Do the same for release (push and rotate for 90 degrees). Tighten the piping using the correct torque shown below.
M5 x 0.8 (Finger opening port) D3 O 20S 13 3 23 7 M5 x 0.8 (Finger closing port) 4 2 MHY2-10D2 Opening/Closing direction through-hole type 4-3.4 (Hole for mounting attachment) 6 0.005 0.025 3 6 12 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-11 11 Series MHY2 Dimensions MHY2
Do not scratch or gouge the escapement by dropping or bumping it when mounting. Even a slight deformation can cause inaccuracy or malfunction. 2. Please observe the specified torque limits when tightening screws to mount the attachment.
Lubrication of non-lube type cylinder Do not apply lubrication when controlling for low speed or controlled output. If lubrication is applied, there may be changes in operating resistance due to factors such as the viscosity and surface tension of the oil. Also, use a metal seal type when using solenoid valves for cylinder actuation.
M5 x 0.8 (Finger opening port) D3 O 20S 13 3 23 7 M5 x 0.8 (Finger closing port) 4 2 MHY2-10D2 Opening/Closing direction through-hole type 4-3.4 (Hole for mounting attachment) 6 0.005 0.025 3 6 12 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-11 11 Series MHY2 Dimensions MHY2
;(E a Slip exceeding retaining force may damage brake shoe, which could lead to reduced relaining force, resulting in its shorter lile a Cylinder loading should be within 35'/" of holding force when the brake is used for droo oroteclion, a Do not apply any impact when you load the cylinder in the locked position.
Caution Do not disconnect the USB cable during Teaching. If disconnected, the actuator will stop suddenly and the servo will be turned OFF.
Do not load the Card Motor with continuous or higher thrust than allowed for a prolonged time. When a pushing operation step data is selected, the pushing force is continuously generated from [Operation Start] until [Operation End (Stop)] is pressed.
Operating Environment Warning (1) Do not operate under the conditions listed below due to a risk of malfunction. In locations having corrosive gases, organic solvents, and chemical solutions, or in locations in which these elements are likely to adhere to the equipment. In locations in which salt water, water, or water vapor could come in contact with the equipment.
Connect End Plate and tighten removed screws by specified tightening torque. (0.6 Nm) Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Note 1. The power supply should be off while setting the switches. 2.
Red flashing SI unit has detected the transmission rate, but is not addressed by the DP master OFF Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.
Do not connect the terminating resistor outside, when the setting switch for the terminating resistor is ON. (4)How to connect.
Caution Mounting 1) Do not subject the gauge to shocks, such as dropping during transportation and mounting, as this can cause loss of indication accuracy. 2) Do not use this gauge in a location with high temperature and humidity, as this may cause faulty operation. 3) When mounting the pressure gauge, be certain to use a wrench on the square wrench flats to screw it into place.
Do not use valves in such environments where corrosive gases, chemicals, or brine or water or steam is airborne, or where valves can be directly exposed to any of those. 2. Do not use in an explosive environment. 3. Do not use in locations influenced by vibrations or impacts. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5.
Do not exceed the screw-in torque of 3.5 Nm when installing piping. Exceeding this value may cause malfunctioning of the sensor. 4. The minimum bending radius of the cable is 50 mm. 5. Do not use pressure sensors with corrosive and/or inflammable gases or liquids. 1. Incorrect wiring can damage the switch and cause a malfunction or erroneous switch output.
Do not use with pressure or temperature beyond the specification range.
;(E a Slip exceeding retaining force may damage brake shoe, which could lead to reduced relaining force, resulting in its shorter lile a Cylinder loading should be within 35'/" of holding force when the brake is used for droo oroteclion, a Do not apply any impact when you load the cylinder in the locked position.
Do not use these for pneumatic operations because they will lead to oil leaks. Air-hydro cylinder: CA1HCQ2HCS1HCM2HCG1H(up to 63) HC03-X1x Air-hydro rotary actuator: CRA1H2.
For the auto switch mounting rail, do not remove the pre-equipped rail. Since the mounting thread is drilled through inside a the cylinder, it will result in air leakage. MVGQ For basic style, the port position in a head cover is available either perpendicular to the axis or in-line with the cylinder axis.