Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less
Rc1/8 [2 ] 0.64 (1) (0.1MPa) (2) IR3000:0.2MPa (3)2 ON-OFF () (4) 4- (C) (C) (A) (A) (C) (A) (C) BLEED SUP OUT SU P N/ M Pa/ ( S) N N m 1 1 M Pa/m ( ) m 2 M Pa M Pa (A) /N (B) / ( ) m 2 ( A ) m 2 5- I R 3 0 0 1 SUP OUT 2 3%F.S. 3 R B(P36203018) G 2 3 RcF N IR3000G43-2-01 G43-P2-N01-X30 IR3010G43-4-01 G43-P4-N01-X30 IR3020G43-10-01 G43-P10-N01-X30 02:1/4 03
3 Component Parts No. 1 2 3 4 5 6 7 8 9 Description Description Material Aluminum die-cast Aluminum die-cast Rolled steel Aluminum alloy Brass Aluminum alloy Aluminum alloy Aluminum alloy Brass Material Stainless steel H-NBR Stainless steel Note Note Urban gray Urban white Nickel plated No. 10 11 12 13 14 15 16 17 18 Cover Body Plate Spool valve Orifice Valve seat Valve guide B Valve guide
(Default setting) Number of occupied valve 8 outputs Number of occupied valve 16 outputs Number of occupied valve 24 outputs Number of occupied valve 32 outputs Mode OFF OFF OFF ON ON ON 1 2 3 4 5 6 7 8 ON 2 1 0 1 ON/OFF : : Mark C on the unit Mark B at cable end Mark A at cable end OFF OFF ON (1) Input data + System diagnosis + Unit diagnosis (up to 10 units) Input data + System diagnosis
URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA
Specifications Table 4 Model Note 1 XMH-16 XMH-25 XYH-25 XMH-40 XYH-40 XMH-50 XYH-50 Flange (valve) size 16,CF034 25 40,CF070 50 Actuating type Manual Fluid Inactive gas under vacuum Operating temperature oC 5 to 150 Operating pressure Pa (abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures ,
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series
Tubing Size Symbol Type Body Class Tubing outside diameter Metric size 4 04 6 06 8 08 10 10 1/8 03 3/16 05 1/4 07 3/8 11 1/2 13 3 J Inch size Table 2. AC Insert Pin. Holder Assy Model Number LQ-GPJ LQ-GPJ-N LQ-GPJS LQ-GPJS-N LQ-GJLQ-GJ-NLQ-GJSLQ-GJS-NLQ-GC Larger Diameter Tubing How To Order LQ GC Nil B None With bracket Type Table 1.
ISO Standards [ISO/21287] Compact Cylinder 20,25,32,40,50,63,80,100 Series C55 How to Order B 20 10 C55 B 20 10 M9B S CD55 With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
50 55 Reverse rotation suppression input Alarm reset input PG output C phase 0V Servo alarm output 0V Frame ground 65 75 For LX Positioning complete signal output 0V External power supply input A 50 50 Driver model SGDE-A3BP SGDE-A3AP B 55 55 Example for driver connection between equipment +10% 15% +10% 15% Single phase 200 to 230VAC (50/60Hz) For 100V Single phase 100 to 115VAC (50/60Hz
L 46 (24) Double pipe nozzle AIR OIL D C B 12 E A 24 9.5 2 3 57(Max.) 12.5 AIR SMC 27.5 4 10 40 23.5 OIL L Dimension (mm) 20 200 25 250 30 300 35 350 7.5 2 x 4.5 20 4 Symbol Length 17 T0425 (4 x 2.5) Applicable tubing T0604 (6 x 4) Applicable tubing Cross section ABCDE Main Parts List Description Material Aluminum die-casted No.
(Including O-ring for element) 5 m 10 m 20 m Model FH150-02 FH150-03 FH150-04 Element size EP910-005N EP910-010N EP910-020N 55 x 90 Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type. N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion (10 m only) Note 2) Refer to page 528 for micromesh elements.
How to Order ARJ 3 10 01 X204 B 0.4 MPa Setting (For moderate pressure) X204 Made to Order Body size Model Semi-standard Relieving type 10 Thread type Nil 1 S 0.7 MPa setting (Standard) 0.2 MPa setting Note) R, Rc NPT Nil N With seal Port size (IN.OUT) Note 1) Compared with standard specifications, its adjusting spring has been only changed for 0.4 MPa.
Description Material ARM1000 ARM2000 134819-30#1 13615 13614 KA00347 16.5 x 13.5 x 1.5 KA00476 JIS B 2401 P7 (Initial setting) Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate: 10 L/min (ANR) 7 8 9 13626-30#1 13625 13624 KA00361 23 x 20 x 1.5 KA00087 JIS B 2401 P8 Valve Valve spring Valve guide Brass, HNBR Stainless steel Polyacetal 10 O-ring NBR Initial set point 11 O-ring NBR
ASS 00 3 AQ ASV Body size Accessory 1 8 Nil None With bracket 1 3 5 6 AK 8 3 B 3 4 1 Port size ASS Applicable series Port size 01 02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Nil N F Rc NPT
10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 13 16 19 20 22 25 108 155 221 1/4, 3/8 3/8, 1/2 1/2, 3/4 3 Series AMP Model Selection Selection Caution Caution 1.
Also, in order to use it under the optimum state, conduct a regular inspection once a half year. 17-6-10
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Model A B C A B C A B C A B C 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 34.5 38 40 33 36.5 38 34 36 37 34 35 36 35 40 44 35.5 40 42 37 40 41.5 38 40 42 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 HAA7 HAA15 HAA22 Maintenance HAA37 Caution 1. Inspect the cooler at least once a week and clean it to prevent it from becoming obstructed. 2.
Handling Precautions . 10 5. Names and functions of parts . 10 6. How to use . 11 7. Specification and how to order . 12 8. Discharge capability . 14 9. Troubleshooting . 16 10. Outer dimensions. 18 2 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.