Basic type, Axial foot type, Front flange type, Rear flange type, Integral clevis type Mounting JIS symbol Double acting/Single rod Standard Strokes (mm) Note 1) Standard stroke Long stroke Bore size 25, 50, 75, 100, 125, 150, 200 201 to 350 20 Minimum stroke for mounting auto switches 301 to 400 25 301 to 450 32 Number of auto switches Model 301 to 800 40 25, 50, 75, 100, 125, 150, 200, 250

P D N A Non-lube/Rubber bumper Non-lube/Air cushion MLGP RLQ Bore size 20 25 32 40 20 mm 25 mm 32 mm 40 mm Cylinder stroke (mm) With rod boot MLU Bore size (mm) Standard stroke (mm) Long stroke (mm) Without rod boot Nylon tarpaulin Heat resistant tarpaulin 20 Nil J K ML1C 25, 50, 75, 100, 125, 150, 200 201 to 350 D25 32 40 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200, 250

DBoth directions Locking direction Minimum Stroke for Auto Switch Mounting Standard Stroke -X 20No. of auto switches mounted 2 Max. manufacturable stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm)(1) Model Long stroke (mm) 1 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 Data D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250

Nil S n Bore size/Stroke (mm) Stroke (mm) Bore size (mm) 15 25 50 75 100 125 150 175 200 250 300 Auto switch Nil Without auto switch (Built-in magnet) 12 16 20 25 32 40 For the applicable auto switch model, refer to the table below. Option Adjusting bolt with bumper only (Standard) Nil With 2 shock absorbers (Set on the driving cylinder side only when packed.)

Left side parallel Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 Symbol Type NZ Mounting type Z NY Mounting type Y NX Mounting type X NW Mounting type W NV Mounting type V NU Mounting type U NT Mounting type T NM1 Mounting type M1 NM2 Mounting type M2 * Refer to the applicable stroke table. w Size 25 32 40 Applicable Stroke Table : Standard Stroke [mm] Model 50 100 150 200 250

Specifications FGH200 FGH300 Model FGH100 Number of built-in elements (element length) (mm) 1(125) 1(250) 1(500) Operating pressure MAX. 1 MPa Operating temperature MAX. 80C (Not above the boiling point) Each kind of fluid (See the table of applicable fluids on pages 63 and 64) Applicable fluid Port size (Rc) 3/8, 1/2, 3/4, 1 Stainless steel 316 (Electrolytic polishing) Housing Material PTFE

Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range Note 4) 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160 mA or less 170 mA or less 290 g 150 mA or less 250

71000 1100 2500 4400 11000 18000 28000 36000 55000 1000 2000 4400 9000 14000 22000 36000 55000 0.5 0.5 0.5 0.5 0.5 0.5 0.75 1 1.25 2 2.5 3 Basic type, Flange type, Foot type Mounting Operating range Center of sphere Operating range Axial center 5 Semi-standard/Thread nominal size -5 to 60C JA20-8-100 JA25-10-150 JA32-10-100 JA40-12-125 JA40-12-150 JA40-12-175 JA50-16-150 JA63-16-200 JA80-20-250

Standard Strokes Bore size [mm] Standard stroke [mm] 1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.

N.O. 125 AC 250 AC 30 DC 125 DC 5 3 4 0.4 3 2 3 0.4 1.3 0.8 2.5 1.5 0.7 0.5 1.5 1 3 0.05 2 0.05 0.1 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 1500 VAC, Hz for 1 min.

Battery life 12 months continuous operation (Without backlighting, temperature conditions: at 25C) Response speed 250 ms Display accuracy 2% F.S. or less (Temperatue conditions: at 25C) Repeatability 1% F.S. or less (Temperatue conditions: at 25C) Temperature characteristics 3% F.S. or less (0 to 50C with 25C standard) Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

40, 50, 63, Standard stroke (mm): 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, Rc, NPT or G port threads, Clean series, AME NO SIZE RAPART, AIRLINE EQUIPMENT, AME SUPER MIST SEPARATOR, 21, AME NO SIZE RAPART, 2.40722 lb

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

. *, various mounting configurations, cushion for noise damping.Air cylinder, double rod, non-lube type, Bore sizes *: 125, 140, 160, 180, 200, 250, 300, Mountings: basic, foot, flange, trunnion, Rod boots and cushions available, Auto switch capable for 125mm~200mm bores, CYL, AIR, DBL ROD, NON-LUBE, ACTUATOR, CS1/CS2 TIE ROD CYLINDER, XW, 200MM CS1 DOUBLE-ROD, .00000 lb, SeriesDescriptionModelActionNoteVol