SMC Corporation of America
Elite Part Number Search
Search Results "HRW008-H-CNZ"

Variations include, energized open (N.C) and energized closed (N.O) valve, solenoid coil (class B, class H), brass/BC6 or stainless steel body material and NBR, FPM, EPR seal materials., Pilot Op 2 Port Solenoid Valve (N.C.), 2 PORT VALVE, 1360 lb

Application can be matched by simply choosing body materials (brass, stainless steel), seal materials (NBR, EPR, FPM, PTFE) and the solenoid coil (class B, class H).

By using H-NBR seal material for the main valve and seals, Ozone resistance has been improved. Side, top and bottom port/pipe directions are available to allow flexible installation. The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted., VALVE, SOL, 4/5 PORT SOLENOID VALVE, 0.5 lb

By using H-NBR seal material for the main valve and seals, Ozone resistance has been improved. Side, top and bottom port/pipe directions are available to allow flexible installation. The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted., VALVE, SOL, 4/5 PORT SOLENOID VALVE, 0.5 lb

By using H-NBR seal material for the main valve and seals, Ozone resistance has been improved. Side, top and bottom port/pipe directions are available to allow flexible installation. The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted., VALVE, SOL, 4/5 PORT SOLENOID VALVE, 100 lb

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

Application can be matched by simply choosing body materials (brass, stainless steel), seal materials (NBR, EPR, FPM, PTFE) and the solenoid coil (class B, class H).

H Half duplex Communication system that sends and receives data in one direction at a time. I Idle Expression for PLC operation state. For details, Refer to manuals of each PLC maker. Depending on which PLC is used; the idle state might not be available. IP address A 32 bit digit sequence which is assigned to identify devices which are connected to the network.

H Half duplex Communication system that sends and receives data in one direction at a time. I Idle Expression for PLC operation state. For details, Refer to the manuals of each PLC maker. Depending on which PLC is used; the idle state might not be available. IP address A 32 bit digit sequence which is assigned to identify devices which are connected to the network.

H Handheld Terminal (H.T.) Abbreviation of handheld terminal. It is possible to monitor the input/output data and diagnostic data and set parameters. I Idle Idle refers to the SI unit operation mode, which is either in the default, pre-operational or safe operational modes. For details, Refer to manuals of each PLC maker. M Manifold A form consisting of multiple components.

H Half duplex Communication system that sends and receives data in one direction at a time. I IP address A 32 bit digit sequence which is assigned to identify devices which are connected to the network. MAC address A unique number inherent to all devices which are connected to POWERLINK. M Manifold A form consisting of multiple components.

Specifications Table 5-1 EX260-FPS1specifications Item Description General Dimensions (W x L x H) mm 28.2 x 102.4 x 78.0 Weight 200 g or less Housing material PBT Rated voltage 24 VDC Supply interruption for no loss of function 1 ms and less Protection class IP67 (when fully installed or fitted with protective cover) (complies with IEC 60529) 10 Mega ohms or more between FE and other terminals

Red B Line 4 Red 4 White CAN H 5 Blue CAN L 5 Blue Preparation Connection surface Blue Blue Yellow Black Stripper for cable sheath (recommended) WIREFOX-D 11 (Phoenix Contact No.1212160) Stripper for conductor sheath (recommended) WIREFOX 2,5 (Phoenix Contact No.1212368) Cutters for cutting shield (recommended) MICROFOX-SP (Phoenix Contact No.1212488) White Red Red White Green Grey Grey Product

Function selection mode H Hysteresis Difference between the ON and OFF points of switch output. Hysteresis mode Refer to the "List of output modes" on page 41. I Insulation resistance Insulation resistance of the product. The resistance between the electrical circuit and the case.

(full span/full scale) H Hysteresis Difference between the points at which the Pressure switch is turned on and off. I Indication accuracy Shows the deviation between displayed pressure value and the true pressure. Indication light The light that turns on when the switch output is on. Indication resolution How fine the rated pressure range can be segmented.