This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product, and replaced bySQ1241D-5LO1-L4-M
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Body: T (Body Ported), Valve Specification: Non (Standard), Port Size: 02 (1/4), Voltage: 5 (24 VDC), Electrical Entry: DL (DIN Terminal w/ Indicator Light), Surge Voltage Suppressor: S (w/ Surge Voltage Suppressor), Manual Override: M [Locking Type (Tool Required)], Thread: N (NPT), CE-Compliant: Q (CE-Compliant)
Body: T (Body Ported), Valve Specification: Non (Standard), Port Size: 03 (3/8), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal), Surge Voltage Suppressor: S (w/ Surge Voltage Suppressor), Manual Override: M [Locking Type (Tool Required)], Thread: N (NPT), CE-Compliant: Q (CE-Compliant)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X143 (Piping