SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-M5-DY"

Piping: ø6 One-touch Fitting, Elbow Type, Output: NPN Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: None, Made to Order: -

Piping: ø4, ø5/32" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: None, Made to Order: -

Piping: ø4, ø5/32" One-touch Fitting, Elbow Type, Output: PNP Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: None, Made to Order: -

Piping: ø1/4" One-touch Fitting, Elbow Type, Output: PNP Open Collector 1 Output+Analog Voltage Output, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: None, Made to Order: -

The EX510 series makes it possible to connect more valves and sensors than with conventional units.  With the introduction of the EX510 series, only a power supply cable to the GW unit is required, resulting in wire-savings.  Setting the address for the SI unit, output unit and input unit is no longer required, only the address for the GW unit needs to be set.  The volume ratio of the EX510

The EX510 series makes it possible to connect more valves and sensors than with conventional units.  With the introduction of the EX510 series, only a power supply cable to the GW unit is required, resulting in wire-savings.  Setting the address for the SI unit, output unit and input unit is no longer required, only the address for the GW unit needs to be set.  The volume ratio of the EX510

Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: w/o Operation Manual, w/o Calibration Certificate

Air leakage. -20No.PF-OMO0010-C Specification Specifications Specifications of body Model PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Applicable fluid Air and N2 Fluid temperature 0 to 50 C (no condensation or freezing) Flow Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 L/min L/min L/min L/min L/min Pressure Rated pressure range -50 kPa to 0.5 MPa -50 kPa to 0.75 MPa Proof pressure

mode [d_1] Display instantaneous flow Common Unit selection function [U_1] L/min Indicator LED Indicates the reference condition selected.

industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: (1 ) JIS B 8433-1993: 2) 1. 2. 3. 1. 2. 3. 4. 4/12 FGX-OM-L009-B 1 1.5 3) 3)1 1 () 5/12 FGX-OM-L009-B FGESL Series FGESL O (P) 0.02MPa () FGE S L A:179mm FGE S V V (P11) L B:419mm FGE S L C:669mm V (V )V 50mm O .

Start flag 0: no send Numerical data input 16 1: send 1 Step data No 0 to 63 Data writting 17 Operation Note) 1 1: Absolute 2: Relative 18 H 19 L Speed 2 0 to 65500 mm/s 20 3 21 2 Position 4 +/-2147483647 0.01mm 22 1 23 0 24 H ID1 Numerical 25 L Acceleration 2 0 to 65500 mm/s2 data input 26 H 27 L Deceleration 2 0 to 65500 mm/s2 Data writting 28 Pushing force 1 0 to 30 10% 29 Threshold 1

bit 0,1 3 RESET bit 0,1 15 4 SETUP bit 0,1 5 bit 0 6 bit 0 7 bit 0 LECP6 LECA6 37 - Bit/Byte / Q_Address ID No. 0 1 16 1 063 1ABS 17 1 2INC() 18 H 2 065500 mm/s 19 L 20 3 21 2 4 2147483647 0.01mm 22 1 23 0 ID1 24 H 2 065500 mm/s2 25 L 26 H 2 065500 mm/s2 27 L 28 1 030 10% 29 1 030 10% 30 1 0255 mm/s 31 1 030 10% 32 H 2 065500 0.01mm 33 L ID2 3453 ID1 ID3 5473 ID1 ID4 7493 ID1

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket:

Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket:

: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket