Bowl assembly for AL40, 50, 60-D Semi-standard symbol 6 3 36 Semi-standard: (Standard) Semi-standard: 3 Piping port thread ty pe Piping port thread ty pe (7) Part No. (7) Part No. Rc Rc C4SL-D C4SL-3-D G G NPT C4SL-3(Z)-D NPT C4SL(-Z)-D Appearance and part No. Semi-standard: 36 Semi-standard: 6 Piping port thread ty pe Piping port thread ty pe (7) Part No. (7) Part No.
Hz 50/60 Hz 50/60 Hz Maximum micro power cut 10ms 10ms 5ms 10ms 5ms Maximum inrush current 0.7A 1.5A 0.7A 1.5A 7A 0.7A 1.5A 7A Maximum power 3W 4W 3W 8W 6W consumption ANALOGUE INPUT CHARACTERISTICS AC INPUT CHARACTERISTICS 10 6 inputs from I01 to I06 Input voltage 100-240 VAC + 10% 15%, 20 8 inputs from I01 to I08 50-60 Hz Measurement range 0-255 Input impedance >or = 800 kOhms Resolution
87 60 112 112 17-5-55 14 Series LVD Fitting Assembly Procedure Assemble fittings following the procedure shown below.
All types are equipped with surge voltage suppressor. 17-2-10 5 Series VCA Direct Operated 2 Port Solenoid Valve For Air Standard Specifications Valve construction Direct operated poppet Fluid Air, Inert gas, Low vacuum (133 Paabs) Withstand pressure (MPa) 2.0 Body material Al Seal material HNBR Valve specifications Ambient temperature (C) 20 to 60 Fluid temperature (C) 10 to 60 (No freezing
power (VA) 50/60 Hz VXA Holding VCS2: 10/8, VCS3: 15/13, VCS4: 19/16 Note 1) For low pressure steam at a temperature of 120C or less, use FKM for the seal material.
Foot bracket VZS 5 1 3 VFS 22.2 Die cast hole For manifold gasket positioning PE port VS VS7 L plug connector (L): VQZ112 wLwC3, C4, C6, M5 0 1 M plug connector (M): VQZ112 wMwC3, C4, C6, M5 0 1 Cover diameter 1.5 Cross section 0.23mm2 34 <39> 300 (Lead wire length) 76 (Metal seal) <77> 73.5 (Rubber seal) <74.5> 300 82 (Metal seal) <83> 54 <55> (Lead wire length) 80 (Rubber seal) <81> 60
Note 8) For details about wiring, refer to the Operation Manual that can be downloaded from SMC website (http://www.smcworld.com). 1.0 Operating pressure [MPa] PF2D 504/520 0.5 PF2D 540 Made to Order 20 40 60 80 100 0 90 LQ1 series fluoropolymer fittings mounting type is also available. Refer to page 392.
-X Operating temperature range (C) 5 to 60 The shock absorber service life is different from that of the MY1H cylinder depending on operating conditions.
80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate L/min (ANR) Flow rate L/min (ANR) SRP1101-01 Conditions/Inlet pressure: 0.5 MPa SRP1-01 Conditions/Inlet pressure: 0.7 MPa 0.25 0.50 0.20 0.40 Outlet pressure MPa Outlet pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate L/min (ANR) Flow rate L/min (ANR) Pressure
DIN connector DIN connector with light A surge voltage suppressor is integrated inside the coil as a standard feature. 2 Made to Order 2(OUT) 1(IN) Made to order specifications (For details, refer to page 235) 22.0 MPa 2 Port Air Operated Valve Specifications Response Time 60 VCH42 (N.O.) VCH41 (N.C.)
4 3 Port Solenoid Valve Direct Operated Poppet Type Series VKF300 How to Order Valves Electrical entry G: Grommet (Lead wire length: 300 mm) Rated voltage D: DIN terminal DO: DIN terminal H: Grommet (Lead wire length: 600 mm) 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 4 50 60 5 6 7 50 60 9 Option Thread
0.8 thread depth 10 2 x 2 x M5 x 0.8 (Hexagon socket head cap plug) 2 x M5 x 0.8 Cylinder port 2 x 2 x M5 x 0.8 Thread depth 10 4 x 4.3 through 4 x 8 counterbore depth 4.5 2 x RB0805-X552 Shock absorber 2 x 2 x 5H7 depth 6 +0.012 0 CX2 CXW (mm) CXT L P Q S SS Z ZZ F Model CXWM16-50 CXWM16-75 CXWM16-100 CXWM16-125 CXWM16-150 CXWM16-175 CXWM16-200 35 63 30 164 52 100 152 188 CXSJ 32.5 88 60
Hz 00 01 Without sub-plate Rc 1/8 (6A) Accessory 2 200 VAC, 50/60 Hz Without sub-plate (For manifold) 4 Indicator light (DC is possible only for DL.)
Hz) (l/min) Port size Wetted parts material Power supply Breaker capacity (A) Rated current (A) Alarm Communications 5/5 6/6 15/22 18/23 3/4 5/6 9/10 13/14 6/7 13/14 Rc 1/2 Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass 3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 20 14 30 23 30 20 25 60 46 Refer to page 94.
(50 Hz), 5.0VA (60 Hz) Inrush Energized Current consumption AC AC50 AC40 AC25 AC30 AC20 3.4VA (2.1W) 50 Hz, 2.3VA (1.5W) 60 Hz VHS20 VHS30 VHS40 VHS50 Current consumption DC 1.8W Electric entry Type D DIN Terminal, M12 connector Optional specification Indicator light/Surge voltage suppressor
Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz S L Small flow Large flow Control valve 0 None Flow control valve (With pressure compensation) Throttle valve Timid flow control valve (Only CCVS series) 1 Semi-standard 2 Combined valve 3 0 1 2 3 None Stop valve, Skip valve Stop valve Skip valve For the one without combined valve (0), solenoid valve
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) Specications Model HRSH090-Al-20-l HRSH090-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) (GWP1975) Refrigerant charge kg 1.32 Control method PID control Ambient temperature/humidity Note 1), 9) C/% 5 to 45/30 to 70% Circulating uid Note 2) Tap water, 15% Ethylene
VK300 Series How to Order Note) CE-compliant: For DIN terminal only [Option] Electrical entry D: DIN terminal DO: DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) Rated voltage Valve option Rated voltage Nil V Y W E CE-compliant 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240
Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.
Hz) Class B NBR 200 VAC (50/60 Hz) FKM Stainless steel VDW 110 VAC (50/60 Hz) EPDM 220 VAC (50/60 Hz) VQ FKM 24 VDC Note) The armature assembly is a corrosion resistant construction. 12 VDC LVM 6 VDC 5 VDC VCA Nil Thread type 3 VDC Rc Please consult with SMC regarding other voltages.