SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2G16-150AZ-W-A"

Extend the dimensions of A, H. when using a single/double knuckle joint together with a rod end nut. (To extend dimensions A/H, refer to the table below, and specify the product as Made-to-order -XAO.) Pin and cotter pin are attached for double knuckle joint.

A model should be selected with a gripping force of 7 to 14 times that of the component weight. If high acceleration, deceleration or impact forces are encountered during motion, a further margin of safety should be considered.

Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 2 Calculate corrected air flow by using A or B and C. Corrected air flow = (Air flow) (Data A x Data C) Corrected air flow = (Air flow) (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow.

Note 2) For 25 stroke, the shock absorber is mounted on a single side of the plate.

Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 20 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor do not dangle it from the cord. 3. Do not exceed the screw-in torque of 3.5 Nm when installing piping.

Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.

to 60 Hz only Cooling method A W Air-cooled refrigeration Water-cooled refrigeration When multiple options are combined, indicate symbols in alphabetical order.

Drip failure can cause damage to the components that need lubrication. 14-2-62 Lubricator Series AL10 to 60 Construction AL10 AL20 JIS Symbol w w e q q t IN OUT IN OUT F.R.L. y y AV r u u AU AF AR AL30/40 AL50/60 IR w w q t VEX q e e t AMR IN OUT OUT IN ITV y r IC i r u VBA VE VY1 y G u PPA AL Component Parts Description Material Note No.

5 q t t r u u i i r y y w !6 w Meter-in type Meter-out type Meter-out type Meter-in type Seal method: Face seal For G thread e o !3 !1 !0 !4 !2 !5 q t u i r y !7 w Meter-in type Meter-out type Component Parts No.

5 q t t r u u i i r y y w !6 w Meter-in type Meter-out type Meter-out type Meter-in type Seal method: Face seal For G thread e o !3 !1 !0 !4 !2 !5 q t u i r y !7 w Meter-in type Meter-out type Component Parts No.

G The lead-wire length for a valve with a lead-wire is 300 mm. When in need of a valve with a lead-wire longer than 600 mm, place an order for a valve without a connector and connector assembly.

^-'-t" +'' l' tv."' 2',Sr " ,:; . a . ' li'J.Sh.' A--T.Tr/ir.{ 8r " 4 ' l e A . a ' A . , .

or more for Air pressure lock-up Sol A, B & C accept direct-operated type or pilot operated type. As you find that Solenoid valve Sol A for lock releasing is independent, you can use a compact 3-way valve and mount it dkeclly io lock-po[i by means of a nipple so that you can get the time delay of locking as short as possible. Diagram 6.

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

L32 pin clamp cylinder available O Compact design makes it applicable to a broad range of workpieces. OContributes to a lightweight jig.

SP ZCUK (mm) W B D-A9, D-A9V D-M9, D-M9W D-M9V, D-M9WV Bore size (mm) AMJ B A W 16.5 A B W A 10 16 20 25 32 0.5 7.5 2.5 7.5 3 12.5 16.5 1.5 (1) AMV 0 8 1.5 8 20 4 16 20 2 (0.5) 2 10 0 10 24 6 20 24 4 (1.5) AEP 3.5 11.5 1.5 11.5 26.5 7 22.5 26.5 5.5 (3) 4.5 12.5 2.5 12.5 27.5 8 23.5 27.5 6.5 (4) HEP Note 1) Figures in the table above are used as a reference when mounting the auto switches

Note: The orientation of a connector can be changed arbitrarily, depending on the combination of a housing (4) and a terminal box (3).

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

D-F9BAL Bore size (mm) D 18.5 16 -9 -6 -4 -3.5 B 2 9 12 14 14.5 C 0.5 10.5 16.5 24 25 34 A 18.5 28.5 34.5 42 43 52 6 10 15 20 25 32 A C Electrical entry direction: Inward Electrical entry direction: Outward Auto Switch Mounting Dimensions (mm) CXSJ6, 10 C3 Bore size 6, 10 0.4 0.4 7.2 4.8 7.2 4.8 B1 Symbol Auto switch model C2 D2 D1 A1 B1 C1 C2, C3 D1 D2 D-A9 D-F9, D-F9 W,D-M9 C1 A1 D-A9V

VZ (A) 2 (A) 2 VS 3 (R) 1 (P) 3 (R) 1 (P) r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts Material Description Notes No. Aluminum die cast Body q Stainless steel Spool/Sleeve Metal seal w Aluminum/NBR Spool valve Rubber seal Resin Piston e Pilot valve r 2.10-7