Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.

VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5

Indication unit The unit of pressure used in the display. 11 - NO. ZQ-OM01501 No. Terms Meaning K Key lock function Function that prevents changes to the settings of the Pressure switch (disables button operation). M Manual pressure setup without using auto preset. This term is used to distinguish between manual and auto preset pressure setup.

ZQ-OM01601 // ZQ-ZSV 2 9 10 11 14 14 15 16 16 19 19 19 F0 21 F1 OUT1 22 F2 OUT2 24 F3 26 F4 27 F6 29 F11 30 F80 31 F81 32 F90 33 F96 35 F98 36 F99 38 39 42 43 44 50 51 51 1 - *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.

No.PS-OMU0002CN-D // ZSE20A(F) ISE20A 2 8 10 11 15 15 17 19 [] 22 23 3 24 26 28 28 28 F0 30 F1 OUT1 31 F2 OUT2 34 F3 36 F4 37 F5 FUNC 39 F6 41 F10 42 F11 48 F80 49 F81 50 F82 52 F90 53 F96 55 F97 56 F98 58 F99 60 61 65 65 66 75 75 78 -1No.PS-OMU0002CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO

No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO

No.PS-OMS0006CN-G / / ZSE20(F) ISE20 2 8 10 11 14 14 16 18 [] 20 21 3 22 24 26 26 26 F0 28 F1 OUT1 29 F3 32 F4 33 F6 35 F10 36 F11 41 F80 42 F81 43 F82 45 F90 46 F98 48 F99 49 50 54 54 55 62 62 64 -1No.PS-OMS0006CN-G *1) (ISO/IEC)(JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules

Note 6) Refer to P/A catalog CAT.ES100-42 for detailed specifications and instructions of digital pressure switch.

No.PS-OMU0003-D PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE20A(F) ISE20A Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 15 Installation 15 Piping 17 Wiring 19 Outline of Settings [Measurement mode] 22 Pressure Setting 23 3 Step Setting Mode 24 Simple

No.PS-OMU0006-D PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE20B(F) ISE20B Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 15 Installation 15 Piping 17 Wiring 20 Outline of Settings [Measurement mode] 23 Pressure Setting 24 3 Step Setting Mode 25 Simple

No.PS-OMS0007-H PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE20(F) ISE20 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Piping 16 Wiring 18 Outline of Settings [Measurement mode] 20 Pressure Setting 21 3 Step Setting Mode 22 Simple

Gun Type Ionizer IZG10 Series IZS40/41/42 IZT40/41(-L)/ 42(-L)/43(-L) IZN10E IZF IZG10 ZVB IZD10/IZE11 IZH10 Antistatic Equipment *1 Lightweight 200 g Only *1 Body weight Lighting LED Reduced operating force Easy to hold grip Blow setting function p. 179 Select from continuous blow or pulse blow.

Manifold Specifications for 41 and 42 Type Manifold Specifications for 41 and 42 Type SS5Y5-41 SS5Y5-42 SS5Y7-42 Port size Flow characteristics Model 52-SY740 52-SY540 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) 1,5,3 Model Applicable valve 4,2 (A,B) (P ,EA,EB) b Cv c[dm3/(sbar)] c[dm3/(sbar)] Single base / B mounting Manifold style b Cv SS5Y5-41 1 (SUP) / 3/5 (EXH) Common SUP / Common EXH 1/4

Parameter definition and setting 42 Hardware Configuration 55 GSD file and icon 55 Configuration layout 55 SIEMENS PLC S7TM connection method 56 Parameter setting at PLC 59 I/O Map 61 Diagnostic 62 Accessories 70 -2No.EX-OMN0028-B Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

If the security code is forgotten 42 Troubleshooting 43 Specification 50 Specifications 50 Dimensions 52 -1No.PS-OMM0003-J Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

58 45 30 32 9 +0.2 +0.1 23 2 34H9 +0.062 depth 4 0 27 30 4 x M6 x 1 thread depth 7 Rc 1/8 (G1/8, NPT1/8) (Finger closing port) 45 (Thread for mounting attachment) Auto Switch Mounting Groove Dimensions 32.9 20 20 51 11 11 Rc 1/8 (G1/8, NPT1/8) (Finger opening port) 25 13 MHW2-32D1 5 Right angle finger type 6.45 5.5 44 21 14 20 7 18 27 4 x M6 x 1 through (Thread for mounting attachment) 34

1, @2 and @6 each. 12 MXY12-PS 8-9-11 11 Series MXY Dimensions 2-M5 x 0.8 Piping port J + Stroke Same in case of the type of centralized piping on one side without switch rail ( ) JH Piping port (Plug: M-5P) 2-M5 x 0.8 (Plug: M-5P) 2-M5 x 0.8 Piping port FL 21 21 FH 2-M thread depth MM +0.03 0 Width across flats MB (lock plate fixing bolt) R 4-M thread depth MM PR RL PR +0.03 0 MA (Stroke

OPTIONAL ASSEMBLY 11 7. DIMENSIONS 12~13 Pressure Relief 3 Port Valve With Locking Holes Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

11 Series IR1000/2000/3000 Series IR3000 Flow Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.