Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.48606 lb,
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.82668 lb,
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Remote type display unit , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH
sResponse timeHysteresisPower supply voltageResistancePF2W711Water7 to 110 l/min7 to 110 l/min10 to 100 l/min1 l/min1 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less1150 g3/4, 1Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
sResponse timeHysteresisPower supply voltageResistancePF2W740Water3.5 to 45 l/min3.5 to 45 l/min5 to 40 l/min0.5 l/min0.5 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
sResponse timeHysteresisPower supply voltageResistancePF2W740Water3.5 to 45 l/min3.5 to 45 l/min5 to 40 l/min0.5 l/min0.5 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
sResponse timeHysteresisPower supply voltageResistancePF2W740Water3.5 to 45 l/min3.5 to 45 l/min5 to 40 l/min0.5 l/min0.5 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
sResponse timeHysteresisPower supply voltageResistance--Real-time flow rateAccumulated flowSwitch outputAccumulated pulse outputEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistancePF2W740TWater, Mixture of water (50%) and ethylene glycol (50%)3.5 to 45 l/min3.5 to 45 l/min5 to 40 l/min0.5 l/min0.5 l/pulse0 to 90C (
sResponse timeHysteresisPower supply voltageResistance--Real-time flow rateAccumulated flowSwitch outputAccumulated pulse outputEnclosureOperating temperature rangeWithstand voltageInsulation resistanceVibration resistanceImpact resistanceNoise resistancePF2W740TWater, Mixture of water (50%) and ethylene glycol (50%)3.5 to 45 l/min3.5 to 45 l/min5 to 40 l/min0.5 l/min0.5 l/pulse0 to 90C (
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8
Using SMC speed controls with built in one-touch fittings minimizes installation time, reduces mounting height and enables a more compact machine design. These speed controls allow the body to be rotated to facilitate simple installation. Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, EXHAUST CLEANER, CLEAN ROOM, AIRLINE EQUIPMENT, AMP CLEAN ROOM EXHAUST CLEANER, FB, AMP 1/2INCH STANDARD (PT), 2.98848 lb, ModelThread typePort sizeOptional 1/43/81/23/4AMP420Rc NPTG----??--
Rated flow range [L/min] Model Min. Max.
L eading to the failure of pump. 5 . Replacement parts C aution S tart & S top S ee C ircuit E xample 1 C onnect air piping to the port A IR S UP, and transported fluid piping to the suction port F L UID IN and the discharge port F L UID OUT respectively. S et pilot air pressure in the range of 0 .2 MPa and 0 .7 MPa(2 to 7 .1 kgf/c )by using regulator.
S 1 0.53 28 2.511 48 418 6.531.5 6.531.5 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW KFNW KDN SUS316L,SUS304,FKM 2 MPa G 0.40.7[ ] 46 200 360 660 1350 3000 5150 3 3 cm O.5MPa 2.5 12 15.5 30 42 54 54 M5 Rc1/8 Rc1/4 [kg] 0.5 1.2 1.8 3.4 5.6 11.5 20 1 2 [Y-VAC2] 5 3 1 1mm 32 L/SP=0.1MPa 30 6 P11) 28 XLD-100 XLD-160 L/s () P=0.1MPa 26 24 22 20 XLD-63 XLD-80 18 16 14 XLD-50 12 10
MGP M 25 30 M9BW M L A S 2 S 1 n n ( 12 12mm 40 40mm 16 16mm 50 50mm 20 20mm 63 63mm 25 25mm 80 80mm 32 32mm 100 100mm A (MGPM,L,A 16100) M5X0.8 Rc N NPT TF G (mm) 2. (mm) MGP12,16,20,25,32,40,50,63,80,100 MGP-A 16,20,25,32,40,50,63,80,100 MGPS50,80 3.
Measures should be taken to protect against human injury and machinery damage in the event that there is a loss of air pressure, electricity or hydraulic power. l. Condition that the products are deformed by force or weight applied. 2. Do not close any objects which are affected by magnets.