Low clamping torque Specifications Gap (approx. 0.5mm) Applicable tube material Polyurethane Applicable tube dia. 2/1.2 1MPa Max. operating pressure (at 20C) 4. Insert the sleeve slowly. Make sure not to allow any gap between the sleeve end side and the body end side. (Please refer to the illustration below.)

200 to 230 VAC) 1000 1000 Ambient 40C Ambient 32C Ambient 25C Ambient 40C 800 800 600 600 Ambient 32C 400 400 Ambient 5C Ambient 20C Ambient 25C Ambient 5C Ambient 20C 200 200 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 [50 Hz] Circulating fluid temperature [C] [60 Hz] Circulating fluid temperature [C] Pump Capacity 012 018 024 A W 012 018 A W HRS -20 (Single-phase 200 to 230

Correction Factor by Ambient Temperature Mounting Caution (Example) Inlet air temperature: 100C, Ambient temperature: 20C, Amount of air: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAA22-14 Outlet Air Temperature at Above Conditions Use outlet air temperature of 38.5C from outlet air temperature table. At this time correction factor line becomes . 1.

: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control mode by inverter.

temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200/400 VAC, u Piping length: Shortest 6 When circulating uid outlet port pressure = 0.5 MPa. 7 Fluid ow rate to maintain the cooling capacity and to keep the circulating uid discharge pressure to 0.5 MPa or less.

: 32C, w Circulating fluid: Tap water, e Circulating uid temperature: 20C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 460 VAC, u Piping length: Shortest 6 Fluid ow rate to maintain the cooling capacity.

Note 5) The capacity at the thermo-chiller outlet when the circulating uid temperature is 20C. Note 6) Required ow rate for cooling capacity or maintaining the temperature stability. The specication of the cooling capacity and the temperature stability may not be satised if the ow rate is lower than the rated ow.

Note 4) The capacity at the circulating fluid outlet when the circulating fluid temperature is 68F (20C). Pump capacity at 60 Hz indicates the maximum capacity of the HRWlll-HS (pump inverter type). Note 5) Applicable to the HRWlll-HS (pump inverter type) only. Note 6) Minimum volume required for operating only the Thermo-chiller.

Port size Thread type Symbol Bore Size Nil N F Rc NPT G 1 5 10 20 30 3 50 60 75 100 01 1/8 02 1/4 04 1/2 03 3/8 Standard Specifications/Single Style (Standard Dew Point 20C [4F]) Standard dew point 20C (4F) Model IDG1 IDG5 IDG10 IDG20 IDG30 IDG50 IDG60 IDG75 IDG100 IDG3 IDG1 Fluid Compressed air Range of operating conditions Standard performance conditions Standard performance Inlet air

(mm) 2 x 1.2 Fluid Air, Water Max. operating pressure (at 20C) 0.8MPa Burst prssure Refer to pressure characteristics curve.

conductance dm3/(sbar) 1/4 3/8 1/2 3/4 1 1 1 10 3,600 4,800 6,700 8,100 16,900 38,500 47,500 60,800 AS420-02 AS420-03 AS420-04 AS500-06 AS600-10 AS800-12 AS900-14 AS900-20 2,500 5,000 6,600 6.9 13.9 18.3 28.1 42 98 144 161 0.34 0.33 0.32 0.36 0.7 1.4 3.3 3.3 13.3 18.6 22.5 47 107 132 169 10,100 15,100 35,400 52,000 57,800 0.45 0.25 1 4 1 2 2 Note) Flow rate values are measured at 0.5 MPa and 20C

AS221FE-01 AS231FE-01 AS221FE-02 AS231FE-02 AS321FE AS331FE AS421FE AS431FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D. 4 6 Metric size 4 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C

Note 3) Do not cut the tube. 1 Use the product in an operating environment where humidity is as low as possible. 2 The value at which the moisture control tube is bent or flattened at 20C. Be careful not to bend or flatten the tube and the inner sleeve even if the value is more than the minimum bending radius. 2 Inner sleeve R How to Order IDK 02 100 Moisture control tube O.D.

Note) Not applicable with the cases of standard dew point 20C (Nil), 15C (symbol H).

(Example) Inlet air temperature: 100C, Cooling water temperature: 20C, Cooling water flow: 17 l/min Air flow: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAW22-14 Outlet air temperature at above conditions Use outlet air temperature of 37C from outlet air temperature table. At this time correction factor line becomes .

FGF FGH FGH [Test conditions] Fluid: water / Test dust: ACFTD / Flow rate: 35 L/min Dust concentration: 10 mg/L / Temperature: 20C Element: EJ801S Schematic diagram of filtration efficiency data measuring circuit FQ1 EJ-2 m FN 100 99 Dust feeder Initial filtration efficiency (%) EJ-4 m EB ES Tank Flow meter EJ-6 m Differential pressure gauge EJ-13 m 95 Pressure gauge Downstream side sampling

(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 Flow rate (l/min (ANR)) 460 790 920 1580 100 180 230 390 Controlled (free) flow 7 12 14 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.

foot for fixing) Weight Accessories Power cable, Foot for fixing CE marking, UL (NRTL) standards CE marking, UL (NRTL) standards, Safety standard for medical equipment (IEC 60601-1) Safety standards Note 1) Conditions: Set temperature 77F (25C), Ambient temperature 77F (25C), Circulating flow rate 0.79 gpm (3 L/min) Note 2) Conditions: Set temperature 77F (25C), Ambient temperature 68F (20C

(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) Accessory (Option)/Replacement Parts Applicable model ID20 ID30 ID40 ID60 6604113 6604113 660651 660651 ID-200S ID-300S ID-400S ID-600S ID-200Z ID-300Z ID-400Z ID-600Z ID-DPM8 Bracket Adsorbent set Note) Adsorbent set (for low dew point) Note) Indicator set Note) Adsorbent and adsorption tube filter for one air dryer (two adsorption

Air consumption Note 3) 18 L/min (ANR) or less (SUP = 0.5 MPa) Note 1) Specification values are given at normal temperature (20C). Note 2) Characteristics relating to accuracy differ depending on combination with other constituent loop equipment, such as positioners and actuators. Note 3) Air consumption is due to exhaust from nozzle. And (ANR) indicates JIS B0120 standard air.