max Model CYV15 1 CYV32 5 (Nm) M1 M2 Model CYV15 CYV32 M1 0.3 3 M2 0.6 4 M3 0.3 3 m m Static Moment Moment generated by the work piece weight even when the cylinder is stopped Pitch moment M1 = m x g x (L + B) x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYV15 CYV32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m: Load mass
max Model CYV15 1 CYV32 5 (Nm) M1 M2 Model CYV15 CYV32 M1 0.3 3 M2 0.6 4 M3 0.3 3 m m Static Moment Moment generated by the work piece weight even when the cylinder is stopped Pitch moment M1 = m x g x (L + B) x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYV15 CYV32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m: Load mass
Point of application L (mm) Point of application L (mm) Work piece transfer speed Distance of work piece drop A V (m/min) H (m/min) Coefficient of friction between the work piece and conveyor Gravitational acceleration g (m/s2) Transfer speed V Point of application L Procedure2 Confirmation of impact 1.
(Panel mounting hole: See Dimensions.) 2 r o t c e n n o C h c n I c i r t e M 8 / 1 1 0 P M D K 2 . 3 3 2 P M D K e u l B 2 3 / 5 3 0 P M D K 4 4 0 P M D K r o t c e n n o C g u l P d e R 4 / 1 7 0 P M D K 6 6 0 P M D K 6 1 / 5 9 0 P M D K 8 8 0 P M D K 8 / 1 1 0 P M D K 2 . 3 3 2 P M D K r o t c e n n o c t e k c o S ) g n i k c a p h t i W ( e u l B 2 3 / 5 3 0 P M D K 4 4
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 M5 x 0.8 M3 x 0.5 10.5 16 M6 x 1.0 M4 x 0.7 11.5 20 M8 x 1.25 M5 x 0.8 13.5 25 M10 x 1.25 M6 x 1.0 16.5 30, 40 M14 x 1.5 M8 x 1.25 22.5 Clevis pin d Dd9 m m l t L t Applicable bore size (mm) Applicable snap ring Part no.
Lead wire length symbols: 0.5 m Nil 3 m L 5 m Z Solid state switches marked "" are produced upon receipt of order.
F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced
Nil (Example) M9NWV 1 m M (Example) M9NWVM 3 m L (Example) M9NWVL 5 m L (Example) M9NWVZ 536 Pin Clamp Cylinder Plate Cylinder Type Magnetic Field Resistant Auto Switch/Small Auto Switch Mounting C(L)KU32 Series Basic Specifications LOW type LOW type with lock Model C(L)KU32 Action Double acting Bore size [mm] Equivalent to 32 Cylinder stroke/Clamp stroke [mm] 12.5 (Without workpiece)/10
Temperature specifications Symbol Nil M9N (L) M9P (L) M9B (L) A90 (L) A93 (L) M9// Symbol Nil H0 Temperature range 5 to 60C 5 to 150C Without auto switch (without built-in magnet) Remarks Auto switch D-M9N (L) D-M9P (L) D-M9B (L) D-A90 (L) D-A93 (L) Solid state switch 6. No. of auto switches/Detecting position Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.
Free mount type Shaft type Double vane Double shaft with single flat (size 10 to 30) Long shaft key, Short shaft with single flat (size 40) W Electrical entry/Lead wire length Grommet/Lead wire: 0.5 m Grommet/Lead wire: 3 m Connector/ Lead wire: 0.5 m Connector/ Lead wire: 3 m Connector/Without lead wire Nil L C CL CN Pattern Vane type Standard Simple Specials/Made to Order S D Single vane
(M) -45D (M) x 110L 110 135 x 135L -50D (M) -50D (M) x 115L 115 140 x 140L -75D (M) -75D (M) x 140L 140 165 x 165L -100D (M) -100D (M) CHQWB100-10D (M) x 165L 165 190 x 190L CHQWB40-5D (M) CQ-M5 x 75L CQ-M10 x 105L 75 105 -15D (M) -10D (M) x 80L 80 x 110L 110 -20D (M) -15D (M) x 85L 85 x 115L 115 -25D (M) -20D (M) x 90L 90 x 120L 120 -30D (M) -25D (M) x 95L 95 x 125L 125 -35D (M) -30D (M
(MPa) FGE FGG FGA FGC FGF Flow rate (L/min) Flow rate (L/min) FGH FGH FGH200-06 {Rc3/4} FGH200-10 {Rc1} FQ1 Pressure drop (MPa) Pressure drop (MPa) FN EB ES Flow rate (L/min) Flow rate (L/min) FGH300 Series FGH300-03 {Rc3/8} FGH300-04 {Rc1/2} X20 (0.2 m) X40 (0.4 m) Pressure drop (MPa) Pressure drop (MPa) Flow rate (L/min) Flow rate (L/min) FGH300-06 {Rc3/4} FGH300-10 {Rc1} Pressure drop
Horizontal (without switch) Horizontal (with switch) 30 30 10 10 100 100 Load weight m (kg) Load weight m (kg) 80 5 5 80 63 63 50 50 40 40 1 1 0.5 0.5 32 32 25 25 20 20 0.1 0.1 10 100 10 100 Eccentric distance + Stroke L (mm) Eccentric distance + Stroke L (mm) m l S l: Eccentric distance (mm) S: Stroke (mm) L Allowable kinetic energy Pneumatic Circuits Extension locking, Without cushion Retraction
(Example) Nil Lead wire length 0.5 m 3 m L 5 m Z None N Applicable for the connector type (D-C) only. Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-A73(C)(H)/A80C Solid state switch: Manufactured upon receipt of order as standard.
(2-color indicator) 2-wire 12 V 24 V Grommet Yes Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 2-wire 12 V 3-wire (NPN equivalent) Reed auto switch Z76 IC circuit 5 V Yes Grommet 100 V Z73 IC circuit Relay, PLC 24 V 12 V 2-wire Z80 100 V or less Lead wire length symbols: 0.5 m Nil (Example) Y7BW 3 m L (Example) Y7BWL 5 m Z (Example) Y7BWZ Solid state auto switches marked
L plug connector (L) M plug connector (M) 28.9 (For AC) 27.6 (For DC) R P R P 15.6 39.1 (For DC) 45.6 (For AC) 37.2 (Light/Surge voltage suppressor) (Light/Surge voltage suppressor) 23.6 Other dimensions are same as grommet type.
30 50 Lead 8: LEKFS32(L/R)EB Lead 8: LEKFS32(L/R)EB 40 Work load: W [kg] Work load: W [kg] 20 30 Lead 16: LEKFS32(L/R)EA Lead 16: LEKFS32(L/R)EA 20 10 Lead 24: LEKFS32(L/R)EH Lead 24: LEKFS32(L/R)EH 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 Speed: V [mm/s] Speed: V [mm/s] Vertical LEKFS40(L/R)/Ball Screw Drive Horizontal 70 60 30 Lead 10: LEKFS40(L/R)EB Lead 10: LEKFS40
L L plug connector, Without connector, With indicator light and surge voltage suppressor LO Consult SMC for other voltages. M plug connector, With lead wire and light and surge voltage suppresser. M M plug connector, Without connector, With indicator light and surge voltage suppressor MO G Grommet L plug connector Note) Grommet: No latching, AC and large flow capacity.
5V, 3V DC Grommet L plug connector M plug connector : Non-locking push style D: Push-locking slotted style G: 300mm lead wire L: 300mm lead wire M: 300mm lead wire MN: Without lead wire L P E: Push-locking lever style B: Locking slotted style H: 600mm lead wire LN: Without lead wire LO: Without connector MO: Without connector L P 1 0 LN or MN option includes 2 sockets.