SMC Corporation of America
Elite Part Number Search
Search Results "LPV22-6GZ-T6A-10"

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (relief type), Port

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (vacuum type), Port

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (vacuum type), Port

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (vacuum type), Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber bumper at both ends, Specification: Clean series (relief type sliding

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber bumper at

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber bumper at

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: With speed adjustment function, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.1~0.7, Auto Switches: M9B, Lead

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Non-use of Copper-zinc Material, Operating Pressure(MPa): 0.05 to 0.7,

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Specification: Clean Series (vacuum type), Port thread type:

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Specification: Clean Series (vacuum type), Port thread type:

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Specification: Clean Series (vacuum type), Port thread type:

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Specification: Clean Series (relief type), Port thread type:

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Specification: Clean Series (relief type), Port thread type:

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion,

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Port thread

Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.3~0.7, Cushion: None, Specification: Without hose nipple, Auto

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.2~0.7, Cushion: None, Specification: -, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.2~0.7, Cushion: None, Specification: Without hose nipple, Auto

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Specification: Without hose nipple, Auto