SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ5-42-11-01T"

It may cause an injury. (10) The table and guide rail are made of special stainless steel, but can rust in an environment where droplets of water adhere to it. (11) Do not dent, scratch or cause other damage to the steel ball rolling surface of the table and rail.

. -11- 9. When the cylinder with cover is mounted vertically, a stroke adjusting unit is installed,or side seal is attached, the cover needs to be removed. See Best Pneumatics Version5-2-P-1352 for the detailed assembly procedure. 10. Release the pressure when performing manual release of the end lock.

No.PS-OMH0003-F PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ISE70 ISE75(H) Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Piping 14 Installation 14 Wiring 15 Setting and Adjustment 17 Initializing 17 Pressure setting 22 Setting of function 24 Maintenance

Allowable Kinetic Energy 11 3-3-1. Allowable Kinetic Energy 11 3-3-2. Mass of Cylinder Movable Parts11 3-3-3. Load mass and Piston Speed 11 4. Wiring 4-1. Connector Wiring Table 12 4-2. Wiring for Counter 12 4-3. Noise countermeasures 12 5. Structure and Measuring Principle 5-1. Structure 13 5-2. Measuring Principle 14 5-3. Relationship Between Pulse and Count 14 6.

Design/Selection 11. Ventilation Provide ventilation when using a valve in a confined area, such as in a closed control panel. For example, install a ventilation opening, etc., in order to prevent pressure from increasing inside of the confined area and to release the heat generated by the valve. 1. Confirm the specifications.

DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 D 8 10.5 13.5 16.5 32

Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) a = 3000 2000 m L1 10 20 30 0 Transfer load m (kg) L2 600 400 L2 (mm) Mer m Rolling Yawing 200 L2 Mer m 10 20 30 0 Transfer load m (kg) 4000 a =1 000 L3 (mm) L3 a = 2000 2000 a = 3000 Mey m a 10 20 30 0 Transfer load m (kg) Refer to page 183 for deflection data. 156 11

/16" 18 68 20.3 23.1 25.9 26.5 107 116 220 230 14.4 50.3 56.2 19.8 41.9 NPT 1/8 NPT 3/8 1/2" 23 46.9 19 18.3 61.8 70.3 26.5 57.3 NPT 1/4 NPT 1/2 28.6 64.8 15/16" 11/16" Reference dimensions of NPT thread after installation. 15-10-3 4 Series ASP Construction w @0 !

DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32

When piping, tighten the regulator with the recommended proper tightening torque (M5: 1.5 to 2Nm, R1/8: 7 to 9Nm) while holding the wrench flats (width 11) of the valve guide for the IN port and holding the hexagonal section of the body for the OUT port. Excessive tightening or holding a part other than those specified can cause damage. 8.

(Refer to page 11 for details.) When compressed air containing ozone (possibly generated from other machinery and equipment present in a plant) enters a pneumatic system, it adversely affects the system's rubber components.

Contact your Sales Representative about SMCs Fitting Cabinet Program Dimensions: 37 1/4 w x 27 9/16 d x 68 11/16 h TB-3VS Vertical Stand Designed for high capacity and reel size flexibility this stand comes with two cross bars.

11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32 40 50 63 2.7-6

Wiring 1) Pass them through the cable (7) in the order of cable ground (4), washer (5), rubber seal (6), and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note) Tighten within the tightening torque of 0.5 Nm 15%. Note) Cable (7) external: 6 to 8 mm 3.

Wiring 1) Passing through the cable (7), cable gland (4), plain washer (5), rubber seal (6) in this order, and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note 1) Tighten within the tightening torque of 0.5 Nm 15%.

Ground 4-7-11 12 Series VT317 How to Use DIN Terminal 1.

Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Pilot pressure (MPa) Caution 1. Lubrication Use turbine oil Class 1 (ISO VG32). 2. Refer to Best Pneumatics Vol. 3 regarding piping, air quality, operating condition and 3 position closed center.

Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions. Design Piping Caution Caution 1. Not suitable for use as a selector valve or a divider valve. The valve can malfunction due to air leakage. 2. Not suitable for vaccum applications. The valve can malfunction due to air leakage. 3. Do not supply air pressure from other ports than 1(P) port.

2 12 For above parts of No. 7 and No. 11, the parts assembly ZA1-OP-1 (10 pcs each) is available. ZH ZU How to Order ZL ZY How to order connector assembly Solenoid valve connector assembly part no.

Specifications Bore size 20 to 63 (3/4" to 2-1/2") Piston speed (no load) 59.1 inch/s (1500 mm/s) Note 1) When operating this cylinder at high speed, a shock absorber must be provided. 11 Series NCY3B Made to Order 3 Please contact SMC for detailed specifications, lead times and prices.