Model AC20, AR20, AR20K, AW20, AW20K, AWM20, AWD20 AR20P-580AS AC25, AR25, AR25K AR25P-580AS AC30, AR30, AR30K, AW30, AW30K, AWM30, AWD30 AR30P-580AS AC40(-06), AR40(-06), AR40K(-06), AW40(-06), AW40K(-06), AWM40, AWD40 AR40P-580AS e Tighten the bolt.
AR30 AR40 Accessories Panel Mounting Nut (Optional) AR20P-260S AR30P-260S AR40P-260S Mounting Bracket Kit (Optional) AR20P-270AS-X48 AR30P-270AS-X48 AR40P-270AS-X48 Model AR20 AR30 AR40 D E 2 A C F IN OUT AA H P J Q V S W K U T Bracket and Mounting Nut (Optional) PANEL FITTING IN OUT X Z Y Plate Thickness AR20, 30: Max 3.5 AR40: Max 5 8 Series AL20~40 Lubricator How To Order AL 20 N 02 B
AR30 AR40 Accessories Panel Mounting Nut (Optional) AR20P-260S AR30P-260S AR40P-260S Mounting Bracket Kit (Optional) AR20P-270AS-X48 AR30P-270AS-X48 AR40P-270AS-X48 Model AR20 AR30 AR40 D E 2 A C F IN OUT AA H P J Q V S W K U T Bracket and Mounting Nut (Optional) PANEL FITTING IN OUT X Z Y Plate Thickness AR20, 30: Max 3.5 AR40: Max 5 8 Series AL20~40 Lubricator How To Order AL 20 N 02 B
Specifications 1) Standard dew point: -20oC, -15oC 2) Standard dew point: -40oC, -60oC Model Specifications IDG3V4 IDG5V4 IDG10V4 IDG20V4 IDG30AV4 IDG50AV4 IDG3HV4 IDG5HV4 IDG10HV4 IDG20HV4 IDG30HAV4 IDG50HAV4 AFM30-A AFM20-A AFM40-A AFM30-A AFM20-A AFM40-A Mist separator AFD40-A AFD30-A AFD20-A AFD40-A Micro mist separator AFD30-A AFD20-A Component equipment AR20-B Regulator AR40-B AR25-
Caution: Spacer (Y200-A) Regulator (AR20 series) WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Wiring Manual lock Discrete wiring method Valve closed (Vertical slit) Valve opened (Horizontal slit) SUP port Rc, NPT, G1/4 Make sure that the screw is in the valve closed position during normal operation.
AR20 and AW2000 are recommended for the pilot regulator. URL http://www.smcworld.com Akihabara UDX 15F Phone: +81 3 5207 8249 Fax: +81 3 5298 5362 Specifications are subject to change without prior notice and any obligation the part of the manufacturer. 2012 SMC Corporation All Rights Reserved parts before returning to SMC.
Example) AR20-02E-1-B-X2175 Under the New Measurement Law, this type is only sold outside Japan. (The SI unit is used inside Japan.)
