 -125 psi 1.813 -1813 [Calculation example] (1) Conversion from the process data to the pressure measurement value (For ISE79S series, unit specification MPa and PD = 2000
DC (+) q 6 Red CH3_OUT1 5 Gray CH2_OUT1 4 White N.C. 3 Black CH1_OUT1 2 Blue DC() 1 Brown DC(+) DC () w CH1_OUT1 e N.C. r CH2_OUT1 t 2000 CH3_OUT1 y CH4_OUT1 u N.C. i Internal circuits and wiring examples PF2A200 PF2A201 DC (+) DC (+) 4 3 2 1 4 3 2 1 (Brown) (Brown) Sensor Sensor Sensor + Load Load Load Load + NC NC 24 VDC CH1_OUT1 CH1_OUT1 24 VDC (Black) (Black) 4 3 2 1 4 3 2 1 Load Load