SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B100-100DMZ-W-A93"

A96 A93 A90 5 V Yes IC circuit Individual -X Grommet No 2-wire 100 V Relay, PLC 24V 12 V IC circuit 100 V or less Solid state auto switches marked are produced upon receipt of order.

Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with a symbol are produced upon receipt of order.

IC circuit A96 A96V 5 V Yes 24 V Grommet A93V2 A93 A90 100 V Relay, PLC 2-wire 12 V A90V No IC circuit 100 V or less 1Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. 21 m type lead wire is only applicable to D-A93.

Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.

However, please contact SMC for water resistant products of 12 and 16. *2: The D-P3DWA is mountable on bore size 25 to 100. *3:1 m type lead wire is only applicable to the D-A93. *: Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ *:Solid state auto switches marked with are produced upon receipt of order.

NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) Reed switch Solid state switch A96V A96 5 V IC Yes Yes Grommet A93 M9N M9P M9B F9N F9P F9B F9NW F9PW F9BW F9BA A93V F9NV F9PV F9BV F9NWV F9PWV F9BWV 100 V 24 V 12 V Relay, PLC 5 V, 12 V IC 12 V 5 V, 12 V IC Relay, PLC 24 V Grommet 12 V Diagnostic indication (2-color) 5 V, 12 V IC

Auto switch and the connector Parallel seal type slit valve Symbol Auto switch Connector Nil A Lead wire: 0.5m Multiple connector(AMP) *C016 30D006 100 12 made by AMP is recommended for the connector (female type) C D-A93 (2pcs) D-sub connector *CDE-9SF05 made by HIROSE ELECTRIC CO.,LTD. is recommended for the connector (female type). F 5 - 3.

Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.

Lead wire length (m) Load voltage 5 (Z) Applicable load Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 1 (M) 3 (L) AC DC 12 V In-line A93 M9N M9B Reed auto switch 24 V 2-wire 100 V 12 V Relay, PLC Grommet Yes 3-wire (NPN) Solid state auto switch 24 V Relay, PLC Grommet Yes 12 V 2-wire Lead wire length symbols

function Wiring (output) Type Electrical entry 0.5 (Nil) 3 (L) 5 (Z) DC AC 3-wire (NPN) 3-wire (PNP) 2-wire M9N M9P M9B A90 A93 5 V, 12 V Solid state switch Relay, PLC 24 V Grommet Yes 12 V 5 V, 12 V 12 V 100 V or less 100 V IC circuit no Yes Relay, PLC 24 V 2-wire Reed switch Grommet 161

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ROD SIDE BOSS, ACTUATOR, CQ2 COMPACT CYLINDER, SC, 100MM CQ2 OTHERS (COMBO), 6.11782 lb

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 50mm, Port Thread Type: TN (NPT 32-63 Bore), Stroke: 100mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

The MU plate cylinder, with its elliptical design, provides a low profile while maintaining force output. The MU cylinder can eliminate the need for higher operating pressures that may be required for typical flat cylinders. The oval piston shape also provides an intrinsic non-rotating function without having to use a rod with flats, offering increased bearing and seal life.Single acting

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: None, Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)