indicator purge air flow rate *Note 1 *Note 1 -20 -15 *Note 2 Standard performance conditions 0.7 25 25 25 1L/min (ANR) {In case of inlet air pressure 0.7 MPa} *Note 3 1/8 1/4 Port size Mass kg (With bracket) 0.25 (0.31) Model Specifications IDG3M4 IDG5M4 IDG3HM4 IDG5HM4 IDG3V4 IDG5V4 IDG3HV4 IDG5HV4 Mist separator Micro mist separator AFM20-A AFD20-A Component equipment Spacer Y200(T)-A AR20
AC20B-D to AC60B-D Model AC20B-D AC30B-D AC40B-D AC40B-06-D AC50B-D AC60B-D Filter [AF] AF20-D AF30-D AF40-D AF40-06-D AF50-D AF60-D Component Regulator [AR] AR20-D AR30-D AR40-D AR40-06-D AR50-D AR60-D Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Pressure gauge port size Note 1) 1/8 [AR] Fluid Air Ambient and fluid temperature Note 2) -5 to 60 oC (with no freezing) Proof pressure
-A AFM20-A AL20-A AR20-A AFM20-A AL20-A AR20-A AF30-A AF30-A AF30-A AC25*-A AR25-A AFM30-A AR25-A AL30-A AR25-A AF30-A AF30-A AW30-A AF30-A AW30-A AC30*-A AR30-A AFM30-A AL30-A AR30-A AFM30-A AL30-A AR30-A AF40-A AF40-A AW40-A AF40-A AW40-A AC40*-A AR40-A AFM40-A AL40-A AR40-A AFM40-A AL40-A AR40-A AF40-06-A AF40-06-A AW40-06-A AF40-06-A AW40-06-A AC40*-06-A AR40
AR20 02G 02E 1 1 A B Piping specifications Flow direction Piping specifications Flow direction Nil Rc1/4 F G1/4 *1 Nil Flow direction (Left Right ) R Flow direction (Right Left) Nil Rc1/4 F G1/4 *1 Nil Flow direction (Left Right ) R Flow direction (Right Left) *1: Conforming to ISO16030 *1: Conforming to ISO16030 Square embedded type pressure gauge Round type pressure gauge Refer to
-0 VR4152-01A-1 VR4152-01B-0 VR4152-01B-1 W/o sub-plate W/ sub-plate Side piping W/ sub-plate Bottom piping VR4152 Double pilot Precautions Construction VR4151 VR4152 Be sure to read before handling.
AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR50(K) AR40(K)-06 AR60(K) No.
-B AFM20-A AL20-A AR20-B AFM20-A AL20-A AR20-B AF30-A AF30-A AF30-A AC25*-B AR25-B AFM30-A AR25-B AL30-A AR25-B AF30-A AF30-A AW30-B AF30-A AW30-B AC30*-B AR30-B AFM30-A AL30-A AR30-B AFM30-A AL30-A AR30-B AF40-A AF40-A AW40-B AF40-A AW40-B AC40*-B AR40-B AFM40-A AL40-A AR40-B AFM40-A AL40-A AR40-B AF40-06-A AF40-06-A AW40-06-B AF40-06-A AW40-06-B AC40*-06-B AR40-
AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR50(K) AR40(K)-06 AR60(K) No.
Please read and understand the cautions in the Operation Manuals for VX2 series (2 port solenoid valve) and AR20 series (Regulator) before use. -6No.PS-OMR0002-K 2 About this product Features The Gap between the detection surface and the workpiece (0.01 mm to 0.03 mm, 0.02 mm to 0.15 mm, 0.05 mm to 0.30 mm) can be detected.
DC_UPLOAD_REQ 0x54 01b(1)(single shot) (1) 0xFF91 (Notification) -30No.EX-OMZ0018 8.
Please read and understand the cautions in the Operation Manuals for VX2 series (2 port solenoid valve) and AR20 series (Regulator) before use. -6No.PS-OMT0002-E 2 About this product Features The Gap between the detection surface and the workpiece (0.01 mm to 0.03 mm, 0.02 mm to 0.15 mm, 0.05 mm to 0.30 mm) can be detected.
Example) AR20-02E-1-X2025 Valve specifications Coil specifications Standard Specifications AR20 Model Port size Fluid Proof pressure Maximum operating pressure Set pressure range Gauge port size 1 4 Air 1.5 MPa 1.0 MPa 0.02 to 0.2 MPa Note 2) Vibration resistance/Impact resistance m/s2 1 8 Note 1) Rated voltage Allowable voltage fluctuation Type of coil insulation Power consumption Apparent
7 278 247 246 252 272 Note) The total length of B dimension is the length when the filter regulator handle is unlocked. 72 Options Digital Pressure Switch ISE35 N 25 M L A Applicable Series AC20, AC25, AC30, AC40, AC50, AC55, AC60 AC20A, AC30A, AC40A, AC50A, AC60A Symbol Description F.R.L. unit AC20B, AC25B, AC30B, AC40A, AC50A, AC55B, AC60B AC20C, AC25C, V30C, AC40C AC20D, AC30D, V40D AR20