02 AS23 1F-02 AS32 1F AS33 1F AS42 1F AS43 1F Model Metric size 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow) Flow rate /min (ANR) 20 100 180 230 260 390 460 660 790 920 1580 1710 0.3 1.5 2.7 3.5 4 6 7 10 12 14

Electroless nickel plated 6 Brass Stainless steel 304 Lock nut Electroless nickel plated 7 Steel (1) Stainless steel 304 U seal 8 HNBR HNBR Brass parts are electroless nickel plated Polypropylene resin Stainless steel 304, Brass Polypropylene resin Stainless steel 304 Cassette 9 Seal NBR NBR 10 Stopper Stainless steel 304 Stainless steel 304 11 Cushion NBR NBR 12 O-ring NBR NBR 13 O-ring NBR NBR 14

Description Material Note Body A Body B Needle Needle guide Seat ring 1 2 3 4 5 Chromate plated Electroless nickel plated Electroless nickel plated Zinc alloy Brass Brass Brass Brass (1) (2) Meter-out Meter-in Zinc chromate plated Note 4) Lock nut 6 Steel (3) Black zinc chromate plated Handle Bushing Cassette U-packing Seal O-ring O-ring O-ring O-ring Gasket 7 8 9 10 11 12 13 14 15 16 Brass

Position where light turns ON 0.3 to 0.5 mm Position to be secured 12-12-14

SP133X-010E P: RU Pilot Operated Check Valve ASP-X369 Series, XTO Series Intended use: Drop prevention of cylinders and circuit configuration for P.G.Information (Specialized Product) SMC CORPORATION 4-14-1,SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL: http://www.smcworld.com temporary intermediate or emergency stops (Note) Precise intermediate stops are not guaranteed.

pressure using a regulator to be the value in the graphs below. 0 -0.001 -0.002 -0.003 -0.004 -0.005 -0.006 -0.007 -0.008 -0.009 -0.010 -0.011 -0.012 11-CJ2 11-CM2 11-CQ -0.027 13-MXS16 Vacuum pressure (MPa) Vacuum pressure (MPa) -0.028 13-MJP 13-MXS20 -0.029 11-CU -0.030 13-MXS25 -0.031 11-CXS -0.032 1 2 3 4 1 2 3 4 Piping length (m) Piping length (m) Back matter 6 Akihabara UDX 15F, 4-14

AS22IF-U02 AS23IF-U02 AS32IF AS33IF Model 6, 8 4 3.2 4 10 12 8, 10 Metric size 6 6 8 10 12 4 JIS Symbol Tubing O.D. 1 8" 3 16" 1 4" 1 4" 5 16" 5 16" , 3 8" , 5 32" 3 16" 1 4" 5 16" 3 8" 3 8" " 1 2 Inch size 5 32" Flow rate (/min (ANR)) 260 390 660 790 920 1580 180 230 460 1710 Flow Direction Symbols on Body Controlled flow (Free flow) Meter-out type Meter-in type Effective area (mm2) 4 6 10 12 14

Metric size 4 4 6 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C.

Electroless nickel plated 6 Brass Stainless steel 304 Lock nut Electroless nickel plated 7 Steel (1) Stainless steel 304 U seal 8 HNBR HNBR Brass parts are electroless nickel plated Polypropylene resin Stainless steel 304, Brass Polypropylene resin Stainless steel 304 Cassette 9 Seal NBR NBR 10 Stopper Stainless steel 304 Stainless steel 304 11 Cushion NBR NBR 12 O-ring NBR NBR 13 O-ring NBR NBR 14

Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.

Electroless nickel plated 3 Body B Brass Electroless nickel plated 4 Needle Brass Electroless nickel plated 5 Needle guide Brass Electroless nickel plated (1) 6 Seat ring Brass Zinc chromate plated (3) Meter-out Steel (2) 7 Lock nut Black zinc chromate plated Meter-in 8 U seal HNBR 9 O-ring NBR 10 O-ring NBR 11 O-ring NBR 12 01 to 04 type Bushing PBT 13 01 to 04 type O-ring NBR M3 type PVC 14

