DC AC, DC 60 40 1 80 60 10(1) 40 60 60 40 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
Note 4) Since this is a special product, a manifold part number is not specified.
A 1 () () A 2 LECSCSeries/ / *3) 1 1.5 3) 1 1 () A 3 1. 15P()-N() 2. L1L2L3(MC) (MC) 3. () () A 4 4.
(Rotation range of single flat (key) when mounting 2 stopper blocks on the other sides groove is the opposite side from
MM Relief port FX 20, 25 Eh8 D FZ I 20 to 32 Standard port Relief port Width across flats NA 4-FD 45 1.5 AL 32, 40 A F N K N S + Stroke FT H FY Z + Stroke ZZ + Stroke 40 (mm) 4 7 FD E 20-0.033 0 52 40 40 34 B FX FZ FY G FT 13 8 AL D K MM NA NN B1 B2 Bore size ZZ Z H H2 H1 S P N I F C2 A 66 60 60 60 75 75 75 11 8 8 8 40 32 25 20 24 22 22 18 50 45 45 41 8 8 8 6 6 5 22 17 17 13 41 32 32 26
When using as a stopper, select a model with 30 stroke or less. 2.
65 70 75 80 115 140 45 50 55 60 65 70 75 80 85 120 145 30 35 40 45 50 55 60 65 70 75 30 35 40 45 50 55 60 65 70 75 110 135 M5 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 115 x 140 M6 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 85 x 120 x 145 M5 x 30 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 M5 x 30 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 110 x 135 M3 x 25 x 30 x 35 x 40 x
Mineral oil A A A C A A 18 Sodium hypochlorite (2%, Room temperature) A C D A D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B D A A B 23 Unless noted otherwise, the solution concentration is in a saturated state.
Mineral oil A C A A A A 18 Sodium hypochlorite (2%, Room temperature) A C A D D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B A D A B 23 Unless noted otherwise, the solution concentration is in a saturated state.
, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 RS H A Intermediate strokes by the 1 mm interval are available without using spacers for stroke adjustment.
, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 RS H A Intermediate strokes by the 1 mm interval are available without using spacers for stroke adjustment.
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption W (Holding) Temperature rise (C ) (Rated voltage) 4.5 45 3.2 35 6 55 7.5 60 6 50 8 60 11 65 9.5 60 11.5 65 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage. Changing a coil from AC to DC is possible, but it's impossible to change from DC to AC.
Fingers synchronized by a rack and pinion mechanism Model/Stroke Max operating frequency (c.p.m) Opening/closing stroke (L2L1)(mm) Weight (g) Width at closing (mm) (L1) Width at opening (mm) (L2) Bore size (mm) Model Built-in dust proofing mechanism 60 20 40 60 30 60 80 40 80 100 50 100 120 70 120 160 100 160 200 56 78 96 68 110 130 82 142 162 100 182 200 150 198 242 188 246 286 76 118 156
Order a pressure gauge separately. AW30K to 60K Filter Regulator with Backflow Function Spacer T-bracket spacer For 30 to 60 Y30 to 60 Y30T to 60T For Air Combination (Modular connection bracket) Order a pressure gauge separately. IR1000 to 3000 Precision Regulator This is not completely copper-free since the electric circuit is included. (Wetted parts are copper-free.)
valve port Rc 3/8 Safety valve port Rc 3/8 250 A (mm) A 60 130 VBAT05 VBAT10 Tank model 17 Air Tank Series VBAT Dimensions: CE Certified Product VBAT05A-Q Material: Carbon steel Connected to VBA10A, 11A Safety valve port Rc 3/8 Tank IN port Rc 3/8 Booster regulator IN port Rc 1/4 Spare port 2 x Rc 1/2 EXH: Rc 1/4 60 60 OUT (370) (307) Tank OUT port Rc 3/8 257 156 163 4 x 11 32 32 100 Drain
(mm) Symbol 1 2 3 Note 2) Port size Rc 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking
30 60 80 40 80 100 50 100 120 70 120 160 100 160 200 60 10 40 MHC 60 MHT 16 40 MHY 60 MHW 20 40 MRHQ 60 25 Misc. 40 30 D32 20 2030 40 P . 12-4-7 20 Note) The open and close time spans represent the value when the exterior of the workpiece is being held.
When a workpiece could be deformed during adsorption or transportion. (Example of a cardboard box) When the adsorption surface of a workpiece is slanted.
[Check valve] A check valve is a safety device intended to prevent reverse flow. The AP 64 is a unique design with only one moving part in the gas stream, an O-ring. It is a springless design, free of springs and poppets. [Vacuum generator] A venturi device that creates vacuum by flowing gas through a nozzle.
No need for a tube-type heat exchanger. No need for a tubetype heat exchanger. Can directly control temperature of chemicals.