Dimensions L5 D4 Applicable tubing O.D. d H (Width across flats) A L4 D1 L3 D3 L1 M D2 T L2 [mm] Model T H D1 D2 D3 D4 L1 L2 L3 L4 L5 A M Weight [g] AS221F-G01-06W2D G1/8 12 13.2 14.2 14 7.2 23 31 17.6 39.2 1.2 34.7 17 26 AS221F-G01-08W2D 15.2 25.3 32.4 18.5 28 AS221F-G01-10W2D 18.5 32.1 39.2 21 30 AS221F-G02-06W2D G1/4 17 13.2 18.5 17 7.2 25.2 34.4 20.2 42.8 1.2 36.8 17 46 AS221F-G02-08W2D

Even when setting at a midpoint of the stroke, check the actuation status and make the adjustment in the same manner. 14 Auto Switches Precautions 4 Be sure to read this before handling. Operating Environment Maintenance Warning Warning 1.

Burst pressure Ambient and operating temperature Cv Leak rate Connections Installation Internal volume Mass Select compatible materials of construction for the gas 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45 psig (0.3 MPa) 90 psig (0.6 MPa) 90 psig (0.6 MPa) 180 psig (1.2 MPa) 150 psig (1.05 MPa) 300 psig (2.1 MPa) 300 psig (2.1 MPa) 600 psig (4.1 MPa) 450 psig (3.15 MPa) 900 psig (6.2 MPa) 14

psig (0.034 to 0.7 MPa) Operating Parameters Operating pressure Gas Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45 psig (0.3 MPa) 90 psig (0.6 MPa) 150 psig (1.05 MPa) 300 psig (2.1 MPa) 300 psig (2.1 MPa) 600 psig (4.1 MPa) 450 psig (3.15 MPa) 900 psig (6.2 MPa) 14

2800 5030 4540 7850 7150 12300 11300 15400 14400 20100 18800 25400 23900 31400 29500 49100 46300 70700 66800 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 314 264 491 412 804 691 1260 1100 1960 1650 3120 2800 5030 4540 7850 7150 12300 11300 15400 14400 20100 18800 25400 23900 31400 29500 49100 46300 70700 66800 8 20 10 25 12 32 14

CD1 CD2 CL CP 0.500 0 -.002 0.106 2.28 1.94 NCDP-150-SUS 0.750 0 -.002 0.140 3.10 2.72 NCDP-325-SUS Note: Cotter Pins are included. 7 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, Japan Phone: 03-5207-8271 Fax: 03-5298-5361 URL http://www.smcworld.com 10100 SMC Boulevard Noblesville, IN 46060, U.S.A.

I Wear ring Plastic I C 1 A040-07-305 W Cushion packing A NSR f1j Cushion packing B NBR MC-20 CM-050-16-128 CM-063-16-129 C 1 AQ50-07 -306 C 1 A063-07-307 MC-25 MC-20 I MC-25 @) Gasket for cushion valve NSR CK40-1697 @I Gasket for speed controller NBR iii) Detecting rod packing NSR CK40-1697 DYR5K 14(1.

operated handle CKZT A000 25 C S X2797 Clamp arm Arm mounting position Center C Right R Left L Mounted clamp arm 1 Power Clamp Cylinder CKZT -X2797 -X2798 Cylinder Specifications Bore size 25 32 Action Double acting Fluid Air Proof pressure 174 psi [1.2 MPa] Max. operating pressure 116 psi [0.8 MPa] 73 psi [0.5 MPa] Min. operating pressure 44 psi [0.3 MPa] Ambient and fluid temperatures 14

Note 2) (Max EB) Note 3) 5 9 2.4 25 (Max EA) 1.4 32 5.5 (mm) Size EA EB HA 6.6 CRJU05 CRJU1 5.6 33.8 6.5 3.1 5.6 35.8 7.5 (mm) Size Rotating angle 90 A BA BB BC BD BE BF BG BH BI CA CB D DD J JA JB JC JD H N Q S SD UU W 21.5 32.4 43 CRJB05 19.5 30 9.5 11 6.5 3.5 17.1 20 7 5.5 5g6 10h9 M4 x 0.7 5.8 3.5 M4 x 0.7 5 14.5 12.5 13.5 3.4 28 4.5 180 27 43.4 54 90 24 37.4 48 CRJB 1 23.5 35 12.5